Manual 2100-640D
Page
16 of 32
TABLE 1
Wall Thermostats
TABLE 2
Humidity Controls
Part Number
Predominate Features
8403-038
(H600A1014)
SPDT switching, pilot duty 50VA @ 24V
Humidity range 20-80% RH
8403-047
(H200-10-21-10)
Electronic dehumidstat SPST closes-on-rise
Humidity range 10-90% with adjustable stops
TABLE 3
CO
2
Controller
Part Number
Predominate Features
8403-067
Normally Open SPST relay closes-on-rise
24V dual wave length sensor. Default setting
950ppm, adjustable to 0-2000ppm
Default off setting 1000ppm, adjustable to
0-200 ppm can be calibrated
TABLE 4
Thermostat Wire Size
Transformer
VA
FLA
Wire Gauge
Maximum
Distance
In Feet
55
2.3
20 gauge
18 gauge
16 gauge
14 gauge
12 gauge
45
60
100
160
250
Part Number
Predominate Features
8403-057
(TH3110D1040)
1 stage Cool, 1 stage Heat; Electronic Non-Programmable; Auto or Manual changeover
8403-058
(TH5220D1151)
2 stage Cool, 2 stage Heat; Electronic Non-Programmable;
HP or Conventional (Default: HP); Auto or Manual changeover
8403-059
(TH5220D1219/U)
2 stage Cool, 2 stage Heat; Electronic Non-Programmable;
HP or Conventional (Default: AC); Auto or Manual changeover
8403-060
(1120-445)
3 stage Cool; 3 stage Heat; Electronic Programmable/Non-Programmable;
HP or Conventional; Auto or Manual changeover; Dehumidification Output
CS9B-THO
3 stage Cool, 3 stage Heat; Programmable/Non-Programmable; HP or Conventional;
Auto or Manual Changeover; Humidity Sensor w/ dehumidification; Motion Sensor w/
Intelligent Learning Control; BACnet-compatible
CS9B-THOC
3 stage Cool, 3 stage Heat; Programmable/Non-Programmable; HP or Conventional;
Auto or Manual Changeover; Humidity Sensor w/ dehumidification; CO
2
Sensor; Motion
Sensor w/Intelligent Learning Control; BACnet-compatible
CS9BE-THO
3 stage Cool, 3 stage Heat; Programmable/Non-Programmable; HP or Conventional;
Auto or Manual Changeover; Humidity Sensor w/ dehumidification; Motion Sensor w/
Intelligent Learning Control; BACnet-compatible; Ethernet-compatible
CS9BE-THOC
3 stage Cool, 3 stage Heat; Programmable/Non-Programmable; HP or Conventional; Auto
or Manual Changeover; Humidity Sensor w/dehumidification; CO
2
Sensor; Motion Sensor
w/Intelligent Learning Control; BACnet-compatible; Ethernet-compatible
8403-089
(T4 Pro)
1 stage Cool, 1 stage Heat – Heat Pump; 1 stage Cool, 1 stage Heat – Conventional
Programmable/Non-Programmable Electronic; Auto or Manual changeover
8403-090
(T6 Pro)
2 stage Cool, 3 stage Heat – Heat Pump; 2 stage Cool, 2 stage Heat – Conventional
Programmable/Non-Programmable Electronic; Auto or Manual changeover