barbas UNILUX-3300 Скачать руководство пользователя страница 13

13

UNILUX-3  200 L / 200 R / 300  

3.   

INSTALLATION INSTRUCTIONS

3.1.    FITTING THE FIREPLACE

When fi tting one of these fi replace inserts local and/or national regulations 
relating to fi re safety must be followed. In case of doubt, consult the fi re safety 
department of the local fi re brigade, particularly if the fi re is to be fi tted in a home 
with walls and/or fl oors containing fl ammable material. 

The connection of several appliances to a single fl ue/chimney is not allowed.

3.2.  CHIMNEY

If no chimney is immediately available, have one fi tted by a recognised specialist 
only. The chimney must be compliant with local regulations and is particularly 
important because it has a signifi cant bearing on the function of the appliance.
 
Basic rules:

•  A chimney for an open fi re is not, by defi nition, suitable for a closable model 
 

(i.e. an appliance with doors). As a closed appliance draws in much less 
(cold) air, the smoke is hotter. Please have your chimney inspected to see 
whether it is suitable for a closable appliance.

•  The chimney opening must be at least 5 metres above the top of the door 

opening of your appliance.

•  The chimney must protrude at least 40 cm above the apex of a sloping roof 

and at least 1 metre above a fl at roof. In short, the chimney must always end 
in an area with a negative air pressure. Contact your local chimney sweep for 
the exact dimensions of the chimney opening.

•  The internal diameter must not be less than that of the appliance at any point 

(even at the end of the pipe).

•  Avoid bends at all costs. The maximum deviation from the perpendicular is 

45°.

•  Both the dimensions and the construction must meet stringent construction 

standards. Your recognised specialist will be pleased to assist.

•  Contact your fi re insurer to make sure that your policy is in order.

Содержание UNILUX-3300

Страница 1: ...S FOR USE INSTALLATION INSTRUCTIONS UNILUX 3 200 L 200 R 300 EN 13229 NAME OUTPUT DESCRIPTION Unilux 3 200 L 8 0 kW Fireplace insert Unilux 3 200 R 8 0 kW Fireplace insert Unilux 3 300 8 0 kW Fireplac...

Страница 2: ......

Страница 3: ...3 UNILUX 3 200 L 200 R 300 UNILUX 3 200 R...

Страница 4: ...4 UNILUX 3 200 L 200 R 300...

Страница 5: ...sert 22 5 Stoking up for the first time 23 6 Use 6 1 Ventilation 24 6 2 Getting the fire going 24 6 3 While stoking 24 6 4 Heating economically 26 6 5 Cleaning the window 27 7 General hints 7 1 Tips 2...

Страница 6: ...6 UNILUX 3 200 L 200 R 300...

Страница 7: ...you use your fireplace insert the exterior will become hot Always wear the glove or use the accessories supplied when filling etc Protect yourself and others especially children from burns Do not leav...

Страница 8: ...pliance for the first time When you first fire up your appliance there are a number of extra points you should take into account See section 5 In transit some parts of the appliance may have moved fro...

Страница 9: ...ealer Documentation Warranty Manual Attributes Glove Heat resistant up to max 95 C Operating hook Poker 2 LOCATION 2 1 INCLUDED Turn the handle all the way down Door is locked This handle position sho...

Страница 10: ...10 UNILUX 3 200 L 200 R 300 Handle 50 forwards The door releases from its lock and be opened forwards...

Страница 11: ...11 UNILUX 3 200 L 200 R 300 Check whether the ashtray is completely empty Check the operation of the slider for controlling the combustion air...

Страница 12: ...tted and the chimney approved by a specialist The space into which the fire is to be fitted must in no way be damaged The fire must have its own chimney constructed in compliance with current legislat...

Страница 13: ...suitable for a closable model i e an appliance with doors As a closed appliance draws in much less cold air the smoke is hotter Please have your chimney inspected to see whether it is suitable for a c...

Страница 14: ...am above the fitting location heat must not radiate directly onto it An insulation plate must be hung below the beam leaving an air gap between it and the beam of at least 1 cm Always use white unboun...

Страница 15: ...ure that the ventilation supply is open this is particularly important with today s airtight dwellings If the dwelling has mechanical ventilation that creates under pressure in the room where the appl...

Страница 16: ...To do this use a flexible double walled stainless steel chimney for example Slide the appliance into the chimney breast opening Seal the smoke outlet where it joins the chimney so that no soot can ac...

Страница 17: ...pliance Use the four adjustable legs to set the height of the appliance and level off see pictures in section 3 3 2 The appliance may not be installed against a flammable rear wall Make a good seal be...

Страница 18: ...intake and discharge openings for the convection air Don t let walls rest on the appliance Use a steel or concrete lintel Inlet opening appliance combustion air and cold convection air Outlet opening...

Страница 19: ...ast 100 mm thickness will then be sufficient class A1 DIN 4102 compliant See also section 3 3 After four weeks your fire will be ready for use 3 3 4 Connecting the smoke outlet The appliance comes wit...

Страница 20: ...L 200 R 300 Disassembling the smoke outlet top connection Pull the stovepipe or the stainless steel flexible pipe downwards through the appliance and secure it to the smoke outlet connection Stainless...

Страница 21: ...3 200 L 200 R 300 Stovepipe of steel Fix with hose clamp Minimum 2 pieces per connection Push the smoke outlet connection back upwards and secure it in place Replace the brake plate and the complete...

Страница 22: ...dismounted 4 Convection air escape opening permanent 5 Internal panels vermiculite plate Inner lining 6 Ceramic heat proof glass side 7 Grate 8 Ashtray 9 Wood rack side 10 Wood rack front 11 Combusti...

Страница 23: ...it getting scorched causing a bad smell Check again that all moving parts are in order and that loose parts such as the brake plate internal panels grate etc are in the correct position They may have...

Страница 24: ...ters to start the fire If necessary leave also the door ajar for 10 minutes Do not open the door wide as the window will remain cold If the door is shut during this time smoke will condense on the gla...

Страница 25: ...conditions In order to reduce pollution and any other inconvenience we advise not firing up the fire when there is no wind or in foggy misty conditions Smoke development Your fire has been designed t...

Страница 26: ...validate your warranty 6 4 HEATING ECONOMICALLY The most environmentally friendly and economic way of heating with wood is to have your fire hot but calm The ash should appear to glow a soft red orang...

Страница 27: ...00 R 300 6 5 CLEANING THE WINDOW After several burning hours a light deposit may form on the inner side of the window Once the fire has cooled down this deposit can be removed using glass cleaner or c...

Страница 28: ...soot and tar in your chimney which unchecked will increase the risk of chimney fire Keep the door shut when the fire is burning Doing so improves the performance of your fire 8 10 times benefiting th...

Страница 29: ...xcess heat leaving the chimney rather than going into the room Loss through insufficient combustion such as CO carbon monoxide and soot particles Loss through excessive unburnt fuel in the ash The rat...

Страница 30: ...s case too the fuel cannot burn completely More to the point there is not enough air to mix with the flames This has an extra impact on the environment Admitting too much air under the fuel Combustion...

Страница 31: ...inden Unsuitable fuels are Painted bonded chipboard MDF etc or impregnated wood plastic and other flammable waste Stoking a fire with this is completely forbidden The combustion gases released by thes...

Страница 32: ...rheating Burning one layer of wood can lead to varying outputs When used correctly one load will burn in around 45 minutes Putting in too much wood at once can lead to the appliance being overloaded M...

Страница 33: ...which can theoretically be achieved by burning wood Heat radiation Sort of fuel kWh kg Dry wood average 4 3 The heating value of wood 18 7 MJ kg at 0 humidity is not affected by the sort of wood What...

Страница 34: ...els Check annually Clean internal panels as necessary with hand brush Replace panels as necessary Grate Check annually for cracks breakage Sliders flaps Check function annually Convection channels Cle...

Страница 35: ...e vermiculite plate 1 4 internal panel rear L R vermiculite plate 2 5 internal panel rear middle vermiculite plate 1 6 internal panel side R vermiculite plate 1 7 bottom plate R vermiculite plate 1 8...

Страница 36: ...panel R 1 5 wood rack side 1 6 bottom plate R vermiculite plate 1 7 grate 1 8 wood rack front 1 9 ashtray 1 10 bottom plate front vermiculite plate 1 11 glass front 1 12 door 1 13 bottom plate L verm...

Страница 37: ...glass side R 1 4 side panel R 1 5 wood rack side 2 6 bottom plate L R vermiculite plate 2 7 ashtray 1 8 grate 1 9 bottom plate front vermiculite plate 1 10 wood rack front 1 11 glass front 1 12 door...

Страница 38: ...3 200 L 200 R 300 Sequence for replacing the interior of the appliance Remove the grate Remove the ashtray Remove the wood rack in the front Remove the bottom plate in the front Remove the bottom plat...

Страница 39: ...39 UNILUX 3 200 L 200 R 300 Disassemble the air guidance strip Remove the brake plate Lift the brake plate and turn the brake plate bracket to the back...

Страница 40: ...40 UNILUX 3 200 L 200 R 300 Remove the side internal panel Remove the rear internal panel...

Страница 41: ...41 UNILUX 3 200 L 200 R 300 The entire interior is now disassembled The interior is reassembled in the reverse order...

Страница 42: ...42 UNILUX 3 200 L 200 R 300 12 DIMENSIONS 12 1 UNILUX 3 200 L...

Страница 43: ...43 UNILUX 3 200 L 200 R 300 12 2 UNILUX 3 200 R...

Страница 44: ...44 UNILUX 3 200 L 200 R 300 12 3 UNILUX 3 300...

Страница 45: ...ar fire opening h x w 320 x 520 mm Internal panels Vermiculite insulation plates 700 kg m3 1100 C Bottom Vermiculite insulation plates 700 kg m3 1100 C Inner lining Steel heat resistant and rust proof...

Страница 46: ...led gross capacity Efficiency is the percentage of fuel converted into useful heat It is the ratio of net capacity and gross capacity How can I keep the glass clean By making a point of using dry clea...

Страница 47: ...he fuel Move the combustion air supply slider towards the position The primary air supply is now closed Under these conditions the layer of ash should no longer burn bright orange white but red If the...

Страница 48: ...ratures 100 C any moisture still in the wood will evaporate This drying procedure implies a significant loss of energy if wood which is too damp is burnt The right degree of moisture is achieved after...

Страница 49: ...49 UNILUX 3 200 L 200 R 300...

Страница 50: ...50 UNILUX 3 200 L 200 R 300...

Страница 51: ......

Страница 52: ...01 010710 328164 INTERFOCOS B V HALLENSTRAAT 17 5531 AB BLADEL NEDERLAND E mail info barbas nl Internet www barbas com...

Отзывы: