Installation adjustment mode
7 - 8
5976397 SPLIT PACK REALITY 909 09112001
DIAGONAL IMAGE FOCUSING
1.TURN THE SCREW MARKED 01
TO FOCUS THE IMAGE
DIAGONALLY FROM LEFT
(BOTTOM) TO RIGHT (TOP).
2.TURN THE SCREW MARKED 02
TO FOCUS THE IMAGE
DIAGONALLY FROM LEFT (TOP)
TO RIGHT (BOTTOM).
<ENTER> TO CONTINUE
<EXIT> TO RETURN
menu 1
Sheimpflug adjustment procedure
Press
ENTER
to start the Green adjustment (menu 1).
Example: Sheimpflug adjustment for the red color
The sheimpflug bolts are located on top of the optical block (image 7.7).
1 Equalize diagonally the focus from left (top) to right (bottom) by turning bolt 04 of the projected color (Image 7.7).
2 Equalize now diagonally the focus from left (bottom) to right (top) by turning bolt 05 (Image 7.7).
Finishing
3 Tighten the 6 bolts (image 7.6) on the front of the optical block.
Remarks
To optimize the image focusing, repeat the optical lens focusing.
After finishing the Installation Adjustment Procedure, the main menu returns on the screen.
image 7.7
Sheimpflug Adjustment
Green
Blue
Red
00
02
04
Left
Right
01
03
05
Left
Right
04
05
00
01
02
03
Содержание BarcoReality 909 Split Pack R9040040
Страница 1: ...SPLIT PACK REALITY 909 R9040040 INSTALLATION MANUAL...
Страница 2: ......
Страница 8: ...Table of contents 0 4 5976397 SPLIT PACK REALITY 909 09112001...
Страница 18: ...Packing and dimensions 2 6 5976397 SPLIT PACK REALITY 909 09112001...
Страница 30: ...Installation setup 4 6 5976397 SPLIT PACK REALITY 909 09112001...
Страница 34: ...ACPowerconnections 5 4 5976397 SPLIT PACK REALITY 909 09112001...
Страница 42: ...Sourceconnections 6 8 5976397 SPLIT PACK REALITY 909 09112001...
Страница 58: ...i 2 Index 5976397 SPLIT PACK REALITY 909 09112001...