39102
Control box vice version
number
39103
Display board version
number
39104
Step drive version number
3.10 Main shaft motor setting
No.
Items
Range
Default
Description
31001
Main shaft motor maximum
speed limit
0-5000
3700
31002
Main shaft motor zero-point
correction
31003
Up position quick
adjustment
31004
Down position quick
adjustment
31005
Speed limit of manual
back-tacking
0-3200
0
31006
Reverse angle function
selection after trimming
ON/OFF
OFF
31007
Adjustment of reverse angle
after trimming
10-50
40
31008
Up position value
0-359
100
31009
Down position value
0-359
275
31010
Low (positioning) speed
100-500
210
31011
Stopping strength as
half-way
1-45
16
31012
Stopping strength after
trimming
1-50
20
31013
Up / down needle position
distance value
15-359
175
In the quick setting interface of the needle
position for the upper and lower stops, when
the upper positioning value is saved, the lower
positioning value will be automatically
calculated based on the upper and lower
positioning distance values.
31014
Main shaft motor rotation
direct setting
CCW/CW
CCW
CW: Clockwise
CCW: Counterclockwise
31015
Main shaft motor maximum
current (A)
0-20
10
31016
Main shaft motor
lockedrotor current (A)
0-20
10
31017
Main shaft motor normal
current (A)
0-20
16
31018
Main shaft motor encoder
type selection
No magnetic
ring / With
magnetic ring
No magnetic
ring
3.11 Clamp function without any thrum
No.
Items
Range
Default
Description
31101
The delay time before
hook thread with clamp
function without any
0-990
100
12