thrum
31102
The hook thread action
time with clamp function
without any thrum
0-990
30
31103
The return back time of
hook thread with clamp
function without any
thrum
0-990
30
31104
Duty cycle for hook
thread with clamp
function without any
thrum
0-100
0
31105
The suction time for
clamp function without
any thrum
0-5000
1000
31106
Duty cycle for pull thread
with clamp function
without any thrum
0-100
80
3.12 Layer seam setting
No.
Items
Range
Default
Description
31201
Layer seam mode rotation
speed over thick
200-3700
2000
31202
Fabric thickness sensor
AD value
0-1023
530
31203
Layer seam proportion
1-100
10
31204
Layer seam stitch length
limit
0-5.0
4.0
3.13 Other setting
No.
Items
Range
Default
Description
Parameter
31301
Type selection
1-50
37
P70
4 Error Code List
Error Code
Problem
Measure
E01
Over-voltage
Turn off the system power and check whether the power supply voltage is
correct. (Or whether it exceeds the specified rated voltage).
E02
Low-voltage
Turn off the system power and check whether the power supply voltage is
correct. (
Or
whether it is lower than the specified rated voltage).
E03
Abnormal communication between
the main CPU and the driver CPU
Turn off the power and check whether the connector is connected to the
operation panel and the cable condition.
E05
Speed control unit connection is
abnormal
Please turn off the power and check whether the connector is connected to the
speed controller and the cable condition.
13