8.7.2
Connection on the combustion air box
1.
Identify the location in the outer wall or in the floor (to a ventilated crawl space) for
the external combustion air supply inlet.
2.
Make a hole in the outer wall or floor with a diameter of minimum 125 mm.
3.
Install a grate in the hole in the outer wall. A grate is not needed when the
combustion air supply comes from the crawl space under the floor.
Note:
The image shows the combined convection ventilator / combustion
air inlet box.
4.
If applicable, select one of the 3 inlet
openings on the left, right or bottom
of the optional combustion air inlet
box or the convection ventilator /
combustion air inlet box .
5.
Remove the break out plate in the
selected inlet opening of the optional
convection air/ combustion air inlet
box with a hammer.
6.
Put the collar adaptor in the open
inlet opening (1).
7.
Bend out the 3 lips on the collar
adaptor (2) and turn the adapter until
it locks.
8.
Connect a flexible aluminum pipe
©
)
with a diameter of 125 mm on the
collar adaptor. Use a hose clamp (B).
9.
Connect the other end of the flexible
aluminum pipe with the hole in the
floor or the grate in the wall. Use a
suitable connector.
2
2
1
A
B
C
Installation in a new fireplace
Cuatro-7 75-60
35
Содержание Cuatro-7 75-60
Страница 6: ...1 Declaration of performance Declaration of performance 6 Cuatro 7 75 60...
Страница 56: ...11 2 Connections on Opti Air system Technical data 56 Cuatro 7 75 60...
Страница 59: ...12 Dimensions 12 1 Cuatro 7 75 60 with built in frame Dimensions Cuatro 7 75 60 59...
Страница 60: ...12 2 Cuatro 7 75 60 with built in frame and convection casing Dimensions 60 Cuatro 7 75 60...
Страница 66: ...12 8 Cuatro 7 75 60 with classic frame Dimensions 66 Cuatro 7 75 60...
Страница 67: ...12 9 Cuatro 7 75 60 with classic frame and convection casing Dimensions Cuatro 7 75 60 67...
Страница 75: ...Warranty Terms Cuatro 7 75 60 75...
Страница 76: ...Your Barbas dealer 001 28 06 2022 352574 271 001...