3.6 Safety protection setting
No.
Items
Range
Default
Description
3601
Machine protection switch
testing
0-2
1
0: Disable
1: Testing zero signal
2: Testing positive signal
3602
Oil level lower protection
testing
OFF/ON
OFF
3603
Setting high voltage
protection value
850-1023
880
When the external input AC voltage is converted into
DC voltage and the value exceeds the set value, the
system will alarm E01 and stop working.
3604
Tension electromagnet
protection time
1-60
2
Electromagnet working protection time (S)
3605
Trimming protection
switch
OFF/ON
OFF
3.7 Stitch length setting of stepping back-tacking
No.
Items
Range
Default
Description
3701
Back-tacking motor
zero-point correction
-100
~
100
50
3702
Normal stitch length
0-5.0
3.0
3703
Stitch length reference value
setting
3704
Tacking stitch length
compensation
0-100
50
3705
Back-tacking stitch length
compensation
0-100
58
3706
Back-tacking stitch
compensation
0-200
167
3707
Back-tacking step motor
steady current
1-12
6
3708
Back-tacking step motor
maximum current
1-12
12
3709
Manual close stitches distance
0-5.0
2.0
3710
Correction stitches distance of
manual button A
0-5.0
3.0
3711
Correction stitches distance of
manual button B
0-5.0
3.0
3712
Correction stitches distance of
manual button C
0-5.0
3.0
3713
Correction stitches distance of
manual button D
0-5.0
3.0
3714
Maximum stitch length limit
0-8.0
5.0
3.7.3 Stitch length adjustment
Forward
Stitch length
Backward
Stitch length
1mm
1mm
2mm
2mm
3mm
3mm
4mm
4mm
5mm
5mm
6mm
6mm
7mm
7mm
8mm
8mm
10