Service work
34
Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Head Office: +49 (5202) 9801-0
Customer Service: +49 (5202) 9801-30 Fax: +49 (5202) 9801-99 - e-mail: [email protected]
Service manual
Barkey warming center III DTM
7.9
Replacing the microswitch
Removal:
►
Remove the heater insert (see Chapter 7.2).
►
Remove the cover plate (see Chapter 7.2).
►
Undo the nuts from the microswitch using a 14mm jaw spanner, and pull it off the
front panel to the rear.
►
Pull the spade connectors off the microswitch.
Refitting the microswitch:
Refitting the microswitch takes place in reverse order to removal:
►
Press the microswitch into the cutout in the front panel, and tighten the nuts using a
14 mm jaw spanner.
NOTE
The microswitch must be flush with the front panel from behind so that it switches
correctly when the door is closed.
►
Push the spade connectors onto the
microswitch:
– one cable to the middle contact
– the other cable to the rear contact
The polarity is not important.
Figure 35: Microswitch collections
►
Refix the cover plate (see Chapter 7.2).
►
Refit the heater insert (see Chapter 7.2).