USING THE APPLIANCE FOR THE FIRST TIME

The gas fire is coated with a lacquer layer resistant to high temperature. During
the first hours of operation, the burning in of the lacquer may result in an
unpleasant smell. This is harmless, however. Operating the gas fire at full capacity
for a few hours, while ventilating the room, will eliminate the smell. Moreover,
deposits may form on the inside off the glass; these can be removed with a dry
cloth when the gas fire has cooled down.

1.8

DAILY MAINTENANCE

l

Regulary check that the air supply is still open.

l

Ensure that as little dust, and as few particles of cigarette smoke, candles
and oil lamps as possible pollute the air in the room in which the appliance is
used. Heating of these particles by the convection system of the appliance
could lead to discoloration of the walls and ceiling. It is therefore very
important to ensure that the room in which the appliance is located is
sufficiently ventilated. Regularly remove any dust deposits from behind the
control flap by means of a vacuum cleaner.

If the glass is broken or cracked, it must be
immediately replaced before operating the
gas fire again.

l

If anything is spilt on the fire, switch it off immediately and wait for it to cool
down sufficiently before cleaning. Never use scouring powder, aggressive
cleaners or fire polish on the gas fire. Use only a dry lint free cloth.

l

Barbas heat resistant lacquer in aerosols can be obtained from your
distributor. During the yearly maintenance, the lacquer can be used to repair
small areas of damage.

Stains on soap stone can be removed by rubbing gently with a washing-up
sponge and drying with a tea towel.

IMPORTANT

The installation must only be carried out by a

CORGI registered installation engineer.

Содержание ATLANTA

Страница 1: ...Ireland ECO 550 ECO 650 ECO 750 NG ECO 550 ECO 650 ECO 750 PG Italia ATLANTA SAVANNAH NI ATLANTA SAVANNAH PI ECO 550 ECO 650 ECO 750 NI ECO 550 ECO 650 ECO 750 PI Espa a ATLANTA SAVANNAH NE ATLANTA S...

Страница 2: ...50 ECO 750 CONTENTS 1 INSTRUCTIONS FOR USE 2 INSTALLATION INSTRUCTIONS 3 MAINTENANCE 4 FAULTS 5 DISASSEMBLY ASSEMBLY OF THE REGULATOR AND BURNER 6 DIMENSIONS 7 TECHNICAL DETAILS REGULATIONS 8 REPLACEM...

Страница 3: ...4 ECO 550 ECO 650 ECO 750 SAVANNAH A TLANTA...

Страница 4: ...t light shut off in the event of a gas escape from the main burner Additionally the gas fire is fitted with a thermal one way protection safety system This system shuts off the appliance if the flue g...

Страница 5: ...has one main burner which can be operated by the thermostatic knob and or the sliding knob The thermostatic knob is used to choose the correct setting and the modulating thermostat ensures that the s...

Страница 6: ...the thermostat knob to the required setting and or pushing the slider into an downward position the burner will now ignite 1 5 TURNING OFF THE FIRE l Turn the thermostat knob to the ignition position...

Страница 7: ...ection system of the appliance could lead to discoloration of the walls and ceiling It is therefore very important to ensure that the room in which the appliance is located is sufficiently ventilated...

Страница 8: ...20 Pa 0 2 mbar then it is recommended to reduce it IMPORTANT Before beginning the installation check that the details on the rating plate correspond to the gas type and pressure to which the appliance...

Страница 9: ...g to the regulations 1 NATURALLY VENTILATED HOUSE see Figure 2 The room in which the appliance is to be fitted must have a non closable combustion air supply opening The minimum dimensions are detaile...

Страница 10: ...fitted must have a non closable combustion air supply opening The minimum dimensions are detailed in Technical Details Regulations at the rear of this manual see also Paragraph 2 4 point 2 The flue g...

Страница 11: ...ntering 2 COMBUSTIONAIR SUPPLY The combustion air supply has to comply with national and local regulations The minimum dimensions are detailed in Technical Details Regulations at the rear of this manu...

Страница 12: ...uch as curtains should not be placed in the vicinity of the gas fire Minimum safe distance 100 cm 2 5 1 Chimney connection opening The appliance has a combined chimney top rear connection opening whic...

Страница 13: ...the side stones by gently sliding them downwards over the rail If necessary the rail can be adjusted Position the top stone with the round hole with the widest part facing upwards If you are using th...

Страница 14: ...gas tight using soapy water or a leak tester 2 5 6 Positioning the Ceramic Log Set IMPORTANT Do not place any vermiculite or logs against the pilot flame burner Make sure that the pilot flame can burn...

Страница 15: ...ould gradually increase in height and become more yellow When all flames are yellow the gas fire has reached the correct temperature The installer should also verify by using the appliance for the fir...

Страница 16: ...peration of the gas regulating block thermocouple circuit and the ignition of the main burner l Checking the operation of the security system 4 FAULTS Possible reasons for the gas fire going out are O...

Страница 17: ...ove the glass plate Caution The edges of the glass plate may be sharp WEAR GLOVES ECO 750 Remove the front by loosen the allens at the bottomside under the controlpanel and the upperside in the corner...

Страница 18: ...19 ENGLISH A TLANTA SAVANNAH ECO 550 ECO 650 ECO 750 Figure 7 ATLANTA SAVANNAH ECO 550...

Страница 19: ...TLANTA Figure 8 ECO 650 ECO 750 5 2 ASSEMBLY Assemble in the reverse order Ensure that the bottom plate sealing cord and the glass plate mate correctly Re check all re fitted gas connections for leak...

Страница 20: ...21 ENGLISH A TLANTA SAVANNAH ECO 550 ECO 650 ECO 750 Gas connection 6 DIMENSIONS 6 1 ATLANTA SAVANNAH...

Страница 21: ...22 ECO 550 ECO 650 ECO 750 SAVANNAH A TLANTA Gas connection 6 2 ECO 550...

Страница 22: ...23 ENGLISH A TLANTA SAVANNAH ECO 550 ECO 650 ECO 750 Gas connection 6 3 ECO 650...

Страница 23: ...24 ECO 550 ECO 650 ECO 750 SAVANNAH A TLANTA Gas connection 6 4 ECO 750...

Страница 24: ...t nett calorific value 10 3 kW 9 5 kW Nominal heat output max 5 8 6 7 kW 5 2 6 2 kW Gas rate max 1 09 m3 s hr 730 gr hr Supply pressure 20 0 mbar 37 0 mbar Burner pressure max Hot 9 3 mbar 29 0 mbar B...

Страница 25: ...59 Pilot light set outer casing SIT 0 160 022 11 301207 Pilot light pipe 4 mm l 230 mm 12 301976 Pilot light olive 4 mm 13 301977 Pilot light nut 4 mm 14 302069 Pilot light electrode cable l 250 mm 15...

Страница 26: ...o Part no Description 31 301516 Glass clamp model T 32 301509 Glass clamp model L 33 301526 Glass clamp model W 34 301669 Tube ceramic glue 35 301846 Log set Natural gas 36 301848 Log set Propane 37 3...

Страница 27: ...01 151205 303376 INTERFOCOS B V HALLENSTRAAT 17 5531 AB BLADEL NEDERLAND E mail info barbas nl Internet www barbas com...