background image

6

Service

11.  Inspect  motor  winding  for  shorts 
and  check  resistance  values.  Check 
rotor  for  wear.  If  rotor  or  the  stator 
windings are defective, the complete 
motor must be replaced.

Shaft Seal:

12. Remove snap ring from seal plate. 
Remove  shaft  and  motor  rotor  from 
seal plate.

13.  Remove  seal’s  rotating  member, 
spring  and  retaining  ring  from  seal 
plate.  Examine  all  seal  parts,  if  seal 
faces  show  signs  of  wear,  uneven 
wear  pattern,  chips  or  scratches 
replace 

entire 

seal. 

DO 

NOT 

interchange 

seal 

components, 

replace  the  entire  shaft  seal

.  If 

replacing  seal,  remove  stationary 
from seal plate by prying out with flat 
screwdriver.

Bearings:

14.  Examine  lower  bearing,  and 
upper  bearing,  if  replacement  is 
required,  remove  by  using  a  wheel 
puller.

IMPORTANT!  -  All  parts 
must 

be 

clean 

before 

reassembly.  Handle  seal

parts  with  extreme  care.  DO  NOT 
damage lapped surfaces.

4

Reassembly

Bearings:

1. Press bearings and onto shaft.

Shaft Seal:

2.  Clean  seal  cavity  in  seal  plate  and 
oil.  Press  seal’s  stationary  member 
firmly  into  seal  plate,  use  a  seal  tool 
or  pipe.  Nothing  should  come  in 
contact with the seal face except the 
seal  tool.  Be  sure  the  stationary  is  in 
straight.

3.  Place  seal’s  retaining  ring,  spring 
onto  shaft.  Lightly  oil 

(Do  not  use 

grease)

  shaft  and  inner  surface  of 

bellows.

4.  With  lapped  surface  of  rotating 
member  facing  outward,  slide  over 
shaft using a seal tool, being carefull 
not  to  damage  seal  face.  Make  sure 
spring is seated in retaining ring and 
spring  is  lined  up  on  rotating 
member  and  not  cocked  or  resting 
on bellows tail.

Motor:

5. Slide rotor/shaft with bearings and 
seal parts into seal plate until bearing 
seats into seal plate. Install snap ring 
into seal plate.

6.  Place  spring  washer  onto  bearing 
and  lower  housing  and  stringing 
motor  leads  through  the  cord  entry 
bore,  with  motor  stator  onto  seal 
plate.

7.  Place  screws  through  seal  plate 
into housing and torque to 60 in/lbs.

Power Cord:

8.  Check  power  cord  for  cracks  or 
damage  and  replace  if  required. 
Reconnect  motor  leads  to  the 
underside of the terminal holder.

9.  Place  power  cord  with  nylon 
housing,  ring,  washer  and  gland  nut 
into  housing  and  tighten  gland  nut 
to 17.5 ft/lbs.

Impeller, V-ring and Volute:

10. Position v-ring into seal plate until 
seated.

11.  Clean  the  threads  with  thread 
locking  compound  cleaner.  Apply 
removable Loctite® 242 or equivalent 
to shaft threads. Screw impeller onto 
the  shaft  hand  tight  while  using  a 
screwdriver  in  the  slot  at  the  end  of 
the shaft to hold it stationary. Rotate 
impeller to check for binding. 

12.  Position  gasket  on  volute  flange 
and  position  impeller  and  motor 
housing assembly on volute.

13. Place lock washers on cap screws 
and  screw  into  volute.  Torque  to  11 
ft/lbs.  Check  for  free  rotation  of 
impeller.

14. Refill with cooling oil.

barmesa.com

Содержание 2BSE411 Series

Страница 1: ...tion Maintenance Manual Submersible Solids Handling Pumps IMPORTANT Read all instructions in this manual before operating or servicing a pump 2BSE411 2BSE511 SERIES 0 4 0 5 HP 1750 RPM Last update 12 03 2020 barmesa com ...

Страница 2: ...efore handling or servicing the pump or any accessory items associatedwithornearthepump T h i s p u m p i s n o t i n t e n d e d f o r u s e i n swimming pools or water installations where there is DANGER humancontactwithpumpedfluid Riskofelectric shock To reduce risk of electric shock always disconnect pump from power source before DANGER handling any aspect of the pumping system Lockoutpowerand...

Страница 3: ...sed SEAL Single mechanical oil filled chamber Silicon carbide Buna N elastomer and stainlesssteelhardware CORDENTRY 20ftofneoprenecord sealedagainstmoisture UPPERBEARING Ball singlerow oillubricated forradialload LOWERBEARING Ball singlerow oillubricated forradialandthrustload MOTOR NEMA L singlephase permanentsplitcapacitor oilfilled withoverload protection inmotor MODEL PART No HP VOLTS PHASE RP...

Страница 4: ...l Discharge Pipe Mounted Level Control Level Control Basic instructions Plug the level control plug into the GFI receptacle then plug the pump into the piggy back plug See Figure 3 One cycle of operation should be observed so that any potential problems can be corrected It is recommended that the level control float should be set to insure that the liquid in the sump never drops below the top of t...

Страница 5: ...n damage the motor and or pump Incorrect rotation for Single Phase pumps is unlikely If the rotation is incorrect contact factory 3 Name Plate Record the information from the pump name plate to drawing in front of manual for future reference 4 Insulation Test An insulation megger test should be performed on the motor Before the pump is put into service The resistance values ohms as well as the vol...

Страница 6: ...age and replace if required To remove impeller place a flat screwdriver in the slot of the end of the shaft to hold the shaft stationary while unscrewing the impeller 5 Check v ring and remove if damaged Power Cord and Motor 6 Remove pipe plug and drain oil from housing 7 Remove gland nut washer and ring from housing Pull cord through and disconnect the wires from the terminals on power cord 8 Rem...

Страница 7: ...apped surface of rotating member facing outward slide over shaft using a seal tool being carefull not to damage seal face Make sure spring is seated in retaining ring and spring is lined up on rotating member and not cocked or resting on bellows tail Motor 5 Slide rotor shaft with bearings and seal parts into seal plate until bearing seats into seal plate Install snap ring into seal plate 6 Place ...

Страница 8: ...7 Repair Parts For Repair Part Please supply Model Number and Serial as shown on Name Plate and Part Description and Part Number as shown on Parts List barmesa com ...

Страница 9: ...ER Ø138 2 1 HT200 16 CASING 1 HT200 17 CASING SEALING WASHER 1 RUBBER 18 HEX SOCKET CAP SCREW 1 4 20UNC x 28 2 SS 304 19 V SHAPE RING 1 NBR40 20 MECHANICAL SEAL 1 2 Ø25 4 1 SiC SiC 21 ELASTIC COLLAR 40 1 65Mn 22 BEARING 6203 1 23 LENGTHERN BOLT 8 32 x 125 4 Q235A 24 FLATWASHER 4 4 Q235A 25 SPRING WASHER 4 4 65Mn 26 LOWER BEARING PLATE O RING 1 NBR40 27 CAPACITOR CLAMP 1 08F 28 CROSS RECESS PAN HEA...

Страница 10: ...wer supply leads to ensure proper impeller rotation 11 Repair fixturesasrequiredtoeliminateleakage 12 Check pump temperature limits and fluid temperature 13 Replace portion of discharge pipe with flexible connector or tighten existing piping 14 Turn to automatic position 15 Check for leaks around basin inlet and outlets Pump will not turn off 2a Float movement restricted 2b Switch will not activat...

Страница 11: ......

Отзывы: