5. Troubleshooting
Code 7612: “Blue DMD temp low” (Error)
This error code is probably preceded by the warning code 7613: “Blue DMD temp low”. The same troubleshooting table can be
applied to.
Code 7613: “Blue DMD temp low” (Warning)
Situation
Solution
The electronics of the Light
Processor Unit remains off due to a
low DMD temperature.
Make sure that the ambient temperature is within specs: higher then 10°C (50°F). Let
the projector acclimate. Do not ignite the lamp, otherwise there is a risk for condensate.
Defect temperature sensor
(reference 17 image 5-21) which
measures the temperature of the
DMD of the BLUE channel.
Replace the temperature sensor on the cooling block of the BLUE channel.
17
Image 5-21
Code 7614: “Blue DMD temp high” (Warning)
Situation
Solution
Blocked
fi
lter of the Light Processor
compartment. The other DMD
temperatures are too high as well.
Ensure that the air inlets of the projector are not blocked. Replace a dirty
fi
lter with a
new one.
The liquid cooling circuit of the Light
Processor is not connected with the
main liquid cooling circuit. Most
likely the other DMD temperatures
are too high as well.
Check of the cooling circuit of the Light Processor is connected with the pump and heat
exchanger. See reference 1 & 2 image 5-17.
The wire unit of the temperature
sensor (NTC) of the DMD in the
BLUE channel is disconnected from
the Power Backplane.
Check if the wire unit (reference 19 image 5-18) of the temperature sensor of the DMD in
the BLUE channel is connected with the power distribution board.
The wire units of two temperature
sensors (NTC’s) have been
swapped. While the temperature of
one DMD is too high, the other will
most likely be too low.
Check if the wire units of all temperature sensors (NTC’s) are plugged in there respective
connector sockets on the Power Distribution board. See image 5-18.
•
Reference 16 image 5-18: Light Processor compartment ambient temperature
sensor.
•
Reference 17 image 5-18: Temperature sensor DMD BLUE channel.
•
Reference 18 image 5-18: Temperature sensor DMD GREEN channel.
•
Reference 19 image 5-18: Temperature sensor DMD RED channel.
Malfunction Fan Control board.
Replace the Fan Control Board. See "Replacing the Fan control board", page 278.
Defect temperature sensor
(reference 17 image 5-21) which
measures the temperature of the
DMD of the BLUE channel.
Replace the temperature sensor on the cooling block of the BLUE channel.
Code 7615: “Blue DMD temp high” (Error)
This error code is probably preceded by the warning code 7614: “Blue DMD temp high”. The same troubleshooting table can be
applied to.
58
R5905312 HDF W SERIES 24/01/2013
Содержание HDF W series
Страница 1: ...HDF W series Service manual R5905312 01 24 01 2013 ...
Страница 4: ......
Страница 8: ...Table of contents 4 R5905312 HDF W SERIES 24 01 2013 ...
Страница 12: ...1 Safety 8 R5905312 HDF W SERIES 24 01 2013 ...
Страница 30: ...3 Preventative maintenance actions 26 R5905312 HDF W SERIES 24 01 2013 ...
Страница 35: ...5 Troubleshooting 5 TROUBLESHOOTING R5905312 HDF W SERIES 24 01 2013 31 ...
Страница 36: ...5 Troubleshooting 32 R5905312 HDF W SERIES 24 01 2013 ...
Страница 110: ...6 Removal and installation of the projector covers 106 R5905312 HDF W SERIES 24 01 2013 ...
Страница 111: ...7 Power Input 7 POWER INPUT R5905312 HDF W SERIES 24 01 2013 107 ...
Страница 112: ...7 Power Input 108 R5905312 HDF W SERIES 24 01 2013 ...
Страница 120: ...7 Power Input 116 R5905312 HDF W SERIES 24 01 2013 ...
Страница 172: ...10 Card Cage 168 R5905312 HDF W SERIES 24 01 2013 ...
Страница 182: ...11 Lamp Power Supply 178 R5905312 HDF W SERIES 24 01 2013 ...
Страница 183: ...12 Start Pulse Generator 12 START PULSE GENERATOR R5905312 HDF W SERIES 24 01 2013 179 ...
Страница 184: ...12 Start Pulse Generator 180 R5905312 HDF W SERIES 24 01 2013 ...
Страница 192: ...12 Start Pulse Generator 188 R5905312 HDF W SERIES 24 01 2013 ...
Страница 242: ...14 Lenses and Lens Holder 238 R5905312 HDF W SERIES 24 01 2013 ...
Страница 266: ...15 Liquid cooling circuit Image 15 39 Electrical connection 262 R5905312 HDF W SERIES 24 01 2013 ...
Страница 269: ...15 Liquid cooling circuit Image 15 45 Electrical connection R5905312 HDF W SERIES 24 01 2013 265 ...
Страница 270: ...15 Liquid cooling circuit 266 R5905312 HDF W SERIES 24 01 2013 ...
Страница 274: ...16 Heat exchanger Image 16 5 Remove assembly 270 R5905312 HDF W SERIES 24 01 2013 ...
Страница 280: ...16 Heat exchanger Image 16 13 276 R5905312 HDF W SERIES 24 01 2013 ...
Страница 309: ...19 Board Diagnostic LED s 19 BOARD DIAGNOSTIC LED S R5905312 HDF W SERIES 24 01 2013 305 ...
Страница 310: ...19 Board Diagnostic LED s 306 R5905312 HDF W SERIES 24 01 2013 ...
Страница 328: ...19 Board Diagnostic LED s 324 R5905312 HDF W SERIES 24 01 2013 ...