background image

Waste and emissions regulations

Observe these safety regulations regarding waste and emissions:

Ÿ

Dispose appropriately of all waste.

Ÿ

Handle and dispose of the processed liquid in compliance with applicable environmental regulations.

Ÿ

Clean up all spills in accordance with safety and environmental procedures.

Ÿ

Report all environmental emissions to the appropriate authorities.

Electrical installation

For electrical installation recycling requirements, consult your local electric utility.

Recycling guidelines

Always recycle according to the guidelines listed below:

Ÿ

Follow local laws and regulations regarding recycling if the unit or parts are accepted by an authorized recycling 
company.

Ÿ

If the first guideline is not applicable, then retum the unit or parts to the nearest BARMESA representative.

2. Prior to operation

Check the following points upon receipt of your pump.

Ÿ

Is it the pump you ordered?  Check nameplate. It is especially important that you check whether the pump is to be 
used with 50 or 60 Hz.

Ÿ

Has any damage occurred during shipment? Are any bolts or nuts loose?

Ÿ

Have all necessary accessories been supplied? For a list of standard accessories see drawing and parts list.

3. Installation

Check the following before beginning installation:

3.1 Insulation resistance measurement

With  the  motor  and  cable  (excluding  the  power  supply  cable)  immersed  in  water,  use  a  megger  to  measure  the 
insulation resistance between ground and each phase of the motor, and again between each phase of the motor.

The megger should indicate an insulation resistance of 

not less than 20 megaohms

. While making the measurement, 

keep the power supply cable off the ground.

NOTICE

 We recommend that an auxiliary pump be kept on hand in case of emergency.

barmesa.com

7

Содержание 2KLEIN-051

Страница 1: ...022 Installation Operation Maintenance Manual Submersible Stainless Steel Dewatering Pumps IMPORTANT Read all instructions in this manual before operating or servicing a pump KLEIN series 0 5 1 2 HP 3...

Страница 2: ...uild up heat and pressure during operation Allow time for pumps to cool DANGER before handling or servicing the pump or any accessory items associatedwithornearthepump Riskofelectric shock To reduce r...

Страница 3: ...dware CORDENTRY 32ftofneoprenecord sealedagainstmoisture BEARINGS Ball singlerow permanentlyoillubricated MOTOR Dry type submersible motor 1 3 phase 115 230 V 60 Hz 3450 RPM Insulation classBandIP68pr...

Страница 4: ...1 L W L DN D1 D HP A A1 D D1 DN H H1 H2 0 5 7 4 2 05 4 13 3 35 2 13 58 2 05 1 7 4 2 05 4 13 3 35 2 14 57 2 05 2 8 86 2 05 4 13 3 35 2 17 91 3 19 17 17 Weight without cord Dimensions in inches L W L lo...

Страница 5: ...t Productmalfunction Hazard levels NOTICE Savethismanualforfuturereference andkeepitreadilyavailableatthelocationoftheunit Hazard level Indication NOTICE DANGER WARNING CAUTION A hazardous situation w...

Страница 6: ...ions Thewarrantydoesnotcoverfaultscausedbythefollowing Deficientmaintenance Improperinstallation Modificationsorchangestotheproductandinstallationcarriedoutwithoutconsultingthemanufacturer Incorrectly...

Страница 7: ...propellersortheirretainingdevicestoaidintheirremoval DonotchangetheserviceapplicationwithouttheapprovalofanauthorizedBARMESArepresentative CAUTION You must observe the instructions contained in this...

Страница 8: ...restBARMESArepresentative 2 Prior to operation Checkthefollowingpointsuponreceiptofyourpump Is it the pump you ordered Check nameplate It is especially important that you check whether the pump is to...

Страница 9: ...lease valve wherever such air pockets are most likely to develop Do not permit end of discharge piping to be submerged as backflow will result when the pump is shut down Non automatic pumps do not hav...

Страница 10: ...d as the pump may jerk and cause serious accident involving injury 4 2 Cable 1 Ifthecableisextended donotimmersethespliceinwater 2 Do not pull the cable 3 Install the cable so that it will not overhea...

Страница 11: ...Single phase automatic L N PE Black Brown White Blue Green Yellow Green Ground PE Green Yellow Green Yellow Frame grounding Thermal protector Main Auxiliary Capacitor Float switch Figure 4 Three phas...

Страница 12: ...blockingtheinletsuction 6 2Regularinspections a Monthlyinspections Measure the insulation resistance The value should be more than 1 megaohm If resistance starts to fall rapidly even withaninitialindi...

Страница 13: ...ngorder referringtotheexplodedviewdrawings 1 Removepumpcasingbolts raisethemotorsectionandremovepumpcasing 2 Removeshaftheadboltandimpeller 3 Removeoilfillerpluganddrainlubricatingoil 4 Remove interme...

Страница 14: ...E MATERIAL 19 10 SCREW AISI 304 20 WASHER AISI 304 22 SCREW W O RING AISI 304 NBR 23 CABLE SEAT 26 T ADAPTER OPTIONAL 31 NUT AISI 304 31 2 NUT AISI 304 33 SPRING WASHER AISI 304 34 CORRUGATED SPRING S...

Страница 15: ...04 10 LIP SEAL NBR 11 IMPELLER AISI 304 ITEM NAME MATERIAL PHOTO 12 PUMP CASING AISI 304 13 PROTECTOR 1 PHASE KLIXON 13 PROTECTOR 3 PHASE KLIXON 14 CAPACITOR 15 1 15 2 BEARINGS 16 STRAINER AISI 304 17...

Страница 16: ...AISI 304 ITEM NAME MATERIAL 18 1 GASKET EPDM 18 2 GASKET EPDM 19 SCREW AISI 304 19 1 SCREW AISI 304 19 2 SCREW AISI 304 19 3 SCREW AISI 304 19 4 SCREW AISI 304 19 5 SCREW AISI 304 19 6 SCREW AISI 304...

Страница 17: ...SEAL NBR 11 IMPELLER AISI 304 ITEM NAME MATERIAL PHOTO 12 PUMP CASING AISI 304 13 PROTECTOR 1 PHASE KLIXON 13 PROTECTOR 3 PHASE KLIXON 14 CAPACITOR 15 1 15 2 BEARINGS 16 STRAINER AISI 304 17 1 17 2 O...

Страница 18: ...2 High liquid temperature has activated motor protector and caused pump to stop 3 Reverse rotation 1 Raise water level to C W L 2 Lower liquid temperature 3 Correct rotation Does not pump Inadequate...

Страница 19: ...barmesa com...

Отзывы: