P/N 109027 rev. C

5

QS30 Series Diffuse-Mode Laser Sensor

Banner Engineering Corp. 

• 

Minneapolis, MN U.S.A.

www.bannerengineering.com  •  Tel: 763.544.3164

Sensor positions 

threshold midway 

between taught conditions

Darkest

(no signal)

Most Light

(saturated

signal)

Output OFF

Output ON

2nd Taught

Condition

1st Taught

Condition

Position

adjusted by

Manual Adjust

Figure 2. Two-Point TEACH (Light Operate

shown)

Two-Point Static TEACH

• Two-point TEACH
• Sets a single switching threshold
• Threshold is adjustable using  “+” and  “-” buttons (Manual Adjust)

Two-Point Static TEACH is the traditional setup method, used when two conditions
can be presented by the user. The sensor locates a single sensing threshold (the
switch point) midway between the two taught conditions, with the Output ON
condition on one side, and the Output OFF condition on the other (see Figure 2).

The first condition taught is the ON condition.The Output ON and OFF conditions can
be reversed by changing Light/Dark Operate status in SETUP mode.

Two-Point TEACH and Manual Adjust

Using Manual Adjust with Two-Point TEACH moves the switching threshold. The
lighted LED on the light bar will move to exhibit the relative amount of received signal.

Push Button

Remote Line

Display Shows

• Press and Hold

No action required; 
sensor is ready for
1st TEACH condition.

Power LED: OFF
Output LED: ON
Bargraph: #5 & 6 Flashing

Present Output ON
condition

• Click  

• Present Output ON

condition

• Single-pulse remote

line

Power LED: OFF
Output LED: OFF
Bargraph: #5 & 6 Flashing

Access

TEACH

Mode

Learn

Output

ON

Condition

Present Output
OFF condition

• Click  

• Present Output OFF

condition

• Single-pulse remote

line

Teach Accepted

Power LED: ON
Bargraph: One LED flashes to show

relative contrast (good contrast
shown; see table above)

Sensor returns to RUN mode

Learn

Output

OFF

Condition

Teach Unacceptable

Power LED: OFF
Bargraph: #1, 3, 6, 8 flash to show fail
Sensor returns to “Learn Output ON” 
condition

T

T

Bargraph

LED

Number

Relative Contrast/

Recommendation

6 to 8

Excellent:

Very stable operation.

4 to 5

Good:

Minor sensing variables will

not affect sensing reliability.

2 to 3

Low:

Minor sensing variables will

affect sensing reliability.

1

Marginal:  

Consider an alternate

sensing scheme.

Содержание QS30 Series

Страница 1: ...ntegral 5 pin Euro style QD QS30LDL Class 2 800 mm 32 Approx 1 mm at 800 mm 0 039 at 32 2 m 6 5 5 wire Cable QS30LDLQ Integral 5 pin Euro style QD Beam Pattern Supply Voltage 10 30V dc WARNING Not To Be Used for Personnel Protection Never use this product as a sensing device for personnel protection Doing so could lead to serious injury or death This product does NOT include the self checking redu...

Страница 2: ...reverse polarity over voltage and transient voltages Output Response Time 500 microseconds Indicators 8 segment red bargraph Signal strength relative to switch point Green LED Power ON Yellow LED Output conducting Construction ABS plastic housing acrylic lens cover Connections Environmental Rating IP67 NEMA 6 Delay at Power Up 1 second max outputs do not conduct during this time Output Protection ...

Страница 3: ... beam paths either above or below eye level where practical CAUTION Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure per EN 60825 Do NOT attempt to disassemble this sensor for repair A defective unit must be returned to the manufacturer Class 1 Lasers that are safe under reasonably foreseeable conditions of ope...

Страница 4: ...ntered on a single taught condition Single Point TEACH programming may be accomplished only statically Remote Programming The Remote Programming function may be used to program the sensor remotely or to disable the push buttons for security Connect the gray wire of the sensor to ground 0V dc with a remote programming switch connected between them Pulse the remote line according to the diagrams in ...

Страница 5: ...nt TEACH and Manual Adjust Using Manual Adjust with Two Point TEACH moves the switching threshold The lighted LED on the light bar will move to exhibit the relative amount of received signal Push Button Remote Line Display Shows Press and Hold No action required sensor is ready for 1st TEACH condition Power LED OFF Output LED ON Bargraph 5 6 Flashing Present Output ON condition Click Present Outpu...

Страница 6: ...e tuned whenever the sensor is in RUN mode by clicking the and buttons However when a manual adjustment is made the adaptive threshold system is disabled cancelled Push Button Remote Line Display Shows Press and Hold Hold remote line low to ground Power LED OFF Bargraph 7 8 flashing Present Output ON and OFF conditions Continue to hold Present Output ON and OFF conditions Continue to hold remote l...

Страница 7: ...anging Light Dark Operate status in SETUP mode Single Point TEACH programming may be accomplished only using Static TEACH The sensor learns a single sensing condition and adds switching thresholds above and below the taught condition to create a sensing window Single Point TEACH and Manual Adjust Using Manual Adjust with Single Point TEACH expands or contracts the size of the window The lighted LE...

Страница 8: ...icating return to RUN mode NOTES If SETUP mode programming is interrupted and remains inactive for 60 seconds the sensor returns to RUN mode with the most recent settings i e exits and saves current selection SETUP mode operates in the background while the outputs are active Manual Adjust Use during RUN mode accomplished via push buttons only Two Point TEACH Static or Dynamic Fine tunes sensing th...

Страница 9: ...s with 21 CFR 1040 10 and 1040 11 except for deviations pursuant to Laser Notice No 50 dated 7 26 01 32 5 mm 1 28 35 0 mm 1 38 QS30LD QS30LD 10 30 VDC 10 30 VDC 2 x ø3 3 mm 0 125 max torque 0 7 Nm 6 in lbs M30 x 1 5 Thread max torque 6 Nm 53 in lbs with included 30 mm mounting nut Dimensions QD Models Cabled Models Hookups Cabled Models QD Models bn Remote Teach bu wh bk gy 10 30V dc Load Load 150...

Страница 10: ...isconnect Cables 38 mm max 1 5 M12 x 1 ø 15 mm 0 6 38 mm max 1 5 Style Model Length Dimensions 5 pin Euro style straight MQDC1 506 MQDC1 515 MQDC1 530 2 m 6 5 5 m 15 9 m 30 M12 x 1 ø 15 mm 0 6 44 mm max 1 7 White Wire Blue Wire Black Wire Brown Wire Gray Wire Pin out 5 pin Euro style right angle MQDC1 506RA MQDC1 515RA MQDC1 530RA 2 m 6 5 5 m 15 9 m 30 ...

Страница 11: ... bracket for cable models Clearance for M4 8 hardware 12 tilt adjustment Heavy duty die cast bracket M18 vertical mounting option 8 tilt adjustment with cabled units Nuts and lockwasher included SMBQS30LT 14 gauge stainless steel for QD models with right angle cables Tall right angle mounting bracket 8 Tilt adjustment 64 4mm 2 54 1 9mm 0 07 4 5mm 0 18 24 0mm 0 95 11 0mm 0 43 ø4 3mm ø0 17 44 0mm 1 ...

Страница 12: ...ound to be defective at the time it is returned to the factory during the warranty period This warranty does not cover damage or liability for the improper application of Banner products This warranty is in lieu of any other warranty either expressed or implied P N 109027 rev C Banner Engineering Corp 9714 Tenth Ave No Minneapolis MN USA 55441 Phone 763 544 3164 www bannerengineering com Email sen...

Отзывы: