background image

20

4SE & 4SEU Pump Series

36 

001348 

 

t

 

Shim .031” x 1.5” O.D. 

(Impeller) 

 

37 

001349 

 

t

 

Shim .010” x 1.5” O.D. 

(Impeller) 

 

39 

036803 

 

 

Soc. Hd. Cap Screw 

1/4-20 x 3/4” lg Stainless 

41 

036852 

 

ªt

  Gasket   

 

42 

056668 

 

ªt

  Square-Ring 

 

 

43 

022879 

 

 

Diaphragm Clamp Ring 

 

 

44 

002203 

 

 

Cap Screw 

 

1/4-20 x 7/8” lg Steel 

 

46 

039485 

 

ªt

  Shaft Seal (Both Ends) 

Carbon/Ceramic/Buna-N (STD) 

 

 

060817 

 

 

(Pump End) 

 

Tungsten/Carbide/Buna-N 

 

 

060817SC  

 

 

(Both Ends) 

 

Tungsten/Carbide/Buna-N 

47 

039332 

 

t

 

Ball Bearing 

 

 

53 

016405 

 

t

 

Insulator 

 

 

 

030149 

 

t

 

Insulator 

(7.5HP, 1PH & 15HP ONLY) 

54 

052761 

 

 

Wear Plate 

4SEU’s ONLY 

 

55 

1-130-1 

 

 

Cap Screw 

5/16-18 x 1.0” lg, Stainless 

56 

20-2-1 

 

 

Lockwasher 

5/16 Stainless

TABLE 2 - CORD SETS

MODELS/

LENGTHS

ITEM #10

Moist. & Temp (STD)

Except; 7.5Hp, 1Ph & 3Ph, 230 & 

460 V, 1750RPM

11.3 & 15Hp, 3Ph, 230 & 460V, 

1750RPM

ITEM #10

Moist. & Temp (STD)

For; 7.5Hp, 1Ph, 1750RPM

15Hp, 3Ph, 1750RPM

15Hp, 3Ph, 230 & 460V, 

3450RPM

ONLY

ITEM #10

Moist. & Temp (STD)

For; 7.5 & 11.3Hp, 3Ph, 230 

& 460V.

and 15Hp, 575V

ONLY

40 Ft. (STD)

072448XE

111160XE

072700XE

50 Ft.

072448XF

111160XF

072700XF

75 Ft.

072448XJ

111160XJ

072700XJ

100 Ft.

072448XL

111160XL

072700XL

150 Ft.

072448XS

111160XS

072700XS

Содержание 4SE-HL Series

Страница 1: ...reserves the right to change product without prior written noti cation 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773...

Страница 2: ...8 20 CROSS SECTION 3450RPM Fig 12 21 EXPLODED VIEW 3450RPM Fig 13 22 PARTS LIST 23 24 RETURNED GOODS POLICY 25 WARRANT START UP REPORT WARRANTY REGISTRATION SPECIAL TOOLS AND EQUIPMENT INSULATION TEST...

Страница 3: ...insert ngers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety d...

Страница 4: ...ge Induction Winding Class F Class H Rated Magnet Wire Service Factor 1 15 SINGLE PHASE Capacitor Start Capacitor Run Requires BARNES Starter Panel Which includes capacitors and overload protection TH...

Страница 5: ...Cage Induction Winding Class F Class H Rated Magnet Wire Service Factor 1 15 SINGLE PHASE Capacitor Start Capacitor Run Requires BARNES Starter Panel Which includes capacitors and overload protection...

Страница 6: ...nits are self contained and are recommended for use in a sump lift station or basin This pump is designed to pump sewage ef uent or other nonexplosive or noncorrosive wastewater and shall NOT be insta...

Страница 7: ...e situations may induce a false signal in the moisture detecting circuit If none of the above test prove conclusive the pump s should be pulled and the source of the failure identi ed and repaired IF...

Страница 8: ...0 7 32 0 10 4 SOW 0 75 4SE11364L 11 3 200 3 1750 B 32 2 109 5 8 4 SOW 0 83 0 35 4SE11334L 11 3 230 3 1750 D 28 0 126 0 8 4 SOW 0 83 0 43 4SE11344L 11 3 460 3 1750 D 14 0 63 0 8 4 SOW 0 83 1 72 4SE1135...

Страница 9: ...n oil into a clean dry container In separate container drain seal chamber by removing pipe plug 22 2 Check oil for contamination using an oil tester with a range to 30 Kilovolts breakdown 3 If oil is...

Страница 10: ...ed in paragraph F 2 1 and disassemble seal plate and shaft seal as outlined in paragraph F 4 1 Drain oil from motor as outlined in paragraph F 1 3 Position unit upright using blocks to avoid resting u...

Страница 11: ...46 remove impeller 28 as outlined in paragraph F 2 1 Drain oil from seal chamber as outlined in paragraph F 1 3 Remove cap screws 8 and lifting strap 7 Set unit upside down on blocks to avoid damaging...

Страница 12: ...pusher until retainer engages spring 46C and spring is compressed slightly Make sure spring 46C is properly engaged in both retainers Slide seal plate 25 over shaft onto bearing bracket 21 being care...

Страница 13: ...8 White 3 9 T4 T5 T6 Together THREE PHASE 480 600 VOLT AC Power Cable Motor Lead Number Green Ground Green Black 1 Red 2 White 3 T4 T7 Together T5 T8 Together T6 T9 Together MOISTURE AND TEMPERATURE S...

Страница 14: ...e design con guration This number is used for ordering and obtaining information G 3 MODEL NUMBER This designation consists of numbers and letters which repre sent the discharge size series horsepower...

Страница 15: ...impeller for freedom of operation security and condition Clean impeller and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set...

Страница 16: ...16 FIGURE 10 4SEU Models ONLY 4SE 4SEU Pump Series...

Страница 17: ...17 FIGURE 11 4SE 4SEU Pump Series...

Страница 18: ...8 2 1 68 1 Cap Screw 1 2 13 x 1 1 4 lg Stainless 10 1 See Table 2 Conduit Box Cable Assembly 10a 1 Power Cable Not Sold Separately 10b 1 051447 Gland Nut 1 072559 Gland Nut For 7 5 11 3Hp 3Ph 15Hp 57...

Страница 19: ...1150RPM 8 75 Dia 084894TS 084895TS 8 62 Dia 084894TT 084895TT 15HP 1750RPM 8 50 Dia 084894TU 084895TU 8 38 Dia 084894TV 084895TV 8 25 Dia 084894TW 084895TW 8 12 Dia 084894TX 084895TX 11 3HP 1750RPM 8...

Страница 20: ...ring 53 5 016405 t Insulator 5 030149 t Insulator 7 5HP 1PH 15HP ONLY 54 1 052761 Wear Plate 4SEU s ONLY 55 4 1 130 1 Cap Screw 5 16 18 x 1 0 lg Stainless 56 4 20 2 1 Lockwasher 5 16 Stainless TABLE 2...

Страница 21: ...21 4SE HL High Ef ciency Pump Series FIGURE 12...

Страница 22: ...22 4SE HL High Ef ciency Pump Series FIGURE 13...

Страница 23: ...on Ring 2 071431A Friction Ring For 7 5 11 3Hp 3Ph 15Hp 575V 2 110929 Friction Ring For 7 5HP 1PH 15HP ONLY 10d 1 051452 Grommet 1 071430A Grommet For 7 5 11 3Hp 3Ph 15Hp 575V 1 110928 Grommet For 7 5...

Страница 24: ...ess 39 2 036803 Soc Hd Cap Screw 1 4 20 x 3 4 lg Stainless 41 1 036852 t Gasket 42 1 056668 t Square Ring 43 1 022879 Diaphragm Clamp Ring 44 4 002203 Cap Screw 1 4 20 x 7 8 lg Steel 46 1 039485 t Sha...

Страница 25: ...s between the results of eld testing conducted by or for user and laboratory tests corrected for eld performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FR...

Страница 26: ...nt To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by t...

Страница 27: ...O___ Type _________________________________ Number and size of short circuit device s ___________ Amp rating ___________________ Overload Type _____________ Size ______________ Amp rating ____________...

Страница 28: ...rols installed away from turbulence YES___ NO___ Is level control operating properly YES___ NO___ Is pump fully submerged during operation YES___ NO___ Follow up Corrective Action Required YES___ NO__...

Отзывы: