background image

10 Banner Engineering Corp. Limited Warranty

Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will

repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This

warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY

WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING

OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE

LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR

SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR

WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product

previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection

applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval

by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product

specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most

recent version of any documentation, refer to: 

www.bannerengineering.com

.

For patent information, see 

www.bannerengineering.com/patents

.

WORLD-BEAM QS18 Expert with IO-Link

 

 

30

www.bannerengineering.com - Tel: + 1 888 373 6767

 

Содержание WORLD-BEAM QS18 Expert Series

Страница 1: ...WORLD BEAM QS18 Expert with IO Link Instruction Manual Original Instructions 196872 Rev B 19 September 2019 Banner Engineering Corp All rights reserved 196872...

Страница 2: ...2 4 Select TEACH SET Method 14 5 Configure TEACH SET 15 6 TEACH SET 17 7 Specifications 19 7 1 Self Contained Models Specifications 19 7 2 Opposed Mode Models Specifications 20 7 3 Dimensions 21 7 4 S...

Страница 3: ...very dark objects Health data available over IO Link Auto compensation algorithm provides long and reliable operation by compensating for dust build up and ambient temperature changes Fast response sp...

Страница 4: ...i function input output QS18EK6EQ8 Infrared 940 nm OPPOSED IO Link and multi function input QS18EK6RQ8 IO Link push pull output and multi function input output 4 Pin M12 Euro style integral quick disc...

Страница 5: ...er Flashing ON OFF Notification Push button has been locked out Flashes four times and returns to solid On after button press ON OFF Opposed Mode Emitter Indicators Sensor Condition Green LED Amber LE...

Страница 6: ...ut Factory Default 4 1 3 2 10 30V dc CH1 CH2 PUSH PULL Load Load Figure 1 Channel 1 IO Link Channel 2 PNP Output IO Link with PNP Remote Input 4 1 3 2 10 30V dc CH1 CH2 PUSH PULL Load Remote Input Fig...

Страница 7: ...PNP Output and Remote Input 4 1 3 2 10 30V dc CH1 CH2 Load Remote Input Figure 6 Channel 1 PNP Output Channel 2 PNP Remote Input 1 4 3 2 Figure 7 Sensor Pinout M12 Euro style Models Male 3 2 1 4 Figu...

Страница 8: ...cedures and is enabled upon return to Run mode See the Input Flowcharts for configuration information Self contained models Figure 9 p 9 Opposed mode emitters Figure 10 p 10 Opposed mode receivers Fig...

Страница 9: ...ry defaults flashing both Green and Amber LEDs 8X followed by acceptance flash 8x Push Button or Remote Input Wire Configuration using remote input wire when enabled through IO Link 1x Second Pulse Co...

Страница 10: ...ITTER Remote Input Wire Configuration using remote input wire when enabled through IO Link High Speed flashing of both Green and Amber LEDs 1X followed by acceptance flash Configure to A Frequency fla...

Страница 11: ...Amber LEDs 5X followed by acceptance flash Select Two Point Static TEACH flashing of both Green and Amber LEDs 1X followed by acceptance flash Select Dynamic TEACH flashing of both Green and Amber LED...

Страница 12: ...Device AOIs as desired linking them to the Master AOI as shown in the relevant AOI documentation Banner has also developed Function Blocks to simplify ease of use between the QS18E multiple third par...

Страница 13: ...sh Remote From Run mode pulse the remote three time then pulse two times to disable the button Push Button Enable Push Button From Run mode click the button three times then click one time to enable t...

Страница 14: ...Click the button one time The selected TEACH SET method is enabled Dynamic TEACH Click the button two times Window SET Click the button three times Light SET Click the button four times Dark SET Click...

Страница 15: ...the ON and OFF conditions 3 Click the Push Button once to stop the Dynamic TEACH process and return to Run mode Window SET 1 Present the target condition 2 Press and hold the button for greater than 2...

Страница 16: ...ED indicators flash six times rapidly in unison acceptance flash 3 The sensor returns to Run mode with valid thresholds Invalid Teach Condition 1 The green and amber indicator LEDs flash two times in...

Страница 17: ...ed Models Output ON and OFF conditions may be reversed by switching the TEACH order or by changing the Light Dark Operate setting Dynamic TEACH is recommended for applications where a machine or proce...

Страница 18: ...Self contained models 30 default Opposed mode models 50 default Any condition lighter than the threshold causes the output to change state In Light Operate mode the presented condition is the Output O...

Страница 19: ...and FP Models Two point Static TEACH LP Models Light SET Output Logic D DV CV and FP Models Light Operate LP Models Dark Operate Output Response Time Standard Offset Percentage 30 Push Button Unlocked...

Страница 20: ...igh Speed Auto 350 212 A B C Fixed 1000 400 A B C Auto 1100 600 Emitter Power High Power is Power 5 Low Power is Power 0 The following power levels are available via IO Link to set intermediate power...

Страница 21: ...rrent Protection Amps 20 5 0 22 3 0 24 2 0 26 1 0 28 0 8 30 0 5 Construction Housing ABS Window PMMA Mounting Torque Nose Mount 18 mm mounting nut 20 Ibf in 2 3 N m Side Mount Two M3 screws 5 Ibf in 0...

Страница 22: ...f Contained Models Performance Curves Performance using Dark SET performed in no light condition Polarized Retroreflective Excess Gain Beam Pattern Diffuse Based on use of 90 reflectance white test ca...

Страница 23: ...Diffuse Based on use of 90 reflectance white test card Excess Gain Beam Pattern Convergent Excess Gain Beam Pattern WORLD BEAM QS18 Expert with IO Link www bannerengineering com Tel 1 888 373 6767 23...

Страница 24: ...Convergent Excess Gain Beam Pattern Fiber Optic Plastic Excess Gain Beam Pattern WORLD BEAM QS18 Expert with IO Link 24 www bannerengineering com Tel 1 888 373 6767...

Страница 25: ...20 24 1000 800 600 400 200 0 200 400 600 800 1000 High Power Mode Low Power Mode Infrared QS18EK6E QS18EK6R Excess Gain Curve Beam Pattern 1 10 100 1000 10000 DISTANCE mm EXCESS GAIN 0 1 1 10 100 Hig...

Страница 26: ...2 Typ 1 26 30 Typ 1 18 14 5 0 57 M12 x 1 MQDC 415RA 4 57 m 15 ft MQDC 430RA 9 14 m 30 ft MQDC 450RA 15 2 m 50 ft 4 Pin Threaded M8 Pico Style Cordsets Single Ended Model Length Style Dimensions Pinout...

Страница 27: ...ustment Easy sensor mounting to extruded rail T slots Metric and inch size bolts available Side mounting of some sensors with the 3 mm screws included with the sensor 40 43 A B B 7 M3 0 5 Model Bolt T...

Страница 28: ...ture 20 C to 60 C 4 F to 140 F Optional brackets are available Approximate size 92 mm 92 mm BRT 40X19A Rectangular acrylic target Reflectivity Factor 1 3 Temperature 20 C to 60 C 4 F to 140 F Approxim...

Страница 29: ...is located at 9714 Tenth Avenue North Minneapolis MN 55441 USA Phone 1 888 373 6767 For worldwide locations and local representatives visit www bannerengineering com WORLD BEAM QS18 Expert with IO Lin...

Страница 30: ...ENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT WHETHER ARISING IN CONTRACT OR WARRANTY STATUTE TORT STRICT LIABILITY NEGLIGENCE OR OTHERWIS...

Отзывы: