B6

ON Total (ms)

OFF Total (ms)

Total (ms)

1

0

0

50

600

650

1

0

1

30

1000

1030

1

1

0

120

600

720

1

1

1

120

6000

6120

* Default settings

Specifications

Range

The sensor is able to detect a proper object (see Detectable Objects)

from 1 to 40+ m (3.3 to 131.2+ ft), depending on target

Detectable Objects

Objects containing metal, water, or similar high-dielectric materials

Operating Principle

Frequency modulated continuous-wave (FMCW) radar

Operating Frequency

24.00 to 24.25 GHz, ISM Band (varies slightly with model, depending

on national telecom regulations)

Supply Voltage

12 to 30 V dc, less than 100 mA, exclusive of load

Supply Protection Circuitry

Protected against reverse polarity and transient overvoltages

Delay at Power-up

Less than 2 seconds

Output Configuration

DIP switch A8 selects Dual NPN (default) or PNP; DIP switch B7 selects

N.O. (default) or N.C. operation; 150mA each
· Zone 1 output: white wire
· Zone 2 output: black wire

Output Protection

Protected against short circuit conditions

Response Time

DIP-switch-configurable ON/OFF response time

Indicators

Power LED: Green (power ON)
Signal Strength LED: Red, flashes in proportion to signal strength.

Steady on at 4x excess gain. Only indicates signal amplitude, not

target distance.
Output LEDs: Yellow (output energized) / Red (configuration)
See 

Overview 

on page 1

Adjustments

DIP-switch-configurable sensing distance, sensitivity, response time,

and output configuration

Construction

Housing: Polycarbonate
Lightpipes: Acrylic
Access Cap: Polyester

Operating Temperature

– 40° to + 65° C (– 40° to + 149° F)

Environmental Rating

IP67

Connections

Integral M12 Euro-style QD fitting. QD models require a mating cordset

Certifications

CMIIT Category G, FCC part 15, RSS-210, others pending

Beam Angles

SIDE

TOP

FCC ID: UE3Q240RAUS—This device complies with Part 15 of the FCC Rules. Operation is subject to the following two

conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received,

including interference that may cause undesired operation.

IC: 7044A-Q240RA—This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to

the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference,

including interference that may cause undesired operation of the device.

Cet appareil est conforme aux CNR exempts de licence d'Industrie Canada. Son fonctionnement est soumis aux deux

conditions suivantes: (1) Ce dispositif ne peut causer des interférences; et (2) Ce dispositif doit accepter toute

interférence, y compris les interférences qui peuvent entraîner un mauvais fonctionnement de l'appareil.

R-GAGE

 Q240RA-AF2 Sensor

 

 

P/N 184564 Rev. A

www.bannerengineering.com - Tel: +1-763-544-3164

5

Содержание R-GAGE Q240RA-AF2

Страница 1: ...ct Contact Banner Engineering for more information WARNING Not To Be Used for Personnel Protection Never use this device as a sensing device for personnel protection Doing so could lead to serious injury or death This device does not include the self checking redundant circuitry necessary to allow its use in personnel safety applications A sensor failure or malfunction can cause either an energize...

Страница 2: ... 3 5 m 11 5 ft Y Maximum Zone 1 setpoint distance 30 m 98 4 ft 30 m 98 4 ft A Minimum Zone 2 offset from Zone 1 2 m to 25 m 4 m 13 1 ft 5 5 m 18 0 ft B Maximum Zone 2 offset from Zone 1 2 m to 25 m 55 m 180 4 ft 55 m 180 4 ft D Dead Zone1 Sensor Configuration Use the included spanner to open the screw off cover on the side of the sensor and access the DIP switches Important Tighten the DIP switch ...

Страница 3: ...4 Distance CN US 0 0 0 0 2 m 6 6 ft 3 5 m 11 5 ft 0 0 0 1 2 5 m 8 2 ft 4 m 13 1 ft 0 0 1 0 3 m 9 8 ft 4 5 m 14 8 ft 0 0 1 1 3 5 m 11 5 ft 5 m 16 4 ft 0 1 0 0 4 m 13 1 ft 5 5 m 18 0 ft 0 1 0 1 5 m 16 4 ft 6 m 19 7 ft 0 1 1 0 6 m 19 7 ft 6 5 m 21 3 ft 0 1 1 1 7 m 23 0 ft 7 m 23 0 ft 1 0 0 0 8 m 26 2 ft 8 m 26 2 ft 1 0 0 1 10 m 32 8 ft 10 m 32 8 ft 1 0 1 0 12 m 39 4 ft 12 m 39 4 ft 1 0 1 1 14 m 45 9 ...

Страница 4: ...3 Sensitivity 0 0 0 8 Highest 0 0 1 7 0 1 0 6 High 0 1 1 5 1 0 0 4 Medium 1 0 1 3 1 1 0 2 Low 1 1 1 1 Lowest Default settings NOTE Operation at a high sensitivity not guaranteed for a zone set beyond 45 m 147 6 ft Output Configuration A8 NPN PNP 0 NPN 1 PNP Default settings B7 Normally Open Closed 0 NO 1 NC Response Speed B4 B5 B6 ON Total ms OFF Total ms Total ms 0 0 0 15 15 30 0 0 1 30 70 100 0 ...

Страница 5: ...d configuration See Overview on page 1 Adjustments DIP switch configurable sensing distance sensitivity response time and output configuration Construction Housing Polycarbonate Lightpipes Acrylic Access Cap Polyester Operating Temperature 40 to 65 C 40 to 149 F Environmental Rating IP67 Connections Integral M12 Euro style QD fitting QD models require a mating cordset Certifications CMIIT Category...

Страница 6: ...ar Large Truck Passenger Train 4 3 2 1 At sensitivity level 8 1 Weak Object Radar cross section 0 25 m2 2 Car Radar cross section 3 m2 3 Large Truck Radar cross section 50 m2 4 Passenger Train Radar cross section 300 m2 0 0 1 2 3 4 5 6 4 3 6 5 2 1 5 10 15 20 25 Meters 30 35 40 45 Meters Car Large Truck Passenger Train 4 3 2 Weak Object Trace Data 1 At sensitivity level 4 NOTE The effective beam pa...

Страница 7: ...repeat every 6 1 mm of distance between the sensor and the window The positions of maximum reflection from the window repeat between the minimums and decrease in effect until the window is approximately 150 mm 5 9 in away Consult the factory for pre tested window materials which can be used at any distance without issue Additionally the face of the window should be protected from flowing water and...

Страница 8: ...2 White 3 Blue 4 Black 5 Gray MQDEC2 515 4 57 m 15 ft MQDEC2 530 9 14 m 30 ft MQDEC2 550 15 2 m 50 ft MQDEC2 506RA 1 83 m 6 ft Right Angle 32 Typ 1 26 30 Typ 1 18 ø 14 5 0 57 M12 x 1 MQDEC2 515RA 4 57 m 15 ft MQDEC2 530RA 9 14 m 30 ft MQDEC2 550RA 15 2 m 50 ft NOTE Pin 5 is not used Brackets and Other Accessories SMBQ240SS2 Add on accessory to be used in conjunction with SMBQ240SS1 Provides 20 of ...

Страница 9: ... AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND WHETHER ARISING UNDER COURSE OF PERFORMANCE COURSE OF DEALING OR TRADE USAGE This Warranty is exclusive and limited to repair or at the discretion of Banner Engineering Corp replacement IN NO EVENT SHALL BANNER ENGINEERING CORP BE LIAB...

Отзывы: