background image

4

Receiving inspection

Upon  receiving  the  pump,  it  should 
be  inspected  for  damage  or 
shortages.  If  damage  has  occurred, 
file  a  claim  immediately  with  the 
company that delivered the pump. If 
the  manual  is  removed  from  the 
packaging, do not lose or misplace.

4

Storage

Any  product  that  is  stored  for  a 
period  longer  than  six  (6)  months 
from the date of purchase should be 
bench  tested  prior  to  installation.  A 
bench  test  consists  of,  checking  the 
impeller  to  assure  it  is  free  turning 
and  a  run  test  to  assure  the  motor 
(and  switch  if  provided)  operate 
properly.

4

Controls

Manual  models  require  a  separate 
approved  pump  control  device  or 
panel  for  automatic  operation.  Be 
sure the electrical specification of the 
control  selected  properly  match  the 
electrical specifications of the pump.

4

Submergence

The  pump  should  always  be 
operated 

in 

the 

submerged 

condition. The minimum sump liquid 
level should never be less than above 
the pump’s volute (See Figure 1).

3

Recommendations and Warnings

4

Liquid Level Control

Typical Discharge Pipe Mounted:

Refer to Figure 2 below which shows 
a typical installation of a 1 phase 115 
volt  pump  using  a  level  control 
mounted  to  the  discharge  piping 
with  a  piggyback  plug.  The  level 
control  should  have  adequate 
clearance so it cannot hang up in it’s 
swing  and  that  the  pump  is 
completely  submerged  when  the 
level  control  is  in  the  "Off"  mode.  By 
adjusting the cord tether the control 
level can be changed.

Typical Discharge Pipe Mounted

Level Control

Level Control Basic instructions:

Plug  the  level  control  plug  into  the 
GFI  receptacle,  then  plug  the  pump 
into  the  piggy-back  plug  (See  Figure 
3).  One  cycle  of  operation  should  be 
observed,  so  that  any  potential 
problems can be corrected.

It  is  recommended  that  the  level 
control  float  should  be  set  to  insure 
that  the  liquid  in  the  sump  never 
drops  below  the  top  of  the  motor 
housing  or  a  minimum  level  of  6 
inches above the basin floor.

Figure 1

Recommended
Submergence Level

Minimum
Submergence Level

6"

Bottom of Feet

DISCHARGE

VENT

INLET

GATE

VALVE

UNION

CHECK VALVE

Drill 

" dia. vent hole

to prevent air locking

4

Installation

These  pumps  are  recommended  for 
use  in  a  sump  or  basin. The  sump  or 
basin  shall  be  sealed  and  vented  in 
accordance  with  local  plumbing 
codes. 

This  pump  is  designed  to 

pump  effluent  or  wastewater, 
nonexplosive  and  noncorrosive 
liquids  and  shall  NOT  be  installed 
in locations classified as hazardous 
in  accordance  with  the  National 
Electrical  Code  (NEC)  ANSI/NFPA 
70 or Canadian Electric Code (CEC)

The  pump  should  never  be  installed 
in  a  trench,  ditch,  or  hole  with  a  dirt 
bottom.  The  legs  will  sink  into  the 
dirt  and  the  suction  will  become 
plugged.

The  installation  should  be  at  a 
sufficient  depth  to  ensure  that  all 
plumbing  is  below  the  frost  line.  If 
this is not feasible, remove the check 
valve  and  size  the  basin  to 
accommodate 

the 

additional 

backflow volume.

4

Discharge Piping

Discharge  piping  should  be  as  short 
as possible and sized no smaller than 
the  pump  discharge. 

Do  not  reduce 

the  discharge  pipe  size  below  that 
which is provided on the pump.

Figure 3

barmesa.com

Содержание 2BSE411 Series

Страница 1: ...tion Maintenance Manual Submersible Solids Handling Pumps IMPORTANT Read all instructions in this manual before operating or servicing a pump 2BSE411 2BSE511 SERIES 0 4 0 5 HP 1750 RPM Last update 12 03 2020 barmesa com ...

Страница 2: ...efore handling or servicing the pump or any accessory items associatedwithornearthepump T h i s p u m p i s n o t i n t e n d e d f o r u s e i n swimming pools or water installations where there is DANGER humancontactwithpumpedfluid Riskofelectric shock To reduce risk of electric shock always disconnect pump from power source before DANGER handling any aspect of the pumping system Lockoutpowerand...

Страница 3: ...sed SEAL Single mechanical oil filled chamber Silicon carbide Buna N elastomer and stainlesssteelhardware CORDENTRY 20ftofneoprenecord sealedagainstmoisture UPPERBEARING Ball singlerow oillubricated forradialload LOWERBEARING Ball singlerow oillubricated forradialandthrustload MOTOR NEMA L singlephase permanentsplitcapacitor oilfilled withoverload protection inmotor MODEL PART No HP VOLTS PHASE RP...

Страница 4: ...l Discharge Pipe Mounted Level Control Level Control Basic instructions Plug the level control plug into the GFI receptacle then plug the pump into the piggy back plug See Figure 3 One cycle of operation should be observed so that any potential problems can be corrected It is recommended that the level control float should be set to insure that the liquid in the sump never drops below the top of t...

Страница 5: ...n damage the motor and or pump Incorrect rotation for Single Phase pumps is unlikely If the rotation is incorrect contact factory 3 Name Plate Record the information from the pump name plate to drawing in front of manual for future reference 4 Insulation Test An insulation megger test should be performed on the motor Before the pump is put into service The resistance values ohms as well as the vol...

Страница 6: ...age and replace if required To remove impeller place a flat screwdriver in the slot of the end of the shaft to hold the shaft stationary while unscrewing the impeller 5 Check v ring and remove if damaged Power Cord and Motor 6 Remove pipe plug and drain oil from housing 7 Remove gland nut washer and ring from housing Pull cord through and disconnect the wires from the terminals on power cord 8 Rem...

Страница 7: ...apped surface of rotating member facing outward slide over shaft using a seal tool being carefull not to damage seal face Make sure spring is seated in retaining ring and spring is lined up on rotating member and not cocked or resting on bellows tail Motor 5 Slide rotor shaft with bearings and seal parts into seal plate until bearing seats into seal plate Install snap ring into seal plate 6 Place ...

Страница 8: ...7 Repair Parts For Repair Part Please supply Model Number and Serial as shown on Name Plate and Part Description and Part Number as shown on Parts List barmesa com ...

Страница 9: ...ER Ø138 2 1 HT200 16 CASING 1 HT200 17 CASING SEALING WASHER 1 RUBBER 18 HEX SOCKET CAP SCREW 1 4 20UNC x 28 2 SS 304 19 V SHAPE RING 1 NBR40 20 MECHANICAL SEAL 1 2 Ø25 4 1 SiC SiC 21 ELASTIC COLLAR 40 1 65Mn 22 BEARING 6203 1 23 LENGTHERN BOLT 8 32 x 125 4 Q235A 24 FLATWASHER 4 4 Q235A 25 SPRING WASHER 4 4 65Mn 26 LOWER BEARING PLATE O RING 1 NBR40 27 CAPACITOR CLAMP 1 08F 28 CROSS RECESS PAN HEA...

Страница 10: ...wer supply leads to ensure proper impeller rotation 11 Repair fixturesasrequiredtoeliminateleakage 12 Check pump temperature limits and fluid temperature 13 Replace portion of discharge pipe with flexible connector or tighten existing piping 14 Turn to automatic position 15 Check for leaks around basin inlet and outlets Pump will not turn off 2a Float movement restricted 2b Switch will not activat...

Страница 11: ......

Отзывы: