5.5.2
Charging the Battery in the Non-Ex Base Station
Charge the battery before using it for the first time.
The charging process takes 8 hours.
A charging station for charging the hand scanner is available too.
It is identical to the base station but without radio connection.
Work steps:
1.
Use the non-Ex base station only outside the hazardous area.
2.
It is important to keep the battery sufficiently charged so that the bluetooth hand
scanner does not lose the radio connection to the base station.
3.
Plug the power supply into the socket.
4.
Insert the mains lead into the DC input in the non-Ex base station. Acoustic signals
from the non-Ex base station will confirm the connection to voltage.
The "POWER"
LED on the non-Ex base station will light up in blue once.
The "POWER" LED will
light up in a steady blue on the non-Ex charging station.
5.
Insert the bhand scanner with the inserted battery into the base station by first
pushing in the bottom (see illustration, step 1) and then the hand scanner head (see
illustration, step 2).
6.
If the battery is not fully charged, the "STATUS" LED on the hand scanner will light up
in a steady red.
7.
If the battery is fully charged, the "STATUS" LED on the hand scanner will flash in
green at regular intervals.
Base station, without cable, non-Ex
03-9849-0063
Charging station without bluetooth function, non-Ex
03-9849-0064
DC 5 V power supply, for base station/charging station, non-Ex 03-9911-0039
For more information, see documentation from Sick.