T3-OPPAD

 TFT Remote Keypad IP55 User Guide   |   

Version 1.02

www.

bardac

.com

Switching Frequency 

Reduction

Mains Loss

Maintenance 

 Time Elapsed

Name

01 Name

01 Name

01 Name

01

SF

23.7Hz

ML

23.7Hz

OL

23.7Hz

23.7Hz

15.3A

15.3A

6.9kW

15.3A

6.9kW

15.3A

6.9kW

Switching frequency is 
reduced, due to high 
heatsink temperature.

The incoming mains 
power supply has been 
disconnected or is missing.

The motor is in overload 
drawing a current higher 
than its rated current.

The user programmable 
maintenance reminder time 
has elapsed.

Changing Parameters

Name

01 Name

01 Name

01 Name

01 Name

01

Stop

P1-01

P1-08

30.0A 



P1-08

Stop

15kW 400V 3Ph 50.0Hz

30.0A

P1-08

30.0

3.0 30.0A

15kW 400V 3Ph

Press and hold the 
Navigate key > 2 
seconds.

Use the Up and 
Down keys to 
select the required 
parameter.
Display will 
show the present 
parameter value on 
the lower line of the 
display.

Press the Navigate 
key for < 1 second.

Adjust the value 
using the Up 
and Down keys. 
Display will show 
the maximum and 
minimum possible 
settings on the 
lower line of the 
display.

Press for < 1 second 
to return to the 
parameter menu.

Press for > 2 
seconds to return 
to the operating 
display.

Parameter Factory Reset / User Reset

Factory Parameter Reset :

User Parameter Reset :

Name

01 Name

01 Name

01 Name

01 Name

01 Name

01

Stop

P-Def

Stop

Stop

U-Def

Stop

15kW 400V 3Ph 50.0Hz

15kW 400V 3Ph P1-08

30.0

3.0 30.0A

15kW 400V 3Ph

Press and hold the 
Up, Down, Start 
and Stop keys for 
>2s.

The display shows 
P-def. Briefly press
the Stop key.

The display 
returns to Stop. All 
parameters are 
reset to Factory 
defaults.

Press and hold the 
Up, Down and Stop 
keys for >2s.

The display shows 
U-def. Briefly press
the Stop key.

The display 
returns to Stop. 
All parameters 
are reset to User 
Defaults.

Содержание T3-OPPAD

Страница 1: ...Installation Operating Instructions User Guide T3 OPPAD TFT Remote Keypad IP55...

Страница 2: ...standard 2 wire 5V differential Operational 10 50 C Storage 40 C 60 C 95 non condensing IP55 25m 82 5ft shielded twisted pair Mechanical Installation Dimensions 1 10mm 100mm 90mm 80mm Through Panel M...

Страница 3: ...Operating Information Provides a real time display of key operating information e g output current and power Quick Help Button Provides access to short description of the displayed messages Function B...

Страница 4: ...PPAD is used on networks with multiple drives the user can change the drive address to set up communication with another drive in the same drive network at anytime Select Drive Address xx Select Drive...

Страница 5: ...9kW 23 7Hz 23 7Hz 15 3A 23 7Hz 15 3A Drive Inhibited The STO connections are not made Drive Stopped Disabled Drive is enabled running display shows the output frequency Hz Press the Navigate key to se...

Страница 6: ...equired parameter Display will show the present parameter value on the lower line of the display Press the Navigate key for 1 second Adjust the value using the Up and Down keys Display will show the m...

Страница 7: ...ting the T3 OPPAD ID 1 or 2 so that two T3 OPPADs can be connected to a single drive or network of multiple drives Troubleshooting Symptom Explanation Select drive address xx displayed after SCAN mess...

Страница 8: ...82 OPTFT IN_V2 00 82 OPTFT IN_V2 00 Bardac Drives 40 Log Canoe Circle Stevensville MD 21666 410 604 3400 888 667 7333 bardac com driveweb com automationthings com...

Отзывы: