5
• Do not use corrosive products to clean the floor or shelf be
-
neath the appliance.
• Do not wash the body or flame spreader of the hob burners
in the dishwasher.
3 SAFETY AND CONTROL DEVICES
PRESSURE SWITCH
• The appliance is fitted with a pressure switch which stops
activation of heating in the event the water in the well falls
below the safety level ( approx. 12 cm ). To restore heating
in the event the pressure switch is tripped, top up the water
level to the minimum mark visible on the rear wall of the well.
4 DISPOSAL OF PACKAGING AND THE APPLIANCE
PACKAGING
The packaging is made using environmentally friendly mate-
rials. The plastic recyclable components are:
•
the transparent cover, the bags containing the instructions
manual and nozzles ( made of polyethylene - PE.).
•
the straps (in polypropylene - PP).
APPLIANCE
The appliance is manufactured 90% from recyclable metals
(stainless steel, aluminum sheet, copper.... ).
The appliance must be scrapped in compliance with current
regulations governing such disposal.
•
It must be disposed of properly.
•
Make the appliance unusable before scrapping.
5 RISKS DUE TO NOISE
•
As regards airborne acoustical noise emissions, the A-
weighted sound pressure level is below 70 dB(A).
INSTRUCTIONS FOR INSTALLATION
REMINDERS FOR THE INSTALLER
The manufacturer will not be liable for any damage or in-
jury resulting from failure to observe the following rules.
•
Read this manual carefully. It provides important information
for safe installation, use and maintenance of the appliance.
• Installation, conversion to a different type of gas and applian
-
ce maintenance must be carried out by qualified technicians
authorized by the manufacturer, in compliance with current
safety standards and the instructions given in this manual.
• Identify the specific appliance model. The model number is
detailed on the packaging and on the appliance data plate.
•
The appliance must be installed in a well-ventilated room.
•
Do not obstruct any air vents or drains present on the ap-
pliance.
•
Do not tamper with appliance components.
6 REFERENCE STANDARDS AND LAWS
Install the appliance in compliance with current safety regula-
tions.
Install the appliance in compliance with current regulations.
7 HANDLING
The packaging is marked with warning symbols that indicate
the precautions to be taken when handling the appliance to
avoid damage.The appliance must only be handledusing su-
itable equipment. If lifting equipment is used, such as forklift
trucks or similar, make sure that the appliance is in a stable
position.
8 UNPACKING
Check the state of the packaging and in the event of damage,
ask the delivery person to inspect the goods.
•
Remove the packaging.
• Remove the protective film from the exterior and interior pa
-
nels. Use a suitable solvent to remove any residual adhesive
from the panels.
9 POSITIONING
•
The overall dimensions of the appliance and the position of
connections are given on the installation diagram at the start
of this manual.
•
The appliance can be installed singly or in combination with
other appliances in the same product range.
•
The appliance is not suitable for integrated installation.
•
Position the appliance at least 10 cm from adjacent walls.
This distance can be reduced in the presence of non-combu-
stible walls or heat-insulated walls.
•
Level the appliance by means of the height-adjustable feet.
•
The countertop appliance weighing less than 40kg, where
installed singly, must be secured using the flanged feet pro
-
vided.
APPLIANCE ASSEMBLY WITH BASE, BRIDGE, AND CAN-
TILEVER SOLUTIONS
Follow the instructions provided with the type of support utili-
zed.
FIXING THE APPLIANCE TO THE FLOOR
Appliances of 40cms in width installed alone must be fixed to
the floor. Use the flanged feet provided.
JOINING APPLIANCES TOGETHER IN LINE
•
Pull out the control knobs , remove control panel.
•
Place the appliances side by side and adjust the tops to the
same height.
•
Unite the appliances using the screws.
10 FUMES EXHAUST SYSTEM
Provide a fumes exhaust system based on the "Type" of ap-
pliance.The "Type" is stated on the appliance dataplate.
APPLIANCE TYPE "A1"
•
Position the "A1" type appliance below an extractor hood to
ensure smoke and fumes generated by cooking are removed.
APPLIANCE TYPE "B21"
•
Position the "B21" type appliance below an extractor hood.
APPLIANCE TYPE "B11"
• Fit the "B11" type appliance with a suitable flue, available
from the appliance manufacturer. Follow the assembly in-
structions provided with the flue.
• Connect the flue to a 150/155 mm diameter hose, heat resi
-
stant to 300°C.
• Vent to the outside or into an efficient flue. The hose length
must not exceed 3 metres.
11 CONNECTIONS
The position and dimensions of connections are given in the
installation diagram at the start of this manual.