4. Troubleshooting
4.3
No image on ILite tile
Troubleshooting check list
Situation
Solution
One red status LED on the re-sync
unit lights up but the green LED in the
middle does not.
The power unit doesn’t receive the ’START’ signal from the re-sync unit or the power
unit is defect. Remove the tile cover and try to start up the power unit manually (see
"Power unit diagnostic", page 11). If successful replace the re-sync unit, otherwise
replace the defect power unit.
The status LED’s of the re-sync unit
indicate an normal operation of the tile
but no content appears on the tile.
Re-sync unit and power unit are operating normally. The cause of the problem is
probably located on the controller unit. Try to update the software of the ILite tile using
the XLite toolset. If the problem remains replace the ILite tile and send it back to
factory for repair.
16
R5976865 ILITE 6/8/10/12 DISPLAY 14/12/2007
Содержание ILite 6
Страница 1: ...ILite 6 8 10 12 display Service manual R5976865 02 14 12 2007...
Страница 4: ......
Страница 6: ...Table of contents 2 R5976865 ILITE 6 8 10 12 DISPLAY 14 12 2007...
Страница 12: ...2 General 8 R5976865 ILITE 6 8 10 12 DISPLAY 14 12 2007...
Страница 16: ...3 Diagnostic 12 R5976865 ILITE 6 8 10 12 DISPLAY 14 12 2007...
Страница 22: ...4 Troubleshooting 18 R5976865 ILITE 6 8 10 12 DISPLAY 14 12 2007...
Страница 45: ...6 Tile reassembling Image 6 11 R5976865 ILITE 6 8 10 12 DISPLAY 14 12 2007 41...
Страница 52: ...6 Tile reassembling 48 R5976865 ILITE 6 8 10 12 DISPLAY 14 12 2007...
Страница 68: ...A On screen display messages 64 R5976865 ILITE 6 8 10 12 DISPLAY 14 12 2007...