Manual 7960-811
Page
6 of 13
1
V
alues listed are with ventilation package disabled
2
Return air temperature °F @ Rated CFM
3
Below 50°F
, unit requires a factory or field installed low ambient control.
4
Suction pr/- 4 psi, Discharge pr/- 10 psi
DB/WB
2
OD T
emp.
65°F
3
70°F
75°F
80°F
85°F
90°F
95°F
100°F
105°F
Mode
A/C
Dehum
A/C
Dehum
A/C
Dehum
A/C
Dehum
A/C
Dehum
A/C
Dehum
A/C
Dehum
A/C
Dehum
A/C
Dehum
75/62.5 (50% RH)
Total Cooling Btuh
39,800
18,700
38,700
16,200
37,500
13,700
36,500
11,100
35,300
8,500
34,200
5,900
33,000
3,200
31,800
400
30,600
Sensible Btuh
29,200
7,100
28,700
5,300
28,200
3,500
27,700
1,600
27,200
(300)
26,600
(2,200)
26,100
(4,200)
25,500
(6,100)
25,000
(8,100)
S/T
0.734
0.380
0.742
0.327
0.752
0.255
0.759
0.144
0.771
0
0.778
0
0.791
0
0.802
0
0.817
0
Latent Btuh
10,600
11,600
10,000
10,900
9,300
10,200
8,800
9,500
8,100
8,800
7,600
8,100
6,900
7,400
6,300
6,500
5,600
5,700
Lbs. H20/hr
.
10.0
10.9
9.4
10.3
8.8
9.6
8.3
9.0
7.6
8.3
7.2
7.6
6.5
7.0
5.9
6.1
5.3
5.4
Supply Air DB
52.0
67.0
52.4
69.0
52.8
71.1
53.3
73.2
53.7
75.4
54.1
77.5
54.4
79.7
54.8
81.9
55.1
84.1
Supply Air WB
50.5
55.1
51.0
56.1
51.3
57.0
51.7
58.1
52.1
59.2
52.4
60.2
52.8
61.3
53.1
62.5
53.4
63.6
Suction PSIG
4
125
119
127
120
128
120
130
122
131
123
133
124
134
126
135
128
137
130
Discharge PSIG
4
287
239
307
254
329
269
351
284
376
300
401
317
427
334
455
352
484
371
75/64.1 (55% RH)
Total Cooling Btuh
40,900
19,800
39,800
17,400
38,600
14,900
37,500
12,300
36,300
9,700
35,200
7,100
34,000
4,400
32,800
1,600
31,700
Sensible Btuh
27,500
6,200
27,000
4,400
26,500
2,500
26,000
700
25,500
(1,200)
25,000
(3,200)
24,500
(5,100)
23,900
(7,000)
23,300
(9,000)
S/T
0.672
0.31
0.678
0.25
0.687
0.17
0.693
0.06
0.702
0
0.710
0
0.721
0
0.729
0
0.735
0
Latent Btuh
13,400
13,600
12,800
13,000
12,100
12,400
11,500
11,600
10,800
10,900
10,200
10,300
9,500
9,500
8,900
8,600
8,400
7,800
Lbs. H20/hr
.
12.6
12.8
12.1
12.3
11.4
11.7
10.8
10.9
10.2
10.3
9.6
9.7
9.0
9.0
8.4
8.1
7.9
7.4
Supply Air DB
53.2
68.0
53.6
70.1
54.1
72.2
54.5
74.3
54.9
76.4
55.3
78.6
55.6
80.7
56.0
83.0
56.4
85.2
Supply Air WB
51.9
56.2
52.3
57.2
52.7
58.2
53.1
59.2
53.5
60.3
53.8
61.3
54.2
62.4
54.5
63.5
54.8
64.7
Suction PSIG
4
128
122
130
123
131
124
133
125
134
126
136
127
137
129
138
131
140
133
Discharge PSIG
4
288
242
309
256
330
271
353
287
377
303
402
320
429
337
457
355
485
373
75/65.5 (60% RH)
Total Cooling Btuh
41,900
21,000
40,800
18,600
39,500
16,100
38,500
13,500
37,400
10,900
36,200
8,300
35,000
5,600
33,900
2,800
32,700
Sensible Btuh
25,900
5,300
25,400
3,500
24,900
1,700
24,400
(300)
23,900
(2,100)
23,400
(4,100)
22,800
(6,000)
22,300
(7,900)
21,700
(9,900)
S/T
0.618
0.252
0.623
0.188
0.630
0.106
0.634
0
0.639
0
0.646
0
0.651
0
0.658
0
0.664
0
Latent Btuh
16,000
15,700
15,400
15,100
14,600
14,400
14,100
13,800
13,500
13,000
12,800
12,400
12,200
11,600
11,600
10,700
11,000
9,900
Lbs. H20/hr
.
15.1
14.8
14.5
14.2
13.8
13.6
13.3
13.0
12.7
12.3
12.1
11.7
11.5
10.9
10.9
10.1
10.4
9.3
Supply Air DB
54.4
69.1
54.9
71.1
55.2
73.2
55.7
75.3
56.1
77.4
56.5
79.6
56.9
81.8
57.2
84.0
57.6
86.2
Supply Air WB
53.3
57.3
53.7
58.3
54.0
59.2
54.5
60.3
54.8
61.3
55.2
62.4
55.5
63.5
55.9
64.6
56.2
65.8
Suction PSIG
4
131
125
133
126
134
126
136
128
137
129
138
130
140
132
141
134
143
136
Discharge PSIG
4
290
245
310
259
332
274
355
290
379
306
404
322
431
340
458
358
487
376
75/66.7 (65% RH)
Total Cooling Btuh
42,900
22,200
41,800
19,800
40,600
17,300
39,500
14,700
38,400
12,100
37,200
9,500
36,100
6,800
34,900
4,000
33,700
1,200
Sensible Btuh
24,200
4,400
23,800
2,600
23,300
700
22,800
(1,200)
22,200
(3,100)
21,700
(5,000)
21,200
(6,900)
20,600
(8,800)
20,100
(10,800)
S/T
0.564
0.20
0.569
0.13
0.574
0.04
0.577
0
0.578
0
0.583
0
0.587
0
0.590
0
0.596
0
Latent Btuh
18,700
17,800
18,000
17,200
17,300
16,600
16,700
15,900
16,200
15,200
15,500
14,500
14,900
13,700
14,300
12,800
13,600
12,000
Lbs. H20/hr
.
17.6
16.8
17.0
16.2
16.3
15.7
15.8
15.0
15.3
14.3
14.6
13.7
14.1
12.9
13.5
12.1
12.8
11.3
Supply Air DB
55.7
70.1
56.1
72.2
56.5
74.2
56.9
76.3
57.3
78.5
57.7
80.6
58.1
82.8
58.4
85.0
58.8
87.3
Supply Air WB
54.7
58.4
55.1
59.4
55.4
60.3
55.8
61.4
56.2
62.4
56.6
63.5
56.9
64.6
57.2
65.7
57.5
66.9
Suction PSIG
4
134
128
136
129
137
129
139
131
140
132
141
133
143
135
144
137
146
139
Discharge PSIG
4
292
247
312
262
334
277
356
292
380
308
406
325
432
342
460
360
489
379
75/68 (70%
RH)
Total Cooling Btuh
43,900
23,400
42,800
21,000
41,600
18,500
40,600
15,900
39,400
13,300
38,300
10,600
37,100
7,900
35,900
5,200
34,700
2,400
Sensible Btuh
22,600
3,500
22,100
1,700
21,700
(200)
21,100
(2,100)
20,600
(4,000)
20,100
(5,900)
19,500
(7,800)
19,000
(9,700)
18,400
(11,700)
S/T
0.515
0.150
0.516
0.081
0.522
0
0.520
0
0.523
0
0.525
0
0.526
0
0.529
0
0.530
0
Latent Btuh
21,300
19,900
20,700
19,300
19,900
18,700
19,500
18,000
18,800
17,300
18,200
16,500
17,600
15,700
16,900
14,900
16,300
14,100
Lbs. H20/hr
.
20.1
18.8
19.5
18.2
18.8
17.6
18.4
17.0
17.7
16.3
17.2
15.6
16.6
14.8
15.9
14.1
15.4
13.3
Supply Air DB
56.9
71.1
57.3
73.2
57.7
75.2
58.1
77.4
58.5
79.5
58.9
81.7
59.3
83.9
59.7
86.1
60.0
88.3
Supply Air WB
56.0
59.5
56.4
60.4
56.7
61.4
57.2
62.5
57.6
63.5
57.9
64.6
58.3
65.7
58.6
66.8
58.9
68.0
Suction PSIG
4
137
131
139
132
140
132
142
134
143
135
144
136
146
138
147
140
149
142
Discharge PSIG
4
293
250
314
264
335
279
358
295
382
311
407
328
434
345
462
363
490
382
80/68.3 (55% RH)
Total Cooling Btuh
44,300
24,700
43,200
22,200
42,000
19,700
41,000
17,200
39,800
14,600
38,700
11,900
37,500
9,200
36,300
6,500
35,100
3,700
Sensible Btuh
28,800
7,600
28,300
5,800
27,800
3,900
27,300
2,000
26,800
100
26,200
(1,800)
25,700
(3,700)
25,200
(5,700)
24,600
(7,600)
S/T
0.650
0.31
0.655
0.26
0.662
0.20
0.666
0.12
0.673
0.01
0.677
0
0.685
0
0.694
0
0.701
0
Latent Btuh
15,500
17,100
14,900
16,400
14,200
15,800
13,700
15,200
13,000
14,500
12,500
13,700
11,800
12,900
11,100
12,200
10,500
11,300
Lbs. H20/hr
.
14.6
16.1
14.1
15.5
13.4
14.9
12.9
14.3
12.3
13.7
11.8
12.9
11.1
12.2
10.5
11.5
9.9
10.7
Supply Air DB
57.6
72.1
58.0
74.2
58.4
76.2
58.9
78.4
59.3
80.5
59.6
82.6
60.0
84.8
60.4
87.0
60.7
89.3
Supply Air WB
56.4
59.5
56.8
60.5
57.1
61.4
57.5
62.5
57.9
63.5
58.3
64.6
58.6
65.7
58.9
66.8
59.2
68.0
Suction PSIG
4
138
133
140
134
141
134
143
136
144
137
145
139
147
140
148
142
150
144
Discharge PSIG
4
293
250
313
265
335
280
357
295
381
311
407
328
433
345
461
363
490
382
W36ABDA Cooling and Dehumidification Application Data
1
Содержание 11EER WA W18AB-A
Страница 2: ......
Страница 24: ......
Страница 67: ......
Страница 71: ...Manual 2110 1449H Page 4 of 12 FUNCTIONAL COMPONENTS 10 11 2 3 1 4 5 6 9 8 7 12 13 14 15 SEXP 949...
Страница 75: ...Manual 2110 1449H Page 8 of 12 CONTROL PANEL 14 13 6 15 18 16 4 11 7 10 9 1 3 12 17 5 2 SEXP 908...
Страница 77: ...Manual 2110 1449H Page 10 of 12 CONTROL PANEL 7 17 11 12 16 3 10 8 13 15 14 9 4 5 6 18 1 2 SEXP 948...
Страница 80: ......
Страница 83: ......
Страница 97: ......