background image

Shaft Seal:

14. Lift motor rotor, shaft, bearing (6), 
rotating  member  of  seal,  washer  (7) 

from seal plate (15). See Figure 3.

15.  Remove  seal  parts  from  shaft. 

Examine  all  seal  parts,  if  seal  faces 

show  signs  of  wear,  uneven  wear 
pattern,  chips  or  scratches  replace 
entire  seal. 

DO  NOT  interchange 

seal  components,  replace  the 

entire  shaft  seal  (24)

.  If  replacing 

seal,  remove  stationary  from  seal 

plate  (15)  by  prying  out  with  flat 

screwdriver.

2.  Press  seal’s  stationary  member 

firmly  into  seal  plate  (15),  use  a  seal 
tool or pipe. Nothing should come in 

contact with the seal face except the 

seal  tool.  Be  sure  the  stationary  is  in 
straight.

3. Press lower bearing (6) onto shaft.

4. Place seal’s (24) retaining ring and 
spring onto shaft. Lightly oil 

(Do not 

use  grease)

  shaft  and  inner  surface 

of bellows.

5.  With  lapped  surface  of  rotating 
member  facing  outward,  slide  over 

shaft using a seal tool, being carefull 
not  to  damage  seal  face.  Make  sure 
spring is seated in retaining ring and 
spring  is  lined  up  on  rotating 

member  and  not  cocked  or  resting 
on bellows tail.

7. Lubricate and place square ring (14) 
into bore on seal plate (15).

Impeller and Volute:

10.  Install  v-gasket  (23)  and  impeller 

washer  (17)  over  shaft,  and  into  seal 

plate (15).

11.  Install  impeller  (16)  by  cleaning 
the  threads  with  thread  locking 

compound  cleaner.  Apply  removable 

Loctite®  609  or  equivalent  to  shaft 
threads.  Screw  impeller  onto  shaft 

hand  tight  while  using  a  screwdriver 
in  the  slot  at  the  end  of  the  shaft  to 
hold  it  stationary.  Rotate  impeller  to 

check for binding.

12. Place gasket (19) onto volute (18).

Cable Assembly:

14. Check power cord (1) for cracks or 

damage and replace if required. Insert 
one  friction  ring,  grommet,  one 

friction ring, and gland nut into motor 
housing  (3)  or  conduit  box  and  cable 

assembly  (1)  and  torque  wire  nut  to 
15 ft. lbs.

06

Service

Shaft Seal:

1. To reassemble, clean seal cavity in 
seal plate (15) and oil. 

IMPORTANT!  -  All  parts 

must  be  clean  before 

reassembly.  Handle  seal

parts  with  extreme  care.  DO  NOT 

damage lapped surfaces.

Reassembly

Bearing and Motor:

6.  Slide  rotor/shaft  with  bearing  (6) 

and seal parts (24) into seal plate (15) 

until  bearing  seats  into  seal  plate. 
Place  stator  over  rotor,  lining  up 

motor  bolts  with  holes  in  seal  plate 

(15). Insert motor bolts and torque to 

17 inch pounds.

8.  On  Single  phase  units,  connect 
capacitor  (4)  to  motor  wires.  See 

Figure  5.  Install  ground  wire  on  end 
bell if removed. Place fiberglass sleeve 

over  motor  and  ground  leads  if 

removed.  Pull  wires  through  opening 
in  top  of  motor  housing  while 
lowering  motor  housing  onto  seal 
plate (15).

9.  Place  socket  head  screws  (31) 

through seal plate into motor housing 
and torque to 60 inch pounds.

13.  Lower  motor  housing  and  seal 

plate assembly onto volute (18). Apply 
thread 

locking 

compound 

to 

capscrews  and  with  washers  place 
through  motor  housing,  into  volute 

and torque to 11 ft. lbs.

15

6

23

barmesapumps.com

Содержание 2BSE102SS

Страница 1: ...rsible Solids Handling Pumps IMPORTANT Read all instructions in this manual before operating or servicing a pump 2BSE SS 0 5 0 75 1 HP 1750 RPM 2BSE51SS 0 5 HP 2BSE72SS 2BSE73SS 2BSE74SS 0 75 HP 2BSE1...

Страница 2: ...associatedwithornearthepump T h i s p u m p i s n o t i n t e n d e d f o r u s e i n swimming pools or water installations where there is DANGER humancontactwithpumpedfluid Riskofelectric shock To re...

Страница 3: ...ctioninmotor Three phase NEMA B oil filled Requires overload protection to be included in controlpanel 18 661 6 687 2 165 2 FLANGE 9 763 12 637 6 5 4 875 12 937 11 8 3 FLANGE MODEL PART No HP VOLTS PH...

Страница 4: ...top of the motor housing or a minimum level of 10 inches above the basin floor Electrical Connections Power cable The power cable mounted to the pump must not be modified in any way except for shorten...

Страница 5: ...ll with new oil Insulation Test An insulation megger test should be performed on the motor Before the pump is put into service The resistance values ohms as well as the voltage volts and current amps...

Страница 6: ...ocks or 4 piece of pvc pipe to avoid resting unit on shaft 05 Service Pressure builds up extremely fast increase pressure by TAPPING air nozzle Too much pressure will damage seal DO NOT exceed 10 PSI...

Страница 7: ...r equivalent to shaft threads Screw impeller onto shaft hand tight while using a screwdriver in the slot at the end of the shaft to hold it stationary Rotate impeller to check for binding 12 Place gas...

Страница 8: ...POWER CORD 4x12 G T1 T7 T2 T8 T3 T9 T4 T5 T6 G L1 L2 L3 GREEN BLACK RED WHITE MOTOR LEADS Cable Motor Lead Number Green Green Black 1 and 7 Red 2 and 8 White 3 and 9 4 5 and 6 together Figure 4 T2 T3...

Страница 9: ...08 Repair Parts Figure 5 For Repair Part Please supply Model Number and Serial as shown on Name Plate and Part Description and Part Number as shown on Parts List barmesapumps com...

Страница 10: ...R 3 DISHARGE 1 HT200 22 HEX SOCKET CAP SCREWS 1 4 20UNC x 28 2 SS 304 23 V SHAPE RING 1 NBR 40 24 MECHANICAL SEAL 31 8 x 15 9 x 32 5 1 SiC SiC 25 ELLASTIC COLLAR 40 1 65Mn 26 ELLASTIC COLLAR 17 1 65Mn...

Страница 11: ...supply leads to ensure proper impeller rotation 11 Repair fixturesasrequiredtoeliminateleakage 12 Check pump temperature limits and fluid temperature 13 Replace portion of discharge pipe with flexible...

Страница 12: ......

Отзывы: