background image

11

Declaration of performance

1.

Unique identification code of the product-type

2.

Intended use or uses of the construction product, in 
accordance with the applicable harmonised technical 
specification, as foreseen by the manufacturer

3.

Name, registered trade name or registered trade mark 
and contact address of the manufacturer as required 
pursuant to Article 11(5)

4.

Where applicable, name and contact address of the 
authorised representative whose mandate covers the 
tasks specified in Article 12(2)

5.

System or systems of assessment and verification of 
constancy of performance of the construction product 
as set out in Annex V

6.

In case of the declaration of performance concerning a 
construction product covered by a harmonised 
standard

7.

Declared performance

Fire safety

Distance to combustible materials

Minimum distances, in mm
Insulation thickness rear =

100

Insulation thickness sides =

100

Insulation thickness ceiling =

40

Front = 

1000

Insulation thickness floor =

100

NPD

Thermal output

Energy efficiency

8.

Signed for and on behalf of the manufacturer by:

Danny Baijens, CEO
(Name and function)

Bladel;  September 18, 2018

………………………………………………………………………

(place and date of issue)

(Signature)

The performance of the product identified in point 1 is in conformity with the declared performance in point 7.

This declaration of performance is issued under the sole responsibility of the manufacturer identified in point 3.

Water heating output

- kW

Pass

Nominal heat output

10.2 kW

Room heating output

10.2 kW

Electrical safety

Pass

Cleanability

Pass

Maximum operating pressure

Not applicable

Flue gas temperature at nominal heat output

T = 289 °C

75.4 %

NPD

Pass

Risk of burning fuel falling out

Pass

Declaration of Performance

According to regulation (EU) 305/2011

No.  3.127.003-1 - CPR-2013/07/01

Falcon 66/56

Room heater without hot water supply

Barbas Bellfires BV; Hallenstraat 17; 5531 AB  Bladel; The Netherlands

Not applicable

System 3

The notified laboratory SGS Nederland BV, No. 0608 performed the 
determination of the product type on the basis of type testing under system 3 
and issued test report EZKA/2018-01/00004-7

Harmonized technical specification

EN13229:2001/A2:2004/AC:2007

Essential characteristics

Performance

CO = 0.08 vol%

Emission of combustion products

Mechanical resistance (to carry a chimney/flue)

Surface temperature

Release of dangerous substances

Pass

Declaration of performance

Falcon 66/56

5

Содержание Falcon 66/56

Страница 1: ...I Installation and maintenance manual Falcon 66 56 Serial number Production date 9HUVLRQ QXPEHU 116 DWH 21 8 8...

Страница 2: ...se without the prior written permission of Barbas Bellfires BV This document could contain technical inaccuracies or typographical errors Barbas Bellfires BV reserves the right to revise this document...

Страница 3: ...quirements 16 6 1 1 General requirements 16 6 1 2 Requirements on the installation of the appliance 16 6 1 3 Requirements on the chimney 17 6 2 Preparation for installation 17 6 3 Installation procedu...

Страница 4: ...chnical data 29 9 Dimensions 31 9 1 Frameless appliance 31 9 2 Appliance with built in frame 32 9 3 Appliance with 3 sided classic frame 33 9 4 Appliance with 4 sided classic frame 34 10 Warranty Term...

Страница 5: ...d function Bladel September 18 2018 place and date of issue Signature The performance of the product identified in point 1 is in conformity with the declared performance in point 7 This declaration of...

Страница 6: ...England appliances are exempted by publication on a list by the Secretary of State in accordance with changes made to sections 20 and 21 of the Clean Air Act 1993 by section 15 of the Deregulation Ac...

Страница 7: ...w a typical setup The illustrations are for instructional use only 3 1 How to work with this document 1 Make yourself familiar with the structure and content of the document 2 Read the safety chapter...

Страница 8: ...t the ashes that fall through the grate F Cast iron panels Cover of the rear and sides of the combustion chamber G Heat shield Protects the steel in the top of the appliance against excessive heat rad...

Страница 9: ...pports the lower baffle L Secondary air inlet Combustion air supply through the back wall into the combustion chamber Secondary air is used for clean burning M Air wash inlet Combustion air supply thr...

Страница 10: ...convection air through the convection system Q Convection ventila tor Combustion air inlet box option Cover for the convection ventilator with inlet openings for the com bustion air S Adjustable feet...

Страница 11: ...nded for indoor use to heat the room wherein it is installed Do not use it for other purposes The appliance is intended for use with wood logs or wood briquettes as fuel Do not use other fuels The app...

Страница 12: ...installation room or from external N Note The appliance is a room sealed appliance when combustion air comes from the outer side of the building through a flexible pipe that is connected to the combu...

Страница 13: ...ir inlet box and the outer side of the house B Convection air inlet opening Provides air for the convection ventilator A flexible aluminum pipe is connected between the convection air inlet opening an...

Страница 14: ...I Item Description I Flexible aluminum pipe convection set option Extracts the heated convection air from the appliance Description 14 Falcon 66 56...

Страница 15: ...Manual Do not use masking tape on the appliance Masking tape can damage the finish of the appliance Do not use fiberglass rockwool or any other sort of insulation material These materials produce a pu...

Страница 16: ...properly ventilated 6 1 2 Requirements on the installation of the appliance Do not install the appliance against a combustible rear wall or combustible side wall The appliance must be installed minimu...

Страница 17: ...2 bends of 45 The chimney outlet must be at least 5 meter above the top of the appliance The chimney outlet must be at least 40 cm above the top of a sloped roof The chimney outlet must be at least 1...

Страница 18: ...mes You can use the carrying tubes to move the appliance 2 Install the appliance Make sure the distance between the appliance and rear wall is approximately 10 cm minimum 3 Remove the carrying tubes a...

Страница 19: ...prove the performance of the appliance 1 Connect the flue to the flue gas connection on the appliance If necessary use a steel flue adaptor 2 If a flexible stainless steel flue is used secure the flue...

Страница 20: ...er vapor condensation in the appliance when not in use 1 Identify the location in the outer wall or in the floor to a ventilated crawl space for the external combustion air supply inlet 2 Make a hole...

Страница 21: ...e inlet opening d Connect a flexible aluminum pipe B on the collar adaptor A Use a hose clamp 2 Connect the flexible aluminum pipe to a fitting box in the chimney breast 3 On the appliance remove the...

Страница 22: ...iance Keep approximately 10 cm free between the front of the appliance and the front of the fireplace 6 3 7 Build the fireplace Caution If the appliance is placed against a load bearing wall or a comb...

Страница 23: ...east 50 mm from a combustible ceiling Table 7 Installation against a combustible ceiling Item Description A Appliance B Ventilation air outlet Outlet of heated air from the chimney breast C Insulation...

Страница 24: ...inlets b If applicable install the fitting boxes of the convection air inlets c If applicable install the dimmer of the convection ventilator 5 If applicable install a mantle iron to support the brick...

Страница 25: ...upply is not blocked by leaves or other debris 2 Clean the inlet of the pipe of the external combustion air supply 7 3 Convection air system Note Do the procedure in this section only when a convectio...

Страница 26: ...ttached to the socket screw 2 Push up 1 the front of the heat shield and pull it forward 2 and move downward to a vertical position 3 3 Remove the heat shield from the appliance 7 5 2 Remove the lower...

Страница 27: ...upper baffle over the support 5 Lower the right side of the upper baffle and remove it from the appliance 7 6 Place the baffles Do all procedures of 7 5 in reverse order 1 Place the upper baffle Make...

Страница 28: ...Annual maintenance 2 28 Falcon 66 56...

Страница 29: ...eak rate at 10 Pa 1 0 m3 h at 273 K 1013 hPa Emissions at 13 O2 273 K 1013 hPa carbon monoxide CO 0 08 vol 1027 mg Nm3 particles PM 30 mg Nm3 organic gaseous compounds OGC 71 mg Nm3 nitrogen oxides NO...

Страница 30: ...5 mm on the optional convection ventilator combus tion air inlet box O Options Convection ventilator combustion air inlet box Combustion air inlet box Set of 2 adjustable height frames Electrical ener...

Страница 31: ...9 9 Dimensions 9 1 Frameless appliance Dimensions Falcon 66 56 31...

Страница 32: ...9 9 2 Appliance with built in frame With optional convection ventilator combustion air box Dimensions 32 Falcon 66 56...

Страница 33: ...9 9 3 Appliance with 3 sided classic frame Dimensions Falcon 66 56 33...

Страница 34: ...9 9 4 Appliance with 4 sided classic frame Dimensions 34 Falcon 66 56...

Страница 35: ...they have manifested themselves 3 Complaints will only be accepted if they are reported to the Barbas dealer together with the serial number of the Barbas appliance which is stated on the front of the...

Страница 36: ...oes not automatically imply that Barbas Bellfires B V also accepts liability for any possible damage The liability of Barbas Bellfires B V never extends further than that stated in these warranty cond...

Страница 37: ...Warranty Terms Falcon 66 56 3 37...

Страница 38: ...Warranty Terms 3 38 Falcon 66 56...

Страница 39: ...Warranty Terms Falcon 66 56 3 39...

Страница 40: ...Y Your Barbas dealer 001 21 08 2018 347116...

Отзывы: