– 20 –
Command:
w_LCA str
Registration of Location displayed by WEB
r_LCA
Reading of Location displayed by WEB
Function:
These commands register/read a location.
These commands’ character strings are displayed for the Location on the WEB.
“str” is an ASCII character string using maximum of 32 characters.
Small letters are converted into capital letters (i.e., not case sensitive).
Command:
s_ETHON
Turns the Ethernet function on.
s_ETHOFF
Turns the Ethernet function off.
Function:
These commands set Ethernet on/off.
For the RS-232C, both commands work to turn on/off alternately. But for Telnet
and FTP, if you set Ethernet off, the Ethernet function is restored only by re-
setting from the Setup menu of this unit or by re-setting the power source.
Communications Related Commands