66.3.5
Connect the convection set (optional)
Connect the aluminum pipe to the appliance
1. On the convection air box select one
of the 2 inlet openings, identified by
"FAN", on the left or right side.
a) Remove one (1) break out plate
in the selected convection air
inlet opening with a hammer.
b) Put the collar adaptor in the open inlet opening.
c) Bend out the 3 lips on the collar adaptor, to attach the collar adaptor on the inlet
opening
d) Connect a flexible aluminum pipe (B) on the collar adaptor (A). Use a hose
clamp
©
).
2. Connect the flexible aluminum pipe to a fitting box in the chimney breast
3. On the appliance, remove the two
break out plates in the convection air
outlet openings with a hammer.
4. Put the collar adaptors in the open
outlet openings.
5. Bend out the 3 lips on each collar
adaptor, to attach the collar adaptor on the outlet opening.
6. Connect the flexible aluminum pipes
(B) on the collar adaptors (A) . Use
the hose clamps
©
).
7. Connect the flexible aluminum pipes
to fitting boxes in the chimney
breast.
Installation
Falcon 66/56
21