background image

23

PARTS KITS

Seal Repair Kit...........P/N-085203
Overhaul Kit...............P/N-127010
Seal Tool Kit...............P/N-085737
Pressure Gauge Kit...P/N-085343

PARTS LIST - Standard

ITEM 

QTY 

PART NO. 

 

 

DESCRIPTION   

 

 

072688MA 

 

 

Motor - 4SE4526HL

 

 

072689MA 

 

 

 

4SE4596HL, 46HL

 

 

092819 

 

 

 

4SE4556HL

 

 

072690MA 

 

 

 

4SE7596HL, 46HL

 

 

092820 

 

 

 

4SE7556HL

 

 

072694MA 

 

 

 

4SE7524HL

 

 

072695MA 

 

 

 

4SE7534HL, 44HL

 

 

091726 

 

 

 

4SE7554HL

 

 

072696MA 

 

 

 

4SE11334HL, 44HL

 

 

091743 

 

 

 

4SE11354HL

 

 

072697MA 

 

 

 

4SE15034HL, 44HL

 

 

091744 

 

 

 

4SE15054HL 

 

 

053030 

 

 

Motor Housing 

 

 

 

039734 

 

t

 

Ball Bearing 

 

 

 

070624 

 

 

Pipe Closure 

 

 

 

070623 

 

 

Pressure Relief Valve 

 

 

1-34-1 

 

 

Cap Screw,  

 

3/8-16 x 1” lg Stainless 

 

036863A 

 

 

S.S. Lifting Strap  

 

 

1-68-1 

 

 

Cap Screw,  

 

1/2-13 x 1-1/4” lg Stainless 

10 

See Table 2 

 

 

Conduit Box & Cable Assembly 

 

10a 

----- 

 

 

Power Cable  

 

 (Not Sold Separately)

10b 

051447 

 

Gland Nut 

 

 

 

 

072559 

 

Gland Nut,  

 

(For 7.5 & 11.3Hp 3Ph & 15Hp 575V) 

 

052259 

 

Gland Nut 

 

(For 7.5HP, 1PH & 15HP ONLY) 

10c 

051450 

 

Friction Ring 

 

 

 

 

071431A 

 

Friction Ring 

 

(For 7.5 & 11.3Hp 3Ph & 15Hp 575V) 

 

110929 

 

 

Friction Ring 

 

(For 7.5HP, 1PH & 15HP ONLY) 

10d 

051452 

 

Grommet 

 

 

 

071430A 

 

Grommet 

 

(For 7.5 & 11.3Hp 3Ph & 15Hp 575V) 

 

110928 

 

 

Grommet 

 

(For 7.5HP, 1PH & 15HP ONLY) 

10e 

----- 

 

Control Cable 

 

(Not Sold Separately)

10f 

051448 

 

Gland Nut 

 

 

 

10g 

021531 

 

Friction Ring 

 

 

 

10h 

066871 

 

*

t

  Grommet 

 

 

 

10J 

030169 

 

Ground Screw 

 

10-32 x 5/8 Lg Stainless 

 

11 

051937 

 

ªt

  Square Ring 

 

 

12 

016406 

 

t

 

Connector  

 

 

 

 

030148 

 

t

 

Connector 

 

(7.5HP,1PH & 15HP ONLY) 

13 

2.5 Gal  029034 

 

 

Oil - Motor Housing 

 

 

 

35 oz.   

 

 

Oil - Seal Cavity

14 

5-32-6 

 

 

Machine Screw   

6-32 x 1/4 Cad. Plt. Steel 

15 

052563 

 

 

Lockwasher 

 

No. 6 Steel 

 

16 

051487 

 

t

 

Moisture Sensor Wire 

 

 

17 

052990 

 

t

 

Connector 

 

(Sensor Wires) 

 

18 

039383 

 

 

Electrode 

 

 

19 

1-38-1 

 

 

Hex Hd Screw 

 

3/8-16 x 1.50” lg Stainless 

20 

018927 

 

 

Nut 

 

 

3/8-16 Stainless   

21 

039030 

 

 

Bearing Bracket   

 

22 

003202 

 

 

Pipe Plug 

 

 

24 

033824 

 

 

Stud 

 

 

3/8-16 x 2” lg Stainless 

25 

039038 

 

 

Seal Plate 

 

 

26 

082213 

 

 

Volute   

27 

039934 

 

 

Caplug   

 

28 

082217 

 

 

9.00” Dia. - 7.5,1150 & 15,1750 

4SE-HL (High Effi ciency) Pump Series

(

ª

) 11, 32, 41, 42, 46

(

t

) 3, 11, 12, 16, 17, 32, 33, 34, 41, 42, 46, 47, 54

Содержание 4SE-HL Series

Страница 1: ...reserves the right to change product without prior written noti cation 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773...

Страница 2: ...8 20 CROSS SECTION 3450RPM Fig 12 21 EXPLODED VIEW 3450RPM Fig 13 22 PARTS LIST 23 24 RETURNED GOODS POLICY 25 WARRANT START UP REPORT WARRANTY REGISTRATION SPECIAL TOOLS AND EQUIPMENT INSULATION TEST...

Страница 3: ...insert ngers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety d...

Страница 4: ...ge Induction Winding Class F Class H Rated Magnet Wire Service Factor 1 15 SINGLE PHASE Capacitor Start Capacitor Run Requires BARNES Starter Panel Which includes capacitors and overload protection TH...

Страница 5: ...Cage Induction Winding Class F Class H Rated Magnet Wire Service Factor 1 15 SINGLE PHASE Capacitor Start Capacitor Run Requires BARNES Starter Panel Which includes capacitors and overload protection...

Страница 6: ...nits are self contained and are recommended for use in a sump lift station or basin This pump is designed to pump sewage ef uent or other nonexplosive or noncorrosive wastewater and shall NOT be insta...

Страница 7: ...e situations may induce a false signal in the moisture detecting circuit If none of the above test prove conclusive the pump s should be pulled and the source of the failure identi ed and repaired IF...

Страница 8: ...0 7 32 0 10 4 SOW 0 75 4SE11364L 11 3 200 3 1750 B 32 2 109 5 8 4 SOW 0 83 0 35 4SE11334L 11 3 230 3 1750 D 28 0 126 0 8 4 SOW 0 83 0 43 4SE11344L 11 3 460 3 1750 D 14 0 63 0 8 4 SOW 0 83 1 72 4SE1135...

Страница 9: ...n oil into a clean dry container In separate container drain seal chamber by removing pipe plug 22 2 Check oil for contamination using an oil tester with a range to 30 Kilovolts breakdown 3 If oil is...

Страница 10: ...ed in paragraph F 2 1 and disassemble seal plate and shaft seal as outlined in paragraph F 4 1 Drain oil from motor as outlined in paragraph F 1 3 Position unit upright using blocks to avoid resting u...

Страница 11: ...46 remove impeller 28 as outlined in paragraph F 2 1 Drain oil from seal chamber as outlined in paragraph F 1 3 Remove cap screws 8 and lifting strap 7 Set unit upside down on blocks to avoid damaging...

Страница 12: ...pusher until retainer engages spring 46C and spring is compressed slightly Make sure spring 46C is properly engaged in both retainers Slide seal plate 25 over shaft onto bearing bracket 21 being care...

Страница 13: ...8 White 3 9 T4 T5 T6 Together THREE PHASE 480 600 VOLT AC Power Cable Motor Lead Number Green Ground Green Black 1 Red 2 White 3 T4 T7 Together T5 T8 Together T6 T9 Together MOISTURE AND TEMPERATURE S...

Страница 14: ...e design con guration This number is used for ordering and obtaining information G 3 MODEL NUMBER This designation consists of numbers and letters which repre sent the discharge size series horsepower...

Страница 15: ...impeller for freedom of operation security and condition Clean impeller and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set...

Страница 16: ...16 FIGURE 10 4SEU Models ONLY 4SE 4SEU Pump Series...

Страница 17: ...17 FIGURE 11 4SE 4SEU Pump Series...

Страница 18: ...8 2 1 68 1 Cap Screw 1 2 13 x 1 1 4 lg Stainless 10 1 See Table 2 Conduit Box Cable Assembly 10a 1 Power Cable Not Sold Separately 10b 1 051447 Gland Nut 1 072559 Gland Nut For 7 5 11 3Hp 3Ph 15Hp 57...

Страница 19: ...1150RPM 8 75 Dia 084894TS 084895TS 8 62 Dia 084894TT 084895TT 15HP 1750RPM 8 50 Dia 084894TU 084895TU 8 38 Dia 084894TV 084895TV 8 25 Dia 084894TW 084895TW 8 12 Dia 084894TX 084895TX 11 3HP 1750RPM 8...

Страница 20: ...ring 53 5 016405 t Insulator 5 030149 t Insulator 7 5HP 1PH 15HP ONLY 54 1 052761 Wear Plate 4SEU s ONLY 55 4 1 130 1 Cap Screw 5 16 18 x 1 0 lg Stainless 56 4 20 2 1 Lockwasher 5 16 Stainless TABLE 2...

Страница 21: ...21 4SE HL High Ef ciency Pump Series FIGURE 12...

Страница 22: ...22 4SE HL High Ef ciency Pump Series FIGURE 13...

Страница 23: ...on Ring 2 071431A Friction Ring For 7 5 11 3Hp 3Ph 15Hp 575V 2 110929 Friction Ring For 7 5HP 1PH 15HP ONLY 10d 1 051452 Grommet 1 071430A Grommet For 7 5 11 3Hp 3Ph 15Hp 575V 1 110928 Grommet For 7 5...

Страница 24: ...ess 39 2 036803 Soc Hd Cap Screw 1 4 20 x 3 4 lg Stainless 41 1 036852 t Gasket 42 1 056668 t Square Ring 43 1 022879 Diaphragm Clamp Ring 44 4 002203 Cap Screw 1 4 20 x 7 8 lg Steel 46 1 039485 t Sha...

Страница 25: ...s between the results of eld testing conducted by or for user and laboratory tests corrected for eld performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FR...

Страница 26: ...nt To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by t...

Страница 27: ...O___ Type _________________________________ Number and size of short circuit device s ___________ Amp rating ___________________ Overload Type _____________ Size ______________ Amp rating ____________...

Страница 28: ...rols installed away from turbulence YES___ NO___ Is level control operating properly YES___ NO___ Is pump fully submerged during operation YES___ NO___ Follow up Corrective Action Required YES___ NO__...

Отзывы: