manualshive.com logo in svg
background image

Quick Start Guide — Operators

Maintenance Procedures

Turn the projector off.

Remove the projector’s front and left side covers.

  Cleaning the Intakes and Filters

Vacuum clean all air intakes, and vacuum clean the 
LPS main air intake on the bottom of the projector.

3

Slide the 

out.  Use a vacuum 

cleaner, or clean gently with water (see note below).  
Re-install the filter when complete. 

Slide the 

out.  Use a vacuum cleaner, 

or clean gently with water (see note below).  
Re-install the filter when complete.  

Slide the 

out.  

 Location on C Series.         Location on B Series.

Use a vacuum cleaner, or clean gently with water (see 
note below).  Re-install the filter when complete. 
Re-install all covers, and turn the projector back on. 

  Optical System Maintenance

When needed, clean the 

with a damp lens cloth, 

using distilled water.   Do not use tap water or alcohol.

When needed, clean the 

.

Replace the lamp when the maximum lamp runtime is 
reached and the 

turns blue, or when the 

projector’s light output falls below optimum requirements.  

For full details on all maintenance activities, refer to the 

.

1

2

  Cleaning the Exterior of the Projector

1

Switch off the projector, and unplug the projector from 
the mains power net.

Clean the projector’s outside housing with a damp cloth. 
Stubborn stains may be removed with a cloth that is 
lightly dampened with a mild detergent solution.

2

  Checking the Cooling Liquid Level

Remove the side cover on the light processor side of the projector. 

All Series 2 projectors (except the DP2K-12C) are liquid cooled.  It is important to check the liquid level 
every 3 months.  In the reservoir, the liquid level must be between the 

and 

labels.  A significant 

drop in level indicates a major leak in the cooling system, which will require immediate attention.

Look through the small window in the security cover, and check the liquid level in the reservoir.

If the level is between 

and 

, no action is needed.

If the level is lower than 

, contact the theater’s technician immediately.  He will need 

to start the refill procedure and check for leaks in the cooling system.

:  If you cannot see the fluid level, remove the projector’s top 

cover and shine a flashlight on the reservoir filler cap while looking 
through the small window.

4

6a

5

2

If water is used, ensure that the filter 
is dry before re-installing.  