Zone 2 Distance Offset from Zone 1
A5
A6
A7
Offset
0
0
0
2 m (6.6 ft)
0
0
1
4 m (13.1 ft)
0
1
0
6 m (19.7 ft)
0*
1*
1*
8 m (26.2 ft)
1
0
0
10 m (32.8 ft)
1
0
1
15 m (49.2 ft)
1
1
0
20 m (65.6 ft)
1
1
1
25 m (82.0 ft)
NOTE: Highest sensitivity is achieved only if the sensing distance is 36 m (118.1 ft) or less.
Sensitivity Selection
B1
B2
B3
Sensitivity
0
0
0
8 (Highest)
0
0
1
7...
0
1
0
6 (High)
0
1
1
5...
1 *
0 *
0 *
4 (Medium)
1
0
1
3...
1
1
0
2 (Low)
1
1
1
1 (Lowest)
* Default settings
NOTE: Operation at a high sensitivity not guaranteed for a zone set beyond 45 m (147.6 ft)
Output Configuration
A8
NPN / PNP
0*
NPN
1
PNP
* Default settings
B7
Normally Open / Closed
0*
NO
1
NC
Response Speed
B4
B5
B6
ON Total (ms)
OFF Total (ms)
Total (ms)
0
0
0
15
15
30
0
0
1
30
70
100
0
1
0
30
120
150
0*
1*
1*
50
300
350