background image

Recessed Ceiling or Recessed Wall Mount

1. Using a screwdriver, carefully open the front cover. 

(Fig. 6)

2. Remove the J-box cover from the included J-box and 

punch out the knockout from the J-box cover.

3. Secure the J-box to the top of the fixture using screws.

4. Route wires through the J-box and the J-box cover.

5. Remove the end cap with the test switch and LED 

indicator. (Fig. 7)

6. Remove the test switch, LED indicator, and bushing 

from the end cap, then route the test switch and LED 

indicator wires out of the end cap, as shown.

7. Resecure the end cap to the fixture.

8. Install the test switch and LED indicator bushing in the 

trimplate. (Fig. 8)

9. Position the recessed kit between joists, making sure 

the hanger bars are positioned correctly. Use the 

adjusting screws to guide the hanger bars. The bottom 

of the recessed housing should be level with the 

bottom of the joist. Secure temporarily by hammering in 

the nail-in tabs, then permanently with nails. (Fig. 9)

10. Adjust the height of the recessed kit as needed, then 

tighten all screws to secure the adjusting bracket and 

hanger bars.

11. Make electrical connections; see 

Electrical 

Connections

 section. (Fig. 10)

12. Follow steps 7-10 in the 

Surface Ceiling or Surface 

Wall Mount

 section.

Fig. 6

Fig. 7

Fig. 8

Fig. 9

Fig. 10

AC Wires

Switch Connector

Switch Nut

Screws

Test Switch

Bushing

End Cap (Test Switch Side)

LED Indicator

LED 

Indicator

Switch

Wire

Trimplate

Test Switch

LED Bushing

Hanger Bars

Joists

Adjust Screws

Tighten Screws after Positioning

10070149 

R

EV 4 - 04/22

3

800-533-3948 www.barronltg.com

NY900U Series

Installation Instructions

Содержание Exitronix NY900U Series

Страница 1: ... locations and at heights where it will not be readily subjected to tampering by unauthorized personnel The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition Any modification or use of non original components will void the warranty and product liability Do not use this equipment for other than intended use Allow battery to charge for 24 hours before first...

Страница 2: ... the correct orientation Fig 3 9 Peel off the appropriate chevrons from the EXIT panel as desired 10 Snap the front cover back into place 11 Rotate the EXIT panel as needed for the mounting application The EXIT panel can rotate from 0 to 180 Fig 4 End Mount 1 Follow steps 1 and 2 in the Surface Ceiling or Surface Wall Mount section 2 Remove the hole plug from the end cap 3 Secure the canopy to the...

Страница 3: ...ure the hanger bars are positioned correctly Use the adjusting screws to guide the hanger bars The bottom of the recessed housing should be level with the bottom of the joist Secure temporarily by hammering in the nail in tabs then permanently with nails Fig 9 10 Adjust the height of the recessed kit as needed then tighten all screws to secure the adjusting bracket and hanger bars 11 Make electric...

Страница 4: ...nt applications rotate the EXIT panel 90 Fig 12 Electrical Connections All electrical connections should be made inside the J box Make electrical connections as follows Fig 13 120VAC 277VAC White Common White Common Black 120VAC Orange 277VAC Green Ground Green Ground Note Cap unused leads to prevent shorting Fig 11 Test Switch Connector LED Indicator Test Switch Trimplate Trimplate Screws Fig 12 ...

Страница 5: ... the unit is in battery mode Refer to the Test Button Feature section below for manual test details A red LED indicates whenever the Self diagnostic system has detected a fault condition Refer to the chart below to determine the fault condition Test Button Feature MANUAL TEST Pressing the test button will switch the unit into battery mode for a set amount of time The desired length of the test is ...

Отзывы: