CASE CLEANING

CASE CLEANING

A periodic cleaning schedule should be established to maintain 
proper  sanitation,  insure  maximum  operating  efficiency,    and  
avoid the corrosive action of food fluids on metal parts that are 
left on for long periods of time.  We recommend cleaning once 
a week.  Further suggestions for case cleaning include the fol-
lowing:

• 

To avoid shock hazard, be sure all electrical power is turned 
off before cleaning.  In some installations, more than one 
disconnect switch may have to be turned off to completely 
de-energize the case.

• 

All surfaces pitch downward to a deep-drawn drain trough, 
funneling liquids to the center of the case where the waste 
outlet is located for easy access.  Check the waste outlet to 
insure it is not clogged before starting the cleaning process 
and avoid introducing water faster than the case drain can 
carry it away. 

• 

To clean the LED luminaires, shut off the lights in the case, 
then  wipe  the  luminaires  down  with  a  soft,  damp  cloth.  
Avoid using harsh or abrasive cleaners as they may dam-
age the lights.  Be certain that the luminaires are complete-
ly dry before re-energizing.

• 

Clean from top to bottom when cleaning the display case to 
avoid cross contamination.

• 

If  any  potentially  harmful  cleaners  are  used,  be  certain 
to  provide  a  temporary  separator  (e.g.,  cardboard,  plastic 
wrap,  etc.)  between  those  cases  that  are  being  cleaned 
and those that may still contain product.

• 

Avoid spraying any cleaning liquids directly on the electrical 
connections.

• 

Allow cases to be turned off long enough to clean any frost 
or ice from coil and pans.

• 

Remove  toekick  and  clean  underneath  the  case  with  a 
broom  and  a  long-handled  mop.    Use  warm  water  and  a 
disinfecting  cleaning  solution  when  cleaning  underneath 
the cases. 

     

D A N G E R

 

SHOCK HAZARD

Always disconnect power to case when servicing 
or cleaning.  Failure to do so may result in serious 
injury or death.

     

W A R N I N G

 

Exercise extreme caution when working in a case 
with  the  coil  cover  removed.    The  coil  contains 
many sharp edges that can result in severe cuts 
to the hands and arms.

14

Содержание AGB

Страница 1: ...ase Cleaning 14 15 Parts Ordering 16 Appendices Table of Contents To ensure proper functionality and optimum performance it is STRONGLY recommended that Hillphoenix specialty cases be installed servic...

Страница 2: ...ii...

Страница 3: ...ith shelf lighting systems for direct or indirect exposure to water or other liquids The use of a misting system or water hose on a display case with a shelf lighting system resulting in the direct or...

Страница 4: ...installation and operations handbooks accompanied by an alert symbol paired with the word DANGER WARNING or CAUTION All warning messages will inform you of the potential hazard how to reduce the risk...

Страница 5: ...parts list_09 12 energy data and parts list_01 13 endviews_03 13 text update and air ow diagram_06 13 energy data_07 13 energy data_02 14 endviews and energy data_09 14 support diagram and parts page...

Страница 6: ...Watts Amps Watts Amps Watts Amps Watts AGB 4 6 8 Model Lights per Row Light Length ft Fluorescent Lighting Per Light Row Clearvoyant LED Lighting Per Light Row Standard Power Cornice or Shelf High Pow...

Страница 7: ...ghted shelves Add the following for lighted shelves 4 Fluorescent 80 BTUH 3 Fluorescent 60 BTUH 4 Shelf LED 36 BTUH 4 Canopy LED 72 BTUH 3 Shelf LED 27 BTUH 3 Hi Output LED 54 BTUH 6 EPR valve is fact...

Страница 8: ...cm 21 13 16 in 55 4 cm 49 13 16 in 126 5 cm 93 1 2 in 237 5 cm 93 1 2 in 237 5 cm 49 1 4 in 125 1 cm 49 1 4 in 125 1 cm REFLECTIVE REAR LOAD DOORS REFLECTIVE REAR LOAD DOORS 30 PROFILE 36 PROFILE 48...

Страница 9: ...e it is delivered to the consumer Our liability ceases at the time of shipment RECEIVING CASES Examine fixtures carefully and in the event of shipping dam age and or shortages please contact the Servi...

Страница 10: ...cross support and lower the horizontal support on to the shim packs Repeat on the other end of the case LOCATION This refrigerated display case has been designed for displaying and storing perishable...

Страница 11: ...umper for nal t and n ish Be certain to use an appropriate cutting tool tubing or PVC cutter to ensure a smooth cut 7 Install case shelves and reconnect lights Be aware that differing shelf con gurati...

Страница 12: ...ns are compliant with local codes C A U T I O N Be sure to remove all styrafoam shipping blocks from piping and refrigerant lines Failure to do so may result in case damage Fig 4 P trap drain outlet P...

Страница 13: ...43 8 cm 8 case 18 in 45 7 cm 14 in 35 6 cm 28 in 71 1 cm 30 34 in 86 4 cm 36 30 in 76 2 cm 36 in 91 4 cm 26 in 66 0 cm 30 32 in 81 3 cm 36 TOEKICK 15 x 15 MECHANICAL ACCESS FOR ELECT REFRIG AND DRAIN...

Страница 14: ...G E R SHOCK HAZARD Always disconnect power to case when cleaning servicing or con guring components of the light ing system Failure to do so may result in serious injury or death REPLACING T 8 LIGHTS...

Страница 15: ...remove Re installing shelf luminaires 1 Place hook into shelf roll form at shelf front and rotate rear of luminaire toward the shelf 2 Depress the rear clip so that luminaire can nish rotation and un...

Страница 16: ...ines see pg 8 After powering up the case be certain that all of the steps listed below have been completed to ensure proper case functionality safety and compliance with warranty terms 1 Check all lig...

Страница 17: ...a case 1 Store Conditions Hillphoenix cases are designed to oper ate in an air conditioned store that maintains a 75 F 24 C store temperature and 55 max relative humidity ASHRAE conditions Case opera...

Страница 18: ...he luminaires down with a soft damp cloth Avoid using harsh or abrasive cleaners as they may dam age the lights Be certain that the luminaires are complete ly dry before re energizing Clean from top t...

Страница 19: ...product only extra strength or specialty products may not be suitable Glass Plus standard product only extra strength or specialty products may not be suitable Exceed Multi Surface Glass Cleaner from...

Страница 20: ...case for which the part is intended Length of the part if applicable Color of part if painted or color of polymer part Whether part is for left or right hand application Quantity Data tag is located o...

Страница 21: ...A1 A2 Wiring Information B1 B4 Dixell Operating Instructions C1 Sporlan Pressure Temperature Chart D1 Parts List APPENDIX 17...

Страница 22: ...A1 WIRING DIAGRAM...

Страница 23: ...UE LIGHT BLACK LIGHT SWITCH WHITE FROM 2 2 BLACK BALLAST WHITE BALLAST BLACK LIGHT RED LIGHT BLACK FROM BLOCK 1 1 BLACK TO DIXELL 5 41 WHITE TO DIXELL 6 42 WHITE SOL JUNCTION BOX 26 27 78 BLACK TO CHI...

Страница 24: ...int 3 1 DEFROST Defrost is performed through a simple stop of the compressor Parameter IdF controls the interval between defrost cycles while its length is controlled by parameter MdF To disable the d...

Страница 25: ...ow and above the humidity set point SET_RH The dehumidifying action is enabled when the humidity increases and reaches the SET_RH dbH value It is stopped when it comes back to the SET_RH The humidifyi...

Страница 26: ...ring this time and then for the delay dot and doH after closing the door the temperature and humidity alarms are disabled 7 2 GENERIC ALARM I1F EAL As soon as the digital input is activated the unit w...

Страница 27: ...ative humidity 20y85 no condensing Measuring and regulation range NTC probe 40 110 C 58 230 F Resolution 0 1 C or 1 C or 1 F selectable Accuracy ambient temp 25 C 0 5 C 1 digit 13 WIRING CONNECTIONS 1...

Страница 28: ...29 4 381 8 17 8 3 16 4 51 5 54 3 30 4 388 0 18 7 8 17 0 52 7 55 6 31 4 394 3 19 7 2 17 7 54 0 56 9 32 4 400 7 20 6 7 18 4 55 3 58 3 33 5 407 2 21 6 1 19 1 56 6 59 6 34 6 413 8 22 5 6 19 9 58 0 61 0 3...

Страница 29: ...S Wire Riser F Front Toekick G Outside Front H End Toekick I Dry or Refrigerated Lower Storage J End Panel K Fixed End Glass L Shelf Standard M Outside Back N Rear Load Doors O Light Guard P Upper Int...

Страница 30: ...rned within two weeks after startup 5 If the defective part is not returned to the Manufacturer 6 To service maintenance or wear and tear parts such as lights starters and ballasts MODIFICATIONS TO GE...

Страница 31: ...er directly on fan motors or any electrical connections All lighting receptacles must be dried off prior to insertion and re energizing the lighting circuit Please refer to the Use and Maintenance sec...