background image

23

START-UP REPORT

FOR SUBMERSIBLE PUMPS

This form is designed to provide assurance that customer service and a quality product are the number one priority with 
Crane Pumps & Systems, Inc (CP&S). Please fi ll out the following questions as completely and accurate as possible. 
When complete, mail this form to:

 

In U.S.A Send To: 

In Canada Send To:

 

Crane Pumps & Systems, Inc 

Crane Pumps & Systems, Inc.

 

Attn: Warranty Service Group 

Attn: Service Manager

 

420 Third Street 

83 West Drive, Brampton

 

Piqua, Ohio 45356 

Ontario, Canada L6T 2J6

REPORTS THAT ARE NOT RETURNED CAN DELAY OR VOID WARRANTY.

Pump Owner’s Name:
Address:
Location of Installation
Person 

in 

Charge 

       Phone

Purchased From (Crane Pumps & Systems Representative/Distributor

Pump 

Model 

      

  Serial 

No.

Part Number
Voltage 

  Phase 

 

   

Hertz 

 

  Horespower

Rotation: Direction of impeller rotation (Use C/W for clockwise, CC/W for counter-clockwise)
Method used to check rotation (viewed from bottom)
Does impeller turn freely by hand:   

Yes 

 

No

Condition 

of 

equipment 

 Good 

 Fair 

  Poor

Condition of cable jacket   

Good 

 

Fair 

 

 

Poor

Resistance of cable jacket   

Good 

 

Fair 

 

 

Poor

Resistance of cable and pump motor (measured at pump control)
Red-Black 

 Ohms, 

Red-White 

  Ohms, 

White-Black 

 Ohms

Resistance of Ground Circuit between Control Panel and outside of pump 

 

 

Ohms

MEG Ohms check of insulation:
Red to Ground 

 

 

White to Ground    

 

 

Black to Ground

Condition of equipment at Start-Up: Dry 

 

 

Wet 

 

 

Muddy

Was Equipment Stored?   

 

 

 

Length of Storage

Describe station layout

Liquid being pumped
Debris in bottom of station?
Was debris removed in your presence?
Are guide rails exactly vertical?
Is BAF stationary installed level?

Liquid level controls:  Model
Are level controls installed away from turbulence?
Operation Check:
Tip lowest fl oat (Stop Float), All pumps should remain off.
Tip second fl oat (and Stop Float), one pump comes On.
Tip third fl oat (and Stop Float), both pumps on (alarm on simplex).
Tip fourth fl oat (and Stop Float), high level alarm on (omit on simplex).

If not CP&S level controls, describe type of controls
Does liquid level ever drop below volute top?

Содержание 4SCC Series

Страница 1: ...e product without prior written noti cation 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www c...

Страница 2: ...16 17 CROSS SECTION 180 Mtr FRame Fig 10 18 PARTS LIST 19 20 RETURNED GOODS POLICY 21 WARRANTY 22 START UP REPORT 23 24 WARRANTY REGISTRATION SPECIAL TOOLS AND EQUIPMENT INSULATION TESTER MEGGER DIELE...

Страница 3: ...insert ngers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety d...

Страница 4: ...Ball Grease Lubricated Load Radial LOWER BEARING Design Double Row Ball Grease Lubricated Load Radial Thrust MOTOR Design NEMA B Three Phase Torque Curve Air Filled Squirrel Cage Induction Insulation...

Страница 5: ...4SCE 4 2HP 25 23 641 17 27 439 6 77 172 7 95 202 16 00 404 4 80 122 4SCE 12 9 17 7HP 31 81 808 17 27 439 6 77 172 7 95 202 16 00 404 4 82 123 4SCF 4 2HP 25 90 658 18 49 470 7 13 181 1 7 95 202 16 00 4...

Страница 6: ...designed to pump unscreened raw sewage sludges slurries primary and secondary tank de slugging storm over ow wood pulp animal hide and eshings vegetable waste or other non explosive or non corrosive a...

Страница 7: ...rick moisture detection relay part number 1D1EO is an acceptable panel mounted relay See Figure 2 for typical wiring diagram In the event of a moisture detect the pump should be pulled and the source...

Страница 8: ...0 1750 H 14 4 80 0 14 4 SO 0 570 15 4SCD4844A 4 8 460 3 60 1750 H 7 2 40 0 14 4 SO 0 570 15 4SCD7134A 7 1 230 3 60 1750 H 19 4 114 0 8 4 SO 0 780 20 4SCD7144A 7 1 460 3 60 1750 H 9 7 57 0 8 4 SO 0 780...

Страница 9: ...aco Diala Oil AX Woco Premium 100 F 1 2 Testing Oil 1 Check oil for contamination using an oil tester with a range to 30 Kilovolts breakdown 2 If oil is found to be clean and uncontaminated measure ab...

Страница 10: ...bly F 3 1 Disassembly Loosen cable connectors 32 and 35 inspect connectors and replace if required Remove cable box cover 5 from motor housing 1 by removing cap screws 19 and washers 20 Remove cable l...

Страница 11: ...th at screw driver Upper Seal Remove lower seal as outlined above Remove screws 17 and washers 18 and remove intermediate 2 from motor housing 1 being careful not to damage o ring 21 or sensor probe 3...

Страница 12: ...acement is required remove bearing 12 from motor shaft using a wheel puller Remove snap ring 8 or screws 19 with washers 20 from bearing bracket 3 and remove bearing bracket 3 Now remove snap ring 15...

Страница 13: ...he design con guration This number is used for ordering and obtaining information G 3 MODEL NUMBER This designation consists of numbers and letters which rep resent the discharge size series horsepowe...

Страница 14: ...impeller for freedom of operation security and condition Clean impeller and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set...

Страница 15: ...15 FIGURE 9 Pump Series 4SCC 4SCD 4SCE 4SCF 100 132 Mtr Frame...

Страница 16: ...Box Cover 6 1 Rotor 7 1 Stator 8 1 Snap Ring 9 1 Upper Shaft Seal 10 1 Lower Shaft Seal 11 1 Lower Bearing 12 1 Upper Bearing 15 1 Snap Ring 16 1 Key 17 2 Screw 18 2 Washer 19 6 Screw 20 6 Washer 21 1...

Страница 17: ...34A 4844A 100 PA PB 7 68 195mm 7 48 190mm 7 09 180mm 095488 095488TA 095488TB STD 4SCE4236A 4246A 100 PA PB PC 9 06 230mm 8 66 220mm 8 27 210mm 7 87 200mm 095489 095489TA 095489TB STD 095489TC 4SCE129...

Страница 18: ...18 FIGURE 10 Pump Series 4SCF 180 Mtr Frame...

Страница 19: ...Washer 21 1 O Ring 23 1 Drain Plug 25 1 Snap Ring 26 1 Screw 27 1 Washer 29 25ft Power Cable 30 1 Ground 31 3 Wire Connector 32 2 Cable Connector 33 1 Wire Connector 34 25ft Control Cable 35 1 Cable...

Страница 20: ...ut 60 1 O ring 61 2 Nut TABLE 3 CUTTER IMPELLER Item No 41 PUMP MODEL MOTOR CASING ADDED SUFFIX TO BASIC PART NO IMPELLER DIA IMPELLER PART NO 4SCF29734A 29744A 180 PA PB PC 10 43 256mm 10 04 255mm 9...

Страница 21: ...o Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the e...

Страница 22: ...guarantees in the nature of performance speci cations furnished in addition to the foregoing material and workmanship warranties on a product manufactured by us if any are subject to laboratory tests...

Страница 23: ...m Does impeller turn freely by hand Yes No Condition of equipment Good Fair Poor Condition of cable jacket Good Fair Poor Resistance of cable jacket Good Fair Poor Resistance of cable and pump motor m...

Страница 24: ...ction Pump Off L1 L2 L2 L3 L3 L1 Voltage supply at panel line connection Pump On L1 L2 L2 L3 L3 L1 Amperage Load connection Pump On L1 L2 L3 FINAL CHECK Is pump seated on discharge properly Check for...

Страница 25: ...Notes...

Страница 26: ...Notes...

Страница 27: ...CITY STATE ZIP MODEL NO SERIAL NO PART NO BRAND IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty Complete the Warranty Registration Form and return to Crane Pumps Syst...

Страница 28: ...CRANE PUMPS SYSTEMS INC WARRANTY SERVICE GROUP 420 THIRD STREET PIQUA OHIO 45356 U S A FOLD HERE AND TAPE DO NOT STAPLE PLACE STAMP HERE...

Отзывы: