D. Troubleshooting
Error
code
Description
Error
Warning
Caused by
Action
2802
LPS start failed
Yes
-
LPS (address 0x28)
Replace LPS
2203
BOOST start
failed
Yes
-
LPS (address 0x20)
Replace LPS
2503
BOOST start
failed
Yes
-
LPS (address 0x22)
Replace LPS
2803
BOOST start
failed
Yes
-
LPS (address 0x28)
Replace LPS
2206
Lamp ignition
failed
Yes
-
hot restrike,
lamp with many strikes, maximum
run time exceeded
Let cool down the lamp for at least 3
minutes. Replace the lamp or SPG
with a new one If problem persists,
call a quali
fi
ed service engineer
2506
Lamp ignition
failed
Yes
-
hot restrike,
lamp with many strikes, maximum
run time exceeded
Let cool down the lamp for at least 3
minutes. Replace the lamp or SPG
with a new one If problem persists,
call a quali
fi
ed service engineer
2806
Lamp ignition
failed
Yes
-
hot restrike,
lamp with many strikes, maximum
run time exceeded
Let cool down the lamp for at least 3
minutes. Replace the lamp or SPG
with a new one If problem persists,
call a quali
fi
ed service engineer
2207
Lamp voltage
range
Yes
-
lamp voltage too high or too low
Replace lamp
2507
Lamp voltage
range
Yes
-
lamp voltage too high or too low
Replace lamp
2807
Lamp voltage
range
Yes
-
lamp voltage too high or too low
Replace lamp
2208
Lamp power
range
Yes
-
lamp voltage too high or too low
Replace lamp
2508
Lamp power
range
Yes
-
lamp voltage too high or too low
Replace lamp
2808
Lamp power
range
Yes
-
lamp voltage too high or too low
Replace lamp
4000
Incompatible
hardware
Yes
No
Incompatible hardware used
Change to correct hardware
4199
FIB reset failed
Yes
-
no communication with FIB
Call a quali
fi
ed service engineer
5098
Flash full
Yes
-
Internal Backup device has reached
its maximum capacity
Call a quali
fi
ed service engineer
5097
Flash
management
full
Yes
-
Internal Backup device has reached
its maximum capacity
Call a quali
fi
ed service engineer
5096
Storing
unsuccessful
Yes
-
Storing the custom settings into
internal backup device has failed
If problem persists, call a quali
fi
ed
service engineer
5095
Restoring
unsuccessful
Yes
-
Restoring the custom settings from
internal backup device has failed
If problem persists, call a quali
fi
ed
service engineer
6099
6098
7698
Light pipe temp
high
Yes
Yes
High temperature on light pipe entry
If problem persists, call a quali
fi
ed
service engineer
7697
Light pipe temp
open
Yes
Yes
Temperature sensor on light pipe
not connected
Call a quali
fi
ed service engineer
7696
Light pipe temp
short
Yes
Yes
Temperature sensor on light pipe
shorted
Call a quali
fi
ed service engineer
7695
Red front DMD
temp low
No
Yes
Low temperature on red DMD
Switching on the lamp will heat up
the DMD
214
R5976921 FLM R20+ PERFORMER 15/03/2010
Содержание FLM R20+ Performer
Страница 1: ...FLM R20 Performer Users manual R9004430 R5976921 11 15 03 2010 ...
Страница 34: ...3 Physical installation 30 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Страница 46: ...5 Connections 42 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Страница 62: ...7 Start up of the Adjustment Mode 58 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Страница 72: ...8 Input menu 68 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Страница 98: ...9 Image menu 94 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Страница 114: ...10 Layout menu Image 10 65 Image 10 66 Image 10 67 110 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Страница 120: ...11 Lamp menu 116 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Страница 148: ...12 Alignment menu 144 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Страница 168: ...13 Projector control 164 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Страница 184: ...14 Service menu 180 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Страница 204: ...17 Removal of the projector covers 200 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Страница 208: ...A Dimensions 204 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Страница 216: ...C DMX chart 212 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Страница 224: ...D Troubleshooting 220 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Страница 232: ...F Order info 228 R5976921 FLM R20 PERFORMER 15 03 2010 ...
Страница 240: ...Index 236 R5976921 FLM R20 PERFORMER 15 03 2010 ...