Manual 2100-752B
Page
4 of 49
Q-TEC GENERAL INFORMATION
Q-TEC Model Nomenclature
Shipping Damage
Upon receipt of equipment, the carton should be
checked for external signs of shipping damage. The
skid must remain attached to the unit until the unit is
ready for installation. If damage is found, the receiving
party must contact the last carrier immediately,
preferably in writing, requesting inspection by the
carrier’s agent.
Unit Removal from Skid
It is
not
recommended that the unit be removed from
the skid with a fork lift as the air seal under the unit
could be damaged (see Figure 1).
The shipping brackets on each side of the unit must be
removed and discarded (see Figure 2). The return air
grille panel can be removed to provide a place to hold
the unit.
The unit can be tipped forward and slid down the edge
of the skid until the front wheels touch the ground. The
wheels will not roll as they are shipped from the factory
locked. The back of the skid will have to be held down
to keep it from tipping up. The skid can be slid out
from under the unit. The unit can then be set upright.
!
WARNING
Heavy item hazard.
Use more than one person to handle unit.
Check unit wheels to ensure that wheels are
locked before removing from skid.
Failure to do so could result in unit damage
or serious injury.
ACCESSORIES AND CONTROL
OPTIONS
X – Standard Controls
E – Standard Controls, Low
Ambient Control (LAC)
COIL OPTIONS
X – Standard
1 – Phenolic Coated Evaporator
2 – Phenolic Coated Condenser
3 – Phenolic Coated Evaporator
and Condenser
Q
36
A
4
D A 0Z X P X X X X
MODEL SERIES
FILTER OPTIONS
X – 1" MERV 2 Disposable Filter
M – 2" MERV 11 Disposable Filter
N – 2" MERV 13 Disposable Filter
P – 2" MERV 8 Disposable Filter
B – NPBI TECH + 2" MERV 13 Disposable Filter
A – UV-C + 2" MERV 13 Disposable Filter
PLACEHOLDER
X – Standard Unit
Q – QSP Plenum Option
COLOR OPTIONS
X – Beige Baked Enamel Finish
V – Vinyl Coated
4 – Buckeye Gray Baked Enamel Finish
CAPACITY
36 – 3 Ton
42 – 3½ Ton
48 – 4 Ton
SPECIALTY PRODUCTS
D
– Hot Gas Reheat Dehumidification
REVISION
A –
Air Conditioner
VENTILATION OPTIONS
X – Fresh Air Damper
B – Blank-off Plate
R – Energy Recovery Ventilator
S – Partial Flow Economizer, JADE
V – Commercial Ventilator, Modulating
VOLTS & PHASE
A – 230/208/60/1
B – 230/208/60/3
C – 460/60/3
ELECTRIC HEAT
00 – 0kW with Lug Connection
0Z – 0kW with Circuit Breaker
05 – 15kW with Circuit Breaker
See Electrical Specifications for further details.