background image

Wiring

shield (QD cordset)

3

1

2

4

5

12-30V dc

Load 1

Load 2

+

Wiring Key:

1. Brown
2. White
3. Blue
4. Black
5. Gray (Do not connect)

NOTE: Banner recommends that the shield wire

(QD cordsets only) be connected to earth ground

or dc common. Shielded cordsets are

recommended for all QD models.

Accessories

Quick Disconnect (QD) Cordsets

5-Pin Threaded M12/Euro-Style Cordsets—with Shield

Model

Length

Style

Dimensions

Pinout (Female)

MQDEC2-506

1.83 m (6 ft)

Straight

44 Typ.

ø 14.5

M12 x 1

2

3

4

1

5

1 = Brown

2 = White

3 = Blue

4 = Black

5 = Gray

MQDEC2-515

4.57 m (15 ft)

MQDEC2-530

9.14 m (30 ft)

MQDEC2-550

15.2 m (50 ft)

MQDEC2-506RA

1.83 m (6 ft)

Right-Angle

32 Typ.

[1.26"]

30 Typ.

[1.18"]

ø 14.5 [0.57"]

M12 x 1

MQDEC2-515RA

4.57 m (15 ft)

MQDEC2-530RA

9.14 m (30 ft)

MQDEC2-550RA

15.2 m (50 ft)

NOTE: Pin 5 is not used.

Brackets and Other Accessories

SMBQ240SS2

Add-on accessory to be

used in conjunction with

SMBQ240SS1

Provides ± 20° of tilt in

second axis for maximum

control of sensor alignment

12 gauge stainless steel

Q240WS

Coated to help repel water

and maximize signal

strength

Snap-on cover for easy

application and replacement

 

 

R-GAGE

 Q240RA-AF2 Sensor

8

www.bannerengineering.com - Tel: +1-763-544-3164

P/N 184564 Rev. A

Содержание R-GAGE Q240RA-AF2

Страница 1: ...ct Contact Banner Engineering for more information WARNING Not To Be Used for Personnel Protection Never use this device as a sensing device for personnel protection Doing so could lead to serious injury or death This device does not include the self checking redundant circuitry necessary to allow its use in personnel safety applications A sensor failure or malfunction can cause either an energize...

Страница 2: ... 3 5 m 11 5 ft Y Maximum Zone 1 setpoint distance 30 m 98 4 ft 30 m 98 4 ft A Minimum Zone 2 offset from Zone 1 2 m to 25 m 4 m 13 1 ft 5 5 m 18 0 ft B Maximum Zone 2 offset from Zone 1 2 m to 25 m 55 m 180 4 ft 55 m 180 4 ft D Dead Zone1 Sensor Configuration Use the included spanner to open the screw off cover on the side of the sensor and access the DIP switches Important Tighten the DIP switch ...

Страница 3: ...4 Distance CN US 0 0 0 0 2 m 6 6 ft 3 5 m 11 5 ft 0 0 0 1 2 5 m 8 2 ft 4 m 13 1 ft 0 0 1 0 3 m 9 8 ft 4 5 m 14 8 ft 0 0 1 1 3 5 m 11 5 ft 5 m 16 4 ft 0 1 0 0 4 m 13 1 ft 5 5 m 18 0 ft 0 1 0 1 5 m 16 4 ft 6 m 19 7 ft 0 1 1 0 6 m 19 7 ft 6 5 m 21 3 ft 0 1 1 1 7 m 23 0 ft 7 m 23 0 ft 1 0 0 0 8 m 26 2 ft 8 m 26 2 ft 1 0 0 1 10 m 32 8 ft 10 m 32 8 ft 1 0 1 0 12 m 39 4 ft 12 m 39 4 ft 1 0 1 1 14 m 45 9 ...

Страница 4: ...3 Sensitivity 0 0 0 8 Highest 0 0 1 7 0 1 0 6 High 0 1 1 5 1 0 0 4 Medium 1 0 1 3 1 1 0 2 Low 1 1 1 1 Lowest Default settings NOTE Operation at a high sensitivity not guaranteed for a zone set beyond 45 m 147 6 ft Output Configuration A8 NPN PNP 0 NPN 1 PNP Default settings B7 Normally Open Closed 0 NO 1 NC Response Speed B4 B5 B6 ON Total ms OFF Total ms Total ms 0 0 0 15 15 30 0 0 1 30 70 100 0 ...

Страница 5: ...d configuration See Overview on page 1 Adjustments DIP switch configurable sensing distance sensitivity response time and output configuration Construction Housing Polycarbonate Lightpipes Acrylic Access Cap Polyester Operating Temperature 40 to 65 C 40 to 149 F Environmental Rating IP67 Connections Integral M12 Euro style QD fitting QD models require a mating cordset Certifications CMIIT Category...

Страница 6: ...ar Large Truck Passenger Train 4 3 2 1 At sensitivity level 8 1 Weak Object Radar cross section 0 25 m2 2 Car Radar cross section 3 m2 3 Large Truck Radar cross section 50 m2 4 Passenger Train Radar cross section 300 m2 0 0 1 2 3 4 5 6 4 3 6 5 2 1 5 10 15 20 25 Meters 30 35 40 45 Meters Car Large Truck Passenger Train 4 3 2 Weak Object Trace Data 1 At sensitivity level 4 NOTE The effective beam pa...

Страница 7: ...repeat every 6 1 mm of distance between the sensor and the window The positions of maximum reflection from the window repeat between the minimums and decrease in effect until the window is approximately 150 mm 5 9 in away Consult the factory for pre tested window materials which can be used at any distance without issue Additionally the face of the window should be protected from flowing water and...

Страница 8: ...2 White 3 Blue 4 Black 5 Gray MQDEC2 515 4 57 m 15 ft MQDEC2 530 9 14 m 30 ft MQDEC2 550 15 2 m 50 ft MQDEC2 506RA 1 83 m 6 ft Right Angle 32 Typ 1 26 30 Typ 1 18 ø 14 5 0 57 M12 x 1 MQDEC2 515RA 4 57 m 15 ft MQDEC2 530RA 9 14 m 30 ft MQDEC2 550RA 15 2 m 50 ft NOTE Pin 5 is not used Brackets and Other Accessories SMBQ240SS2 Add on accessory to be used in conjunction with SMBQ240SS1 Provides 20 of ...

Страница 9: ... AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND WHETHER ARISING UNDER COURSE OF PERFORMANCE COURSE OF DEALING OR TRADE USAGE This Warranty is exclusive and limited to repair or at the discretion of Banner Engineering Corp replacement IN NO EVENT SHALL BANNER ENGINEERING CORP BE LIAB...

Отзывы: