5.1.2 The lower tube clamp position will move downward when two sides of 
rubbing wheel rotates in a counterclockwise direction as below:   

 

5.1.3 Low tube clamp position for different size tubing instruction:   
 
(1)

 

When the lower tube clamp is at the top, it can fit for:   

  1.6mm wall thickness tubing: 13#, 14#, 19#, 16#, 25#.   

  Note: It is suitable both for single and dual channel. 

 

 

The lower tube clamp display 
white and blue color.   

Содержание EasyPump I

Страница 1: ...Shenchen Precision Pump Manual of EasyPump Series Baoding Shenchen Precision Pump Co Ltd...

Страница 2: ...the tubing carefully each time to see if it is damaged Move the tubing working position after it was used for a period of time in order to extend the tube lifetime Please loosen the tube when not in u...

Страница 3: ...troduction 1 2 Product Instruction 2 3 EasyPump Head Dimension 12 4 EasyPump Series Specification and Flow Rate Chart 14 5 Function Instruction 16 6 Troubleshooting 20 7 Maintenance 21 8 Warranty and...

Страница 4: ...clamp automatically resets and fixes the tube At the same time the Trigger lever assist mechanism assists the user in pressing the upper pressure block The rubbing wheel mechanism can adjust the posi...

Страница 5: ...gle Fixed EasyPump II 2 4mm 15 24 35 36 Single Fixed EasyPump III 1 6mm 13 14 19 16 25 17 18 Single Adjustable EasyPump IV 2 4mm 15 24 35 36 Single Adjustable EasyPump V 1 6mm 13 14 19 16 25 Dual Fixe...

Страница 6: ...essure block Upper tube clamp Lower support Body base Roller assembly Lower tube clamp Rubbing wheel Single channel adjustable tube pressure gap pump head Body base Upper pressure block Lever Roller a...

Страница 7: ...Standard flat shaft pump head installation with rubber coupler First install the rubber coupler on the pump head shaft the narrow groove of the rubber coupler is butt connected with the boss of the m...

Страница 8: ...install the pump head on the driver motor shaft with coupler fasten the pump head screws to fix the pump head on the driver Please try to use same force to fasten the screws Pump head screw Plum blos...

Страница 9: ...atus as in below picture when you receive it Remove the two M4 nuts install the complete pump head group pump head 1 2 3 to the pump drive then adjust the height of the multiple pump head support acco...

Страница 10: ...ft connection between two adjacent pump heads needs to install shock absorber as in below picture otherwise it will cause the pump head to work abnormally Except that the outermost pump head has a low...

Страница 11: ...to open the upper pressure block then use a flat blade screwdriver to insert into the buckle position as shown in below picture pry open the buckle position with a slight force and then remove the low...

Страница 12: ...g Installation Pull the lever 180 counterclockwise and open the upper pressure block Put the tubing between rollers and upper pressure block Pull the lever 180 clockwise and push upper pressure block...

Страница 13: ...tube deviates to scratch itself in a running process as below Please pay special attention to straighten the tube in the natural direction It should not be twisted and pressed on the slider otherwise...

Страница 14: ...led it does not set aside enough length and space to cause the tubing inside the pump head work part deviation tubing will be cut as below Note If must use the tubing as in above status please contact...

Страница 15: ...Shenchen Pump EasyPump Series 12 3 EasyPump Head Dimension 3 1 Fixed tube pressure gap EasyPump Standard shaft 3 2 Adjustable tube pressure gap EasyPump Standard shaft...

Страница 16: ...Shenchen Pump EasyPump Series 13 3 3 Fixed tube pressure gap EasyPump Compact shaft 3 4 Fixed tube pressure gap Round shaft...

Страница 17: ...2580 0 1 0 07 Single channel EasyPump 15 4 8 2 4 1 8 0 180 1080 0 27 0 17 24 6 4 2 4 2 733 0 273 1640 35 7 9 2 4 3 833 0 383 2300 0 24 0 14 36 9 6 2 4 5 167 0 517 3100 Dual channel EasyPump 13 0 8 1...

Страница 18: ...Shenchen Pump EasyPump Series 15 4 2 Flow Rate Chart Tube WT 1 6mm Single channel Tube WT 1 6mm Dual channel Tube WT 2 4mm Single channel...

Страница 19: ...the rubbing wheel to adjust the position of the lower tube clamp position to make the pump head fit for different size tubing Note Please adjust the lower tube clamp position first before install tubi...

Страница 20: ...rotates in a counterclockwise direction as below 5 1 3 Low tube clamp position for different size tubing instruction 1 When the lower tube clamp is at the top it can fit for 1 6mm wall thickness tubin...

Страница 21: ...4mm wall thickness tubing size 15 24 Just for single channel 3 When the lower tube clamp is at the bottom position it can be fit for 2 4mm wall thickness tubing size 35 36 Note The above lower tube cl...

Страница 22: ...the adjustment range can be used normally A total of 5 scale values are set as indicators in the adjustment range Scale 3 is the factory standard scale value which can be used as the initial position...

Страница 23: ...ler the scale value the smaller the output pressure of the pump head tube and the lighter the tube is compressed The pump head is more prone to no liquid or output liquid dropping during use Therefore...

Страница 24: ...dry otherwise it can quicken the tubing wearing reduce the useful life of tubing and lead the rollers to damage in earlier The pump head is not resistant to super corrosive liquids please be attentio...

Страница 25: ...hich may arise in connection with a warranty claim If the pump fails during the warranty period after confirmation by our technical department we will provide spare parts free of charge Customers will...