background image

2

   |   

T3-OPPAD

 TFT Remote Keypad IP55 User Guide   |   

Version 1.02

www.

bardac

.com

General Specification

Compatible Drives: 
Signal Interface: 
Supply Input: 
RS485 Signal: 
Environmental: 

Relative Humidity: 
Protection Rating: 
Max Cable Length: 

 E3, P2

,

 V3

CV

 

Standard 8-way RJ45 connector 

24V + / - 10%, DC, 30mA
Industry standard 2-wire +5V differential

 

Operational:  -10 … 50°C 
Storage: 

-40°C … 60°C

< 95% (non condensing)
IP55
25m / 82.5ft shielded twisted pair

Mechanical Installation

Dimensions

110mm

100mm

90mm

80mm

Through Panel Mount

The panel on to which the 

T3-OPPAD

 is to be mounted should 

be cut out in accordance with the diagram below.

110mm

102mm

81mm

Electrical Installation

Cable Requirements

1

1

CAUTION!

 Incorrect cable connection may damage the drive. Extra care should be taken when using third party cable. 

Содержание T3-OPPAD

Страница 1: ...Installation Operating Instructions User Guide T3 OPPAD TFT Remote Keypad IP55...

Страница 2: ...standard 2 wire 5V differential Operational 10 50 C Storage 40 C 60 C 95 non condensing IP55 25m 82 5ft shielded twisted pair Mechanical Installation Dimensions 1 10mm 100mm 90mm 80mm Through Panel M...

Страница 3: ...Operating Information Provides a real time display of key operating information e g output current and power Quick Help Button Provides access to short description of the displayed messages Function B...

Страница 4: ...PPAD is used on networks with multiple drives the user can change the drive address to set up communication with another drive in the same drive network at anytime Select Drive Address xx Select Drive...

Страница 5: ...9kW 23 7Hz 23 7Hz 15 3A 23 7Hz 15 3A Drive Inhibited The STO connections are not made Drive Stopped Disabled Drive is enabled running display shows the output frequency Hz Press the Navigate key to se...

Страница 6: ...equired parameter Display will show the present parameter value on the lower line of the display Press the Navigate key for 1 second Adjust the value using the Up and Down keys Display will show the m...

Страница 7: ...ting the T3 OPPAD ID 1 or 2 so that two T3 OPPADs can be connected to a single drive or network of multiple drives Troubleshooting Symptom Explanation Select drive address xx displayed after SCAN mess...

Страница 8: ...82 OPTFT IN_V2 00 82 OPTFT IN_V2 00 Bardac Drives 40 Log Canoe Circle Stevensville MD 21666 410 604 3400 888 667 7333 bardac com driveweb com automationthings com...

Отзывы: