• The fireplace must have ventilation openings near the bottom and near the top of the
fireplace.
• The total ventilation air inlet openings must have an area of at least 450 cm
2
. (For
example 2 inlet openings with an area of at least 225 cm
2
each.)
• The total ventilation air outlet openings must have an area of at least 450 cm
2
. (For
example 2 outlet openings with an area of at least 225 cm
2
each.)
66.1.3
Requirements on the chimney
• Make sure that in case of use of an existing (masonry) chimney, it is in good order and
applicable for the appliance. Ask your dealer or chimney sweeper for advice.
• Make sure the flue system obeys the national and local applicable regulations.
• Do not connect more than one appliance to the same chimney.
• The flue system must have a temperature class designation of at least T400.
• The inner diameter of the existing chimney must be at least 200 mm.
• Do not use more than 2 bends of 45°.
• The chimney outlet must be at least 5 meter above the top of the appliance.
• The chimney outlet must be at least 40 cm above the top of a sloped roof.
• The chimney outlet must be at least 1 meter above a flat roof.
• The chimney outlet must be free from any objects (buildings, trees, etc.) within a
horizontal range of at least 5 meter.
• Make sure your fire insurance policy covers any damage caused by a chimney fire.
6.2
Preparation for installation
• If applicable, make sure a 230 VAC grounded electrical connection is located near the
installation location.
Warning:
• The electrical connection must be grounded.
• The electrical connection must be made by a certified electrician.
• Make sure the electrical connection can always be accessed.
• Make sure the door of the appliance opens and closes correctly.
• Make sure the baffle is in the correct position
• Make sure the control lever can move freely to left and to right.
• Make sure the ashtray is empty.
6.3
Installation procedure
Do all the procedures in this section. Optional procedures are indicated with (optional).
Installation
Falcon 66/56
17
Содержание Falcon 66/56
Страница 28: ...Annual maintenance 2 28 Falcon 66 56...
Страница 31: ...9 9 Dimensions 9 1 Frameless appliance Dimensions Falcon 66 56 31...
Страница 33: ...9 9 3 Appliance with 3 sided classic frame Dimensions Falcon 66 56 33...
Страница 34: ...9 9 4 Appliance with 4 sided classic frame Dimensions 34 Falcon 66 56...
Страница 37: ...Warranty Terms Falcon 66 56 3 37...
Страница 38: ...Warranty Terms 3 38 Falcon 66 56...
Страница 39: ...Warranty Terms Falcon 66 56 3 39...
Страница 40: ...Y Your Barbas dealer 001 21 08 2018 347116...