Please Read This Before Installing Or Operating Pump. 
This information is provided for 

SAFETY and to PREVENT 

EQUIPMENT PROBLEMS

. To help recognize this information, 

observe the following symbols:

IMPORTANT!

 Warns about hazards that can result 

in personal injury or Indicates factors concerned with 
assembly, installation, operation, or maintenance which 
could result in damage to the machine or equipment if 
ignored.

CAUTION !

 Warns about hazards that can or will cause minor 

personal injury or property damage if ignored. Used with symbols 
below.

WARNING !

  Warns about hazards that can or will cause serious 

personal injury, death, or major property damage if ignored. Used 
with symbols below.

Only qualifi ed personnel should install, operate and repair 
pump. Any wiring of pumps should be performed by a qualifi ed 
electrician.  

WARNING ! -

 To reduce risk of electrical shock, pumps 

and control panels must be properly grounded in 
accordance with the National Electric Code (NEC) or the 
Canadian Electrical Code (CEC) and all applicable state, 
province, local codes and ordinances. 

WARNING! -

 To reduce risk of electrical shock, always 

disconnect the pump from the power source before 
handling or servicing. Lock out power and tag.

WARNING!

 Operation against a closed 

discharge valve will cause premature bearing 
and seal failure on any pump, and on end 
suction and self priming pump the heat build 

may cause the generation of steam with resulting dangerous 
pressures. It is recommended that a high case temperature 
switch or pressure relief valve be installed on the pump body.

CAUTION !

 Never operate a pump with a plug-in  type 

power cord without a ground fault  circuit interrupter.

CAUTION! 

Pumps build up heat and pressure 

during operation-allow time for pumps to cool 
before handling or servicing. 

WARNING!

 - 

DO NOT

 pump hazardous materials 

(fl ammable, caustic, etc.) unless the pump is specifi cally 
designed and designated to handle them.

Do not block or restrict discharge hose, as discharge 
hose may whip under pressure. 

WARNING! - DO NOT

 wear loose clothing that may 

become entangled in the impeller or other moving parts. 

WARNING! - 

Keep clear of suction and discharge 

openings. 

DO NOT

 insert fi ngers in pump with power 

connected.

Always wear eye protection when working on pumps.

Make sure lifting handles are securely fastened each 
time before lifting. 

DO NOT

 operate pump without 

safety devices in place. Always replace safety devices 
that have been removed during service or repair. 
Secure the pump in its operating position so it can not 
tip over, fall or slide.

DO NOT

 exceed manufacturers recommendation for 

maximum performance, as this could cause the motor 
to overheat.

DO NOT

 remove cord and strain relief. Do not connect 

conduit to pump.

WARNING!

 Cable should be protected at all times to 

avoid punctures, cut, bruises and abrasions - inspect 
frequently. Never handle connected power cords with 
wet hands.

WARNING!

 To reduce risk of electrical shock, all wiring 

and junction connections should be made per the NEC 
or CEC and applicable state or province and local 
codes. Requirements may vary depending on usage 
and location.

WARNING!

 Submersible Pumps are not approved for 

use in swimming pools, recreational water installations, 
decorative fountains or any installation where human 
contact with the pumped fl uid is common.

WARNING! 

Products Returned Must Be Cleaned, 

Sanitized, Or Decontaminated As Necessary Prior 
To Shipment, To Insure That Employees Will Not Be 
Exposed To Health Hazards In Handling Said Material. 
All Applicable Laws And Regulations Shall Apply.

 

Bronze/brass and bronze/brass fi tted pumps may 
contain lead levels higher than considered safe for 
potable water systems. Lead is known to cause cancer 
and birth defects or other reproductive harm. Various 
government agencies have determined that leaded 
copper alloys should not be used in potable water 
applications. For non-leaded copper alloy materials of 
construction, please contact factory. 

IMPORTANT! -

 Crane Pumps & Systems, Inc. is not 

responsible for losses, injury, or death resulting from a 
failure to observe these safety precautions, misuse or 
abuse of pumps or equipment.

SAFETY FIRST!

Hazardous fl uids can 
cause fi re or explo-
sions, burnes or death 
could result.

Extremely hot - Severe 
burnes can occur on contact.

Biohazard can cause 
serious personal injury.

Hazardous fl uids can Hazard-
ous pressure, eruptions or ex-
plosions could cause personal 
injury or property damage.

Rotating machinery
Amputation or severe 
laceration can result.

Hazardous voltage can 
shock, burn or cause death.

Содержание 4SE-HL Series

Страница 1: ...reserves the right to change product without prior written noti cation 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773...

Страница 2: ...8 20 CROSS SECTION 3450RPM Fig 12 21 EXPLODED VIEW 3450RPM Fig 13 22 PARTS LIST 23 24 RETURNED GOODS POLICY 25 WARRANT START UP REPORT WARRANTY REGISTRATION SPECIAL TOOLS AND EQUIPMENT INSULATION TEST...

Страница 3: ...insert ngers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety d...

Страница 4: ...ge Induction Winding Class F Class H Rated Magnet Wire Service Factor 1 15 SINGLE PHASE Capacitor Start Capacitor Run Requires BARNES Starter Panel Which includes capacitors and overload protection TH...

Страница 5: ...Cage Induction Winding Class F Class H Rated Magnet Wire Service Factor 1 15 SINGLE PHASE Capacitor Start Capacitor Run Requires BARNES Starter Panel Which includes capacitors and overload protection...

Страница 6: ...nits are self contained and are recommended for use in a sump lift station or basin This pump is designed to pump sewage ef uent or other nonexplosive or noncorrosive wastewater and shall NOT be insta...

Страница 7: ...e situations may induce a false signal in the moisture detecting circuit If none of the above test prove conclusive the pump s should be pulled and the source of the failure identi ed and repaired IF...

Страница 8: ...0 7 32 0 10 4 SOW 0 75 4SE11364L 11 3 200 3 1750 B 32 2 109 5 8 4 SOW 0 83 0 35 4SE11334L 11 3 230 3 1750 D 28 0 126 0 8 4 SOW 0 83 0 43 4SE11344L 11 3 460 3 1750 D 14 0 63 0 8 4 SOW 0 83 1 72 4SE1135...

Страница 9: ...n oil into a clean dry container In separate container drain seal chamber by removing pipe plug 22 2 Check oil for contamination using an oil tester with a range to 30 Kilovolts breakdown 3 If oil is...

Страница 10: ...ed in paragraph F 2 1 and disassemble seal plate and shaft seal as outlined in paragraph F 4 1 Drain oil from motor as outlined in paragraph F 1 3 Position unit upright using blocks to avoid resting u...

Страница 11: ...46 remove impeller 28 as outlined in paragraph F 2 1 Drain oil from seal chamber as outlined in paragraph F 1 3 Remove cap screws 8 and lifting strap 7 Set unit upside down on blocks to avoid damaging...

Страница 12: ...pusher until retainer engages spring 46C and spring is compressed slightly Make sure spring 46C is properly engaged in both retainers Slide seal plate 25 over shaft onto bearing bracket 21 being care...

Страница 13: ...8 White 3 9 T4 T5 T6 Together THREE PHASE 480 600 VOLT AC Power Cable Motor Lead Number Green Ground Green Black 1 Red 2 White 3 T4 T7 Together T5 T8 Together T6 T9 Together MOISTURE AND TEMPERATURE S...

Страница 14: ...e design con guration This number is used for ordering and obtaining information G 3 MODEL NUMBER This designation consists of numbers and letters which repre sent the discharge size series horsepower...

Страница 15: ...impeller for freedom of operation security and condition Clean impeller and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set...

Страница 16: ...16 FIGURE 10 4SEU Models ONLY 4SE 4SEU Pump Series...

Страница 17: ...17 FIGURE 11 4SE 4SEU Pump Series...

Страница 18: ...8 2 1 68 1 Cap Screw 1 2 13 x 1 1 4 lg Stainless 10 1 See Table 2 Conduit Box Cable Assembly 10a 1 Power Cable Not Sold Separately 10b 1 051447 Gland Nut 1 072559 Gland Nut For 7 5 11 3Hp 3Ph 15Hp 57...

Страница 19: ...1150RPM 8 75 Dia 084894TS 084895TS 8 62 Dia 084894TT 084895TT 15HP 1750RPM 8 50 Dia 084894TU 084895TU 8 38 Dia 084894TV 084895TV 8 25 Dia 084894TW 084895TW 8 12 Dia 084894TX 084895TX 11 3HP 1750RPM 8...

Страница 20: ...ring 53 5 016405 t Insulator 5 030149 t Insulator 7 5HP 1PH 15HP ONLY 54 1 052761 Wear Plate 4SEU s ONLY 55 4 1 130 1 Cap Screw 5 16 18 x 1 0 lg Stainless 56 4 20 2 1 Lockwasher 5 16 Stainless TABLE 2...

Страница 21: ...21 4SE HL High Ef ciency Pump Series FIGURE 12...

Страница 22: ...22 4SE HL High Ef ciency Pump Series FIGURE 13...

Страница 23: ...on Ring 2 071431A Friction Ring For 7 5 11 3Hp 3Ph 15Hp 575V 2 110929 Friction Ring For 7 5HP 1PH 15HP ONLY 10d 1 051452 Grommet 1 071430A Grommet For 7 5 11 3Hp 3Ph 15Hp 575V 1 110928 Grommet For 7 5...

Страница 24: ...ess 39 2 036803 Soc Hd Cap Screw 1 4 20 x 3 4 lg Stainless 41 1 036852 t Gasket 42 1 056668 t Square Ring 43 1 022879 Diaphragm Clamp Ring 44 4 002203 Cap Screw 1 4 20 x 7 8 lg Steel 46 1 039485 t Sha...

Страница 25: ...s between the results of eld testing conducted by or for user and laboratory tests corrected for eld performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FR...

Страница 26: ...nt To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by t...

Страница 27: ...O___ Type _________________________________ Number and size of short circuit device s ___________ Amp rating ___________________ Overload Type _____________ Size ______________ Amp rating ____________...

Страница 28: ...rols installed away from turbulence YES___ NO___ Is level control operating properly YES___ NO___ Is pump fully submerged during operation YES___ NO___ Follow up Corrective Action Required YES___ NO__...