6. Power status LED

Off: Display not powered, or display operational but power LED function disabled in OSD (see

“Power

LED”, page 24

)

Steady white: Display operational

Slow blinking amber: Display in suspend mode (requires DPMS mode to be enabled in the OSD menu,
see

“DPMS mode”, page 25

)

Fast blinking amber: Display in standby mode (requires DPMS mode to be enabled in the OSD menu,
see

“DPMS mode”, page 25

)

Steady amber: Display switched off via the standby key, or display in hibernate mode (requires DPMS
mode and Hibernate to be enabled in the OSD menu, see

“DPMS mode”, page 25

and

“Hibernate”,

page 26

)

7. Ambient light sensor (option SPEF only)
8. I-Guard Front sensor

Back

9

8

10

11

12

1

2

3

5

6

4

7

CHANNEL 2

CHANNEL 1

Image 1–2

1. +24 VDC power input
2. Channel 2 DisplayPort video input
3. Channel 2 DVI video input
4. Channel 1 DisplayPort video input
5. Channel 1 DVI video input
6. USB-B 2.0 upstream connector

1

7. USB-A 2.0 downstream connectors (2x)
8. Connector compartment cover
9. Kensington security lock
10. VESA mount cover plate
11. Cable duct
12. Foot lock clip

Welcome!

1.

Always connect the display(s) to a USB 3.0 hub, or if unavailable, to a USB 2.0 hub but then no more than two displays can be
connected to the same hub.

Содержание Nio 5.8MP Gray

Страница 1: ...ENABLING BRIGHT OUTCOMES MDNG 6221 option SNEF MDNG 6221 option SPEF MDNG 6221 option NC EM User Guide 5 8MP high bright display Nio 5 8MP Gray...

Страница 2: ...Registered office Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com en support www barco com Barco NV Beneluxpark 21 8500 Kortrijk Belgium www barco com en support www barco com...

Страница 3: ...ons for daily operation 18 3 2 Key indicator lights 18 3 3 Standby switching 19 3 4 OSD menu access 19 3 5 OSD menu navigation 19 3 6 I Luminate 20 3 7 Viewing mode 20 4 Advanced operation 23 4 1 OSD...

Страница 4: ...2 4 18 Image scaling 32 4 19 Image source selection 32 4 20 Grayscale conversion modes 34 4 21 EDID format 34 4 22 EDID timings 34 4 23 Display info 35 4 24 Display status 35 5 Cleaning the display 37...

Страница 5: ...5 K5902142 07 Nio 5 8MP Gray Welcome 1...

Страница 6: ...s available on the documentation disc Keep your original packaging It is designed for this display and is the ideal protection during transport and storage If your product arrived with shipping damage...

Страница 7: ...MS mode and Hibernate to be enabled in the OSD menu see DPMS mode page 25 and Hibernate page 26 7 Ambient light sensor option SPEF only 8 I Guard Front sensor Back 9 8 10 11 12 1 2 3 5 6 4 7 CHANNEL 2...

Страница 8: ...K5902142 07 Nio 5 8MP Gray 8 Welcome...

Страница 9: ...9 K5902142 07 Nio 5 8MP Gray Installation 2...

Страница 10: ...it is included in the box of your display For more information and installation instructions please check the Barco Display Controller and Intuitive Workflow Tools user guide on the included document...

Страница 11: ...screen the result depends on the graphic board and the resolution of the image In some cases the image will be rotated automatically in other cases it will not be rotated e g when pixels would be lost...

Страница 12: ...2 CHANNEL 1 Image 2 5 3 Connect the workstation s USB host to the USB upstream connector on the display if you want to make use of QAWeb or any of the display USB downstream connectors e g to connect...

Страница 13: ...ow Tools are designed to increase visibility of subtle details improve focus during reading sessions and accelerate workflow To install the MXRT driver and Intuitive Workflow Tools 1 Switch on your Ni...

Страница 14: ...Web visit www barco com support medical qaweb to obtain the installation package and user documentation 2 6 VESA mount installation CAUTION Use suitable mounting apparatus to avoid risk of injury WARN...

Страница 15: ...mage 2 11 4 Slide the plastic cover over the neck of the foot Image 2 12 5 Remove the four screws fixing the foot while supporting the foot Image 2 13 6 Attach the arm stand firmly to the panel using...

Страница 16: ...K5902142 07 Nio 5 8MP Gray 16 Installation...

Страница 17: ...17 K5902142 07 Nio 5 8MP Gray Daily operation 3...

Страница 18: ...pixels As a normal tolerance in the manufacturing of the LCD a limited number of these pixels may remain either dark or permanently lit without affecting the diagnostic performance of the product To e...

Страница 19: ...it was in before the power interruption i e standby or on This protects your display against inadvertent image retention problems 3 4 OSD menu access About the OSD menu The OSD menu allows you to con...

Страница 20: ...witch off I Luminate mode and return to normal mode I Luminate mode will automatically switch off after 1 minute I Luminate is only applicable for the SNEF and SPEF versions 3 7 Viewing mode About vie...

Страница 21: ...2 07 Nio 5 8MP Gray To quickly change the viewing mode Press the Left I Luminate and Right key simultaneously during normal operation while the OSD menu is not active to change the viewing mode Daily...

Страница 22: ...K5902142 07 Nio 5 8MP Gray 22 Daily operation...

Страница 23: ...how to change and configure them Certain OSD menu settings affecting calibration can be managed by QAWeb Manually changing these settings in the OSD menu is still possible but the changes will be over...

Страница 24: ...nfirm 4 3 Power LED About the power LED To prevent distractions the power LED is off by default when the display is switched on and used in normal operation This behavior can be changed so that the po...

Страница 25: ...er lock function 1 Bring up the OSD main menu 2 Navigate to the Configuration User Interface Controls menu 3 Enter the Power Lock submenu 4 Select Enabled Disabled as desired and confirm 4 6 DPMS mode...

Страница 26: ...nd confirm To adjust the hibernate time out 1 Bring up the OSD main menu 2 Navigate to the Configuration Power Management menu 3 Enter the Hibernate Timeout submenu 4 Set the time out value as desired...

Страница 27: ...luminance target 1 Bring up the OSD main menu 2 Navigate to the Configuration Calibration menu 3 Enter the Luminance Target submenu 4 Set a luminance target value as desired and confirm The default f...

Страница 28: ...d to improve the quality and communication of digital images in radiology In short the DICOM display function results in more visible grayscales in the images Barco recommends selecting the DICOM disp...

Страница 29: ...ach of these reading rooms are defined by following parameters the maximum light allowed in this type of room the preset ambient light correction value for this reading room These parameters are store...

Страница 30: ...us report About DICOM status report Following information is available DICOM Compliance Status status since last compliance check Compliance status Shows if the current DICOM curve is compliant or not...

Страница 31: ...on to start the calibration Warning Pressing a key during calibration will abort the calibration previous values will be restored Note After calibration the compliance check will start automatically 4...

Страница 32: ...age source video input signal Image scaling is only possible when the resolution of your display s video input signal is less than or equal to half the maximum resolution of the display To enable disa...

Страница 33: ...te to the Configuration Image Sources menu 3 Enter the Image Source Selection submenu and select One Image Source 4 Enter the Image Source submenu and select one of the image sources To enable expert...

Страница 34: ...SD main menu 2 Navigate to the Configuration Image Sources Input Settings DisplayPort 1 2 DVI 1 2 menu 3 Enter the Grayscale Conversion submenu 4 Select one of the available color conversion modes and...

Страница 35: ...to make the information visible on the screen 4 24 Display status About display status The Status submenu of the OSD menu provides info on the current status of your display runtimes temperatures etc...

Страница 36: ...K5902142 07 Nio 5 8MP Gray 36 Advanced operation...

Страница 37: ...37 K5902142 07 Nio 5 8MP Gray Cleaning the display 5...

Страница 38: ...t a certain cleaning product use plain water Do not use any of the following products Alcohol in concentrations 70 Strong alkalis lye strong solvents Acetone Toluene Acids Detergents containing fluori...

Страница 39: ...39 K5902142 07 Nio 5 8MP Gray Important information 6...

Страница 40: ...applied part The equipment shall not be used with life support equipment The user should not touch the equipment nor its signal input ports SIP signal output ports SOP and the patient at the same time...

Страница 41: ...ury to a child or adult and serious damage to the device Malfunctions Disconnect the equipment s power cord from the AC inlet and refer servicing to qualified service technicians under the following c...

Страница 42: ...details please visit the Barco website at http www barco com AboutBarco weee Turkey RoHS compliance T rkiye Cumhuriyeti AEEE Y netmeli ine Uygundur Republic of Turkey In conformity with the WEEE Regu...

Страница 43: ...nd marked with the Environmental Friendly Use Period EFUP logo The number inside the EFUP logo that Barco uses please refer to the photo is based on the General guidelines of environment friendly use...

Страница 44: ...ules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause...

Страница 45: ...below The customer or the user of the Nio 5 8MP Gray should assure that it is used in such an environment Emissions test Compliance Electromagnetic environment Guidance RF emissions CISPR 11 Group 1 T...

Страница 46: ...ltage for 0 5 period at 0 45 90 135 180 225 270 and 315 0 residual voltage for 1 period at 0 70 residual voltage for 25 periods at 0 Voltage interruptions 0 residual voltage for 250 periods at 0 0 res...

Страница 47: ...2400 2570 Bluetooth WLAN 802 11 b g n RFID 2450 LTE Band 7 Pulse modulation 217 Hz 2 0 3 28 5240 5100 5800 W LAN 802 11 a n Pulse modulation 217 Hz 0 2 0 3 9 5500 5785 6 6 Explanation of symbols Symbo...

Страница 48: ...egulations Indicates the device is approved according to the PSE regulations Indicates the device is approved according to the RCM regulations Indicates the device is approved according to the EAC reg...

Страница 49: ...Unique Device Identifier REP EC Indicates the Authorised Representative for the European Union REP CH Indicates the Authorised Representative for Switzerland Warning dangerous voltage Caution Consult...

Страница 50: ...cates the maximum number of identical boxes which may be stacked on each other where n is the limiting number xx yy Kg or xx yy xx yy Indicates the weight of the box and that it should be carried with...

Страница 51: ...otocopying taping or information storage and retrieval systems without written permission of Barco 2022 Barco NV all rights reserved Patent protection Please refer to www barco com about barco legal p...

Страница 52: ...irements This device shall only be powered by the following medical approved power supplies Adapter Technology type CMD160 P240 Ratings marked on the medical power supply Input rating 100 240 VAC 1 9...

Страница 53: ...8 1 2018 EN IEC 62368 1 2020 IEC 60601 1 2005 A1 2012 EN 60601 1 2006 A1 2013 A12 2014 ANSI AAMI ES 60601 1 2005 R1 2012 CAN CSA C22 2 No 60601 1 14 EMI specific IEC 60601 1 2 2014 ed4 EN 60601 1 2 20...

Страница 54: ...ance 650 cd m DICOM calibrated luminance 500 cd m Contrast ratio panel typical 1400 1 Response time Tr Tf 2 typical 12 5 ms Housing color RAL 9003 RAL 9004 Video input signals DVI D Dual Link 2x Displ...

Страница 55: ...numbers K9300371B BIS India Safety specific IEC 60950 1 2005 A1 2009 EN 60950 1 2006 A1 2010 A11 2009 A12 2011 A2 2013 IEC 62368 1 2018 EN IEC 62368 1 2020 IEC 60601 1 2005 A1 2012 EN 60601 1 2006 A1...

Страница 56: ...K5902142 07 Nio 5 8MP Gray 56 Operating humidity 8 to 80 non condensing Storage humidity 5 to 85 non condensing Operating pressure 70 kPa minimum Storage pressure 50 to 106 kPa Important information...