background image

 

 

 

 

 

 

 

 

56.2inch LCD Large Screen Monitor 

 

 

 

 

MDSC8156

 

Содержание FIMI MDSC8156

Страница 1: ...1 56 2inch LCD Large Screen Monitor MDSC8156...

Страница 2: ...n Display PCA Printed Circuit Assembled RFI Radio Frequency Interference SDI Serial Digital Interface SMPTE Society of Motion Picture and Television Engineers SOG Sync On Green monochrome video S VIDE...

Страница 3: ...gical Hazard and Returns 9 2 10 Cleaning Instruction 10 3 DISPOSAL OF THE LCD MONITOR 12 3 1 Directive 2002 96 EC on waste of electrical and electronic equipment WEEE 13 3 2 Directive 2002 95 EC on th...

Страница 4: ...onitor On and Off 29 10 2 4 Brightness Control 29 11 ON SCREEN DISPLAY OSD 30 11 1 Menu structure 30 11 2 OSD Controls ON Screen Display 32 11 2 1 Working in the OSD Menu 32 11 2 2 Main OSD Menu 32 11...

Страница 5: ...adjustments are provided The display can also be controlled by remote through a serial or Ethernet communication link The MDSC8156 shall be supplied with VESA 400 mounting interfaces This monitor foll...

Страница 6: ...language or format The monitor described in this manual has been certified registered by the safety agencies regulatory authorities as model n BA56DS 1 1 EMC Notice 1 1 1 FCC This equipment has been t...

Страница 7: ...O RAIN OR EXCESSIVE MOISTURE THE ENCLOSURE HAS TO BE CHECKED UPON COLLISION DAMAGE REFER TO QUALIFIED SERVICE PERSONNEL 2 1 Power cord Due to the different power cable lengths necessary at system leve...

Страница 8: ...ipherals must follow the requirements of clause 16 of IEC60601 1 3rd ed and Table BBB 201 of IEC 60601 1 1 for the medical electrical systems 2 4 Handling Do not press on or scratch the LCD screen Do...

Страница 9: ...equate backup solution has to be provided at medical system level This monitor can be repaired only by trained service personnel contact your local dealer to get assistance FIMI will make available on...

Страница 10: ...g citric acid Degreasing agent e g acetone methylene chloride trichloroethylene petrol Strong ammonia detergents e g toilet cleaner Chlorine resp Hypochloride detergents e g Chavel water Domestos Solv...

Страница 11: ...oduct Wipe with a soft cotton cloth Cabinet Clean the cabinet using a soft cotton cloth lightly moistened with a recognized cleaning product for medical equipment Repeat with water only Wipe with a so...

Страница 12: ...es in the disposal of the product The monitor s packaging is re usable please retain the packaging for future use Do not dispose of this monitor with general household waste The fluorescent lamps in t...

Страница 13: ...recycling please contact your local city office or your supplier s office For countries outside the European Union Disposal of electrical products in countries outside the European Union should be do...

Страница 14: ...OFF Not illuminated 0 W Factory Setting This step is only executed if Splash Screen feature is enabled 4 TECHNICAL INFORMATION Display Panel supplier Chi Mei Optoelectronics Display Model Name V562D1...

Страница 15: ...utputs 5V x 4 3 5 mm plug near DVI plug Max 1A from each connector total max current 2Amp Mains voltage range 100 240 Vac 50 60Hz 2 5 5 5Amp Ingress Protection only GR version IP21 The degree of prote...

Страница 16: ...16 5 DIMENSIONS MDSC8156 family 1350 814 Bottom View Front View...

Страница 17: ...17 Side View...

Страница 18: ...18 General View for display without protective glass...

Страница 19: ...19 General View for display with protective glass...

Страница 20: ...sure if these equipments require any change of setting 6 1 Position of Use WARNING When positioning this equipment ensure that the mains plug and socket are easily accessible While unpacking the moni...

Страница 21: ...itor is provided with VESA 400 mounting interface evaluated with a safety factor 6 a suitable mechanical suspension has to be provided in the final installation not provided not provided M6 screw s no...

Страница 22: ...22 7 HANDLING PRECAUTIONS The support system of the 56 monitor must be designed in accordance with the requirements of IEC 60601 1 standard appropriate tensile factor...

Страница 23: ...placed in the field the packaging has been studied to be reused the top and bottom covers of the packaging are equal so you can remove the top and use it as the bottom for the return shipping and use...

Страница 24: ...ng AC Power Plug the receptacle end of the cord set into the AC power adapter then plug the power connector of the adapter into the power port of the monitor This power port is located on the back of...

Страница 25: ...wed The 5V is available on the 4 plugs marked with warning labels and on the pin 16 of each DVI connector All the 5V connections are in parallel a maximum current of 500mA can be drawn from each conne...

Страница 26: ...T M D S Pin 24 CK_RX T M D S DVI 2 input Microcross DVI D female connector Pin 1 D2_RX T M D S Pin 13 D3_RX T M D S Pin 2 D2_RX T M D S Pin 14 5V from the video source system Pin 3 GND Data 2 shield P...

Страница 27: ...Pin 22 GND Clock shield Pin 11 GND Data 1 shield Pin 23 CK_RX T M D S Pin 12 D3_RX T M D S Pin 24 CK_RX T M D S RS 232 Main communication interface for FW upgrade monitor management and data exchange...

Страница 28: ...When main menu or sub menu is active it allows to move or scroll to the previous up item or increase the selected parameter Down When main menu or sub menu is active it allows to move or scroll to the...

Страница 29: ...ch when the Mains Switch is switched on again the monitor will execute the initialization phase and then will turn off because it was the stored status just press the Power On Off key to switch on the...

Страница 30: ...UT MODE DVI PWR IN DVI PWR OUT REMAIN LIFE OUT MODE NATIVE DICOM FACTORY DICOM USER COLOR FACTORY COLOR USER A description of the OSD structure is shown below USER SETTING DICOM OFFSET COLOR TEMP GAMM...

Страница 31: ...SABLE 10 1 PRODUCT INFO SERVICE SPLASH SCREEN YES NO INPUT MODE SINGLE LINK DUAL LINK OUTPUT POWER ON OFF KEY LOCK OFF SERVICE FULL LEFT to RIGHT TOP to BOTTOM MODEL PRODUCT NUM SERIAL NUM HW REL FW R...

Страница 32: ...by the upper menu window 5 Press the Esc key to go back to the root OSD menu level and then to exit from the OSD 11 2 2 Main OSD Menu Press the Enter key to display the Main Menu or the request to in...

Страница 33: ...monitor output is corrected according to the color temperature pre setted in the factory 6500 K In the menu the string COLOR is replaced with the current color temperature i e ____6500 K FACTORY ____...

Страница 34: ...ed when in COLOR USER mode GAMMA COMP The color gamma from 1 4 to 3 2 in 0 1 steps can be adjusted when in COLOR USER mode This can be useful i e to adjust the color depending on the type of content d...

Страница 35: ...nd is not a defect TIME OUT OSD When the OSD menu is displayed and no key is pressed it will disappear after the time setted up in this parameter It is possible to choose among the following values 10...

Страница 36: ...ing the meaning of each item of this menu 11 2 7 Product Info MOD Model Type P N Product Number S N Serial Number H W Hardware release F W Firmware release FSL FPGA Single Link firmware release FDL FP...

Страница 37: ...nversion dongles KEY LOCK This allows to enable the key lock at different menu levels If enabled entering the OSD will display a Request for Password window The password is made up by four characters...

Страница 38: ...sword Password KO Password OK NOTE There is no max tentative numbers for inserting the correct password NOTE Default password is 1224 _ _ _ _ _ _ MONITOR INFO OUT MODE USER SETTING OSD SETTING PRODUCT...

Страница 39: ...l 2 Lines Ver Back Porch 45 Lines NOTE The video signals must be synchronous with respect to each other Dual Link Mode 3840x2160 2 x DVI Dual Link inputs each at 1920x2160 60Hz For each 1 3 Dual Link...

Страница 40: ...Tx Data 7 not used 3 Rx Data 8 not used 4 not used 9 not used 5 Ground 13 2 LAN Interface A LAN interface is provided to allow the following function single LAN connection default with connector locat...

Страница 41: ...ode FIMI 00 Technical level yy Year 11 2011 ww Week 01 to 52 nnnnnn progressive number Type number Code number 12NC Model number Manufacturing Date Factory address BARCO K code 14 IDENTIFICATION LABEL...

Страница 42: ...Content MDSC8156 GR full version with protection glass redundant power supply MDSC8156 R light version w o protection glass with redundant power supply MDSC8156 basic version w o protection glass red...

Страница 43: ...ntenance are provided The information should be read carefully WARNING dangerous voltage Disconnect supply before service Compliance with 2002 96 EC WEEE Directive Consult instructions for use Complia...

Страница 44: ...IMI S r l Saronno Italy All rights are reserved Reproduction in whole or in part is prohibited without the written consent of the copyright owner Printed in Italy Rev 1 3 4519 206 1076 1 a451920610761...

Отзывы: