page 20
595 ML CRL (S)
800-00177
SERVICE SCHEDULE CONTINUED...
8 hours
Daily
SERVICE REQUIRED
50 hours
Weekly
100 hours
Monthly
400 hours
2 Months
1000 hrs
6 Months
Yearly
Battery - Clean and coat posts with grease. Check
electrolyte level and fill if necessary.
Engine Oil Filter - Replace.
Follow engine manufacturers guidelines.
Hydraulic Oil Cooler and Radiator - Clean.
Hydraulic Oil Reservoir Breather - Replace.
Accumulators - Check pressure and maintain at 1200
PSI.
Hydraulic Collector - Check mounting bolts.
Pump Drive - Replace fluid.
Hydraulic Oil Filters - Replace elements every 400
hours, after initial change at 100 hours on a new
machine.
Hydraulic Oil Reservoir - Change fluid.
Entire Loader - Steam clean, inspect for stress, wear,
cracks, damage, and loose parts.
Pilot Filters in Valve Banks - Remove, inspect and
clean.
Swing Motor Gearboxes - Change fluid.
NOTE: Use the intervals on Service Schedule when operating in normal conditions. Service the machine at shorter
intervals when operating in very hot, cold, dusty, or humid conditions.
Air Conditioner Air Intake Filter - Replace.
Hydraulic Oil Filter - On new machines the filter
element should be replaced first at 100hrs. and
then at 400 hrs. thereafter.
Содержание 595ML
Страница 3: ...page3 595 ML CRL S 800 00177 Introduction Marker...
Страница 16: ...page16 595 ML CRL S 800 00177 Maintenance A PREVENTIVE MAINTENANCE Maintenance...
Страница 27: ...page27 595 ML CRL S 800 00177 Maintenance B HYDRAULIC SYSTEM...
Страница 33: ...page33 595 ML CRL S 800 00177 HYDRAULIC PRESSURE ADJUSTMENT CONTINUED 558 01699...
Страница 44: ...page44 595 ML CRL S 800 00177 Maintenance C ELECTRICAL SYSTEM MAINTENANCE...
Страница 67: ...page67 595 ML CRL S 800 00177 Maintenance D POWER UNIT MAINTENANCE...
Страница 77: ...page77 595 ML CRL S 800 00177 Structural E STRUCTURAL MAINTENANCE...
Страница 84: ...page84 595 ML CRL S 800 00177 Trouble Shooting Marker Marker Marker...