DIP Switch Functions
Switches
Function
A1, A2, A3, A4
Zone 1 Distance (detects objects from sensor face to this point)
A5, A6, A7
Zone 2 Distance, Offset from Zone 1
A8
Polarity
B1, B2, B3
Sensitivity (higher sensitivity sees weaker objects and has a larger beam pattern)
B4, B5, B6
Response Speed
B7
Normally Open/Normally Closed output functionality
B8
Not Used
DIP switch 1 is on the left and DIP switch 8 is on the right.
Distance Settings
Zone 1 Distance
A1
A2
A3
A4
Distance
CN
US
0
0
0
0
2 m (6.6 ft)
3.5 m (11.5 ft)
0
0
0
1
2.5 m (8.2 ft)
4 m (13.1 ft)
0
0
1
0
3 m (9.8 ft)
4.5 m (14.8 ft)
0
0
1
1
3.5 m (11.5 ft)
5 m (16.4 ft)
0
1
0
0
4 m (13.1 ft)
5.5 m (18.0 ft)
0
1
0
1
5 m (16.4 ft)
6 m (19.7 ft)
0
1
1
0
6 m (19.7 ft)
6.5 m (21.3 ft)
0
1
1
1
7 m (23.0 ft)
7 m (23.0 ft)
1*
0*
0*
0*
8 m (26.2 ft)
8 m (26.2 ft)
1
0
0
1
10 m (32.8 ft)
10 m (32.8 ft)
1
0
1
0
12 m (39.4 ft)
12 m (39.4 ft)
1
0
1
1
14 m (45.9 ft)
14 m (45.9 ft)
1
1
0
0
16 m (52.5 ft)
16 m (52.5 ft)
1
1
0
1
20 m (65.6 ft)
20 m (65.6 ft)
1
1
1
0
25 m (82.0 ft)
25 m (82.0 ft)
1
1
1
1
30 m (98.4 ft)
30 m (98.4 ft)
* Default settings
R-GAGE
™
Q240RA-AF2 Sensor
P/N 184564 Rev. A