7
Troubleshooting
Table 11: Troubleshooting
Problem
possible cause
solution
The main fire stops to burn
The concentric flue system is
not installed according to the
specified instructions.
Install the concentric flue sys-
tem correctly. Refer to the prep-
aration manual.
An incorrect flue gas restriction
plate is fitted.
Install the correct gas restric-
tion plate. Refer to chapter
Insufficient pressure of the gas
supply.
Contact your gas supplier com-
pany
The concentric system has a
leak. The leak is possibly on
the inside of the concentric flue.
Check the concentric flue sys-
tem. Refer to the preparation
manual for correct installation.
There is no power supply (230
VAC).
Repair the power supply.
The appliance does not react
on the remote control
The batteries of the remote
control are empty.
Replace the batteries. Refer to
the user manual.
The pilot burner stops to burn
There is insufficient exhaust of
the flue gases.
Check the concentric flue sys-
tem. Refer to the preparation
manual for correct installation.
The pilot burner is dirty.
Clean the pilot burner
The pilot burner is defective.
Replace the pilot burner
The thermocouple is defective
Replace the thermocouple
The light does not operate
The light bulb is defective
Replace the light bulb. See
chapter
.
A loud noise occurs in the ap-
pliance
The overpressure hatches are
activated.
Do a check on the appliance for
problems.
The lacquer of the appliance is
damaged
Use an aerosol can with heat
resistant lacquer to repair any
damage in the laquer.
Troubleshooting
Gas Fire Front 70-60
65
Содержание Gas Fire Front 70-60 PF2
Страница 10: ...2 5 Overview of the ceramic log set Figure 3 Overview of ceramic log set Description 10 Gas Fire Front 70 60...
Страница 60: ...3 Slide the strip downwards 4 Tighten the nut wings Maintenance 60 Gas Fire Front 70 60...
Страница 61: ...5 Tilt the top panel upwards 6 Install the front panel and side panels Maintenance Gas Fire Front 70 60 61...
Страница 70: ...9 Dimensions 9 1 Gas Fire Front 70 60 PF2 with Floating Frame Gas connection Dimensions 70 Gas Fire Front 70 60...
Страница 71: ...9 2 Gas Fire Front 70 60 PF2 with Floating Frame Gas connection Dimensions Gas Fire Front 70 60 71...
Страница 74: ...9 5 Gas Fire Front 70 60 PF2 with Hidden Door Gas connection Dimensions 74 Gas Fire Front 70 60...
Страница 75: ...9 6 Gas Fire Front 70 60 PF2 with Hidden Door Gas connection Dimensions Gas Fire Front 70 60 75...
Страница 78: ...9 9 BARBAS Airbox 160 with 4 insert models Dimensions 78 Gas Fire Front 70 60...
Страница 79: ...9 10 BARBAS Airbox 320 with 4 insert models Dimensions Gas Fire Front 70 60 79...
Страница 82: ...11 EU Declaration of Conformity EU Declaration of Conformity 82 Gas Fire Front 70 60...
Страница 83: ...EU Declaration of Conformity Gas Fire Front 70 60 83...
Страница 84: ...Your Barbas dealer 002 21 07 2022 352402 248 002...