17. Switch Mode Power Supply (SMPS) R764349
Connector : J619 – to Lamp Power Supply (secondary)
Pin Name
Pin No
In/Out
Description
Signal
++5V
1
O
+5V Power Supply StandBy
+5VDC
GND
2
Earth (secondary)
SCL
3
I/O
Serial Clock line
0/5VDC
SDA
4
I/O
Serial Data line
0/5VDC
/ERROR
5
O
Drops to low level when the NTC sensor in Open
collector drain the Lamp house exceeds predefined
temperature range
Open collector drain
6
not used
Connector : J601 – to Backplane (secondary)
Pin Name
Pin No
In/Out
Description
Signal
++3.3V
1,2,3
O
+3.3V Power Supply
+3.3VDC
+5V
4
O
+5V Power Supply
+5VDC
GND
5,6,7,8
Earth (secondary)
GND
a..a10
Earth (secondary)
RET_FAN
a11..a16
I
Tacho input Fan FAN_LAMP
FAN_LAMP_CTRLb1
I
Tacho input Fan FAN_LAMP
0/5VDC
TILT_SW
b2
I
Tilt Switch
0/5VDC
3V3_SENSE
b3/b4
I
Remote sense 3.3V
3.3VDC
NTC_LAMP
b5
I
NTC sensor input
0..5VDC
T_AMB
b6
I
Analog Voltage, measure for ambiant 0.1V/°C
temperature
0.1V/°C
SDA_STBY
b7
I/O
Serial Data line
0/5V
SCL_STBY
b8
I/O
Serial Clock line
0/5V
MICRO_SW
b9
I
Microswitch
0/5V
FAN-
MIRR_CTRL
b10
I
Tacho input Fan FAN_MIRROR
0/5VDC
RES_IN
b11
I
Spare input
0/5VDC
PWR_GOOD
b12
O
Signal that indicates the presence of the mains
voltage and that the power v3.3V and +5V
are within predefined range.
FAN_LAMP
b13
O
Current output to FAN Lamp
16...28VDC
FAN_MIRR
b14
O
Current output to FAN Mirror
16...28VDC
TEC
b15,b16
O
Current output to Thermo electric cooling
+9...+16VDC
++5V
c1
O
5V StandBy output
+5VDC
+12V
c2
O
12V output
+12VDC
+15V
c3
O
15V output
+15VDC
+30V
c4
O
30V output
+30VDC
+12V AMB
c5
O
12V output to Ambiant Temp. Sensor
+12VDC
136
R5976820 SLM R12+ PERFORMER 08/03/2005
Содержание SLM R12 Plus
Страница 1: ...SLM R12 Performer Service Manual R9010170 R9010171 R5976820 00 08 03 2005...
Страница 8: ...Table of contents 6 R5976820 SLM R12 PERFORMER 08 03 2005...
Страница 12: ...1 Safety 10 R5976820 SLM R12 PERFORMER 08 03 2005...
Страница 36: ...5 SLM R12 P Location of the Fans 34 R5976820 SLM R12 PERFORMER 08 03 2005...
Страница 56: ...8 Local Keypad LCD Display 54 R5976820 SLM R12 PERFORMER 08 03 2005...
Страница 82: ...11 Signal Input Selection R763850 R763851 80 R5976820 SLM R12 PERFORMER 08 03 2005...
Страница 90: ...13 Digital Inputs Backplane R763378 88 R5976820 SLM R12 PERFORMER 08 03 2005...
Страница 126: ...15 Lamp Power Supply R7633705 124 R5976820 SLM R12 PERFORMER 08 03 2005...
Страница 130: ...16 Start Pulse Generator SPG R763512 128 R5976820 SLM R12 PERFORMER 08 03 2005...
Страница 168: ...22 Infra Red Receiver Module R763261 166 R5976820 SLM R12 PERFORMER 08 03 2005...
Страница 174: ...24 Projector Tilt Switch R764240 172 R5976820 SLM R12 PERFORMER 08 03 2005...
Страница 178: ...25 Light Output Sensor R763294 176 R5976820 SLM R12 PERFORMER 08 03 2005...
Страница 182: ...26 Lamp Info Module R763295 180 R5976820 SLM R12 PERFORMER 08 03 2005...
Страница 258: ...27 Maintenance 256 R5976820 SLM R12 PERFORMER 08 03 2005...
Страница 274: ...29 Overview of the Electrical Diagrams 272 R5976820 SLM R12 PERFORMER 08 03 2005...
Страница 280: ...Index 278 R5976820 SLM R12 PERFORMER 08 03 2005...