min. 50cm
min. 20cm
• The fireplace must have ventilation openings near the bottom and near the top of the
fireplace to avoid heat accumulation in the fireplace.
• The total ventilation air inlet openings must have an area of at least 450 cm
2
. (For
example 2 inlet openings with an area of at least 225 cm
2
each.)
• The total ventilation air outlet openings must have an area of at least 450 cm
2
. (For
example 2 outlet openings with an area of at least 225 cm
2
each.)
6.3
Requirements on the chimney
• Make sure that in case of use of an existing (masonry) chimney, it is in good order and
applicable for the appliance. Ask your dealer or chimney sweeper for advice.
• Install a stainless steel pipe (flexible or rigid) chimney in any new or existing masonry
chimney.
• Make sure to insulate the stainless steel chimney or use double-walled insulated
stainless steel chimney elements.
• Make sure the flue system obeys the national and local applicable regulations.
• Do not connect more than one appliance to the same chimney.
• The flue system must have a temperature class designation of at least T400.
• Do not use more than 2 bends of 45°.
• The chimney outlet must be at least 5 meter above the top of the appliance.
• The chimney outlet must be at least 40 cm above the top of a sloped roof.
• The chimney outlet must be at least 1 meter above a flat roof.
• The chimney outlet must be free from any objects (buildings, trees, etc.) within a
horizontal range of at least 5 meter.
• Make sure your fire insurance policy covers any damage caused by a chimney fire.
Installation requirements
28
Cuatro-7 75-60
Содержание Cuatro-7 75-60
Страница 6: ...1 Declaration of performance Declaration of performance 6 Cuatro 7 75 60...
Страница 56: ...11 2 Connections on Opti Air system Technical data 56 Cuatro 7 75 60...
Страница 59: ...12 Dimensions 12 1 Cuatro 7 75 60 with built in frame Dimensions Cuatro 7 75 60 59...
Страница 60: ...12 2 Cuatro 7 75 60 with built in frame and convection casing Dimensions 60 Cuatro 7 75 60...
Страница 66: ...12 8 Cuatro 7 75 60 with classic frame Dimensions 66 Cuatro 7 75 60...
Страница 67: ...12 9 Cuatro 7 75 60 with classic frame and convection casing Dimensions Cuatro 7 75 60 67...
Страница 75: ...Warranty Terms Cuatro 7 75 60 75...
Страница 76: ...Your Barbas dealer 001 28 06 2022 352574 271 001...