6. Tile reassembling
6.7
Installing the power unit
The power unit can be mounted upon the power support plate while the plate is either mounted or not mounted
inside the tile.
Necessary tools
•
Torx T20.
•
7 mm nut driver.
How to install the power unit upon the power support plate ?
1. Place the power unit (J) upon the power support plate (I) as illustrated. The power socket must be in the lower right corner.
2. Is the power support plate mounted upon the module base plate (F) ?
If yes, fasten the power unit with seven screws (P) to the power support plate and the module base plate (F).
Caution:
The screw in the lower right corner, nearby the power socket, must contains a toothed lock washer (O). This lock
washer ensures a good grounding between the power unit and the rest of the tile.
Caution:
Be careful with the board to board connectors between the power unit and the controller unit underneath.
O
P
J
F
Image 6-12
If no, fasten the power unit with four screws (P) to the power support plate (I). One screw in every corner.
42
R5976865 ILITE 6/8/10/12 DISPLAY 14/12/2007
Содержание ILite 6
Страница 1: ...ILite 6 8 10 12 display Service manual R5976865 02 14 12 2007...
Страница 4: ......
Страница 6: ...Table of contents 2 R5976865 ILITE 6 8 10 12 DISPLAY 14 12 2007...
Страница 12: ...2 General 8 R5976865 ILITE 6 8 10 12 DISPLAY 14 12 2007...
Страница 16: ...3 Diagnostic 12 R5976865 ILITE 6 8 10 12 DISPLAY 14 12 2007...
Страница 22: ...4 Troubleshooting 18 R5976865 ILITE 6 8 10 12 DISPLAY 14 12 2007...
Страница 45: ...6 Tile reassembling Image 6 11 R5976865 ILITE 6 8 10 12 DISPLAY 14 12 2007 41...
Страница 52: ...6 Tile reassembling 48 R5976865 ILITE 6 8 10 12 DISPLAY 14 12 2007...
Страница 68: ...A On screen display messages 64 R5976865 ILITE 6 8 10 12 DISPLAY 14 12 2007...