background image

QS30 Series Diffuse-Mode Laser Sensor

4

P/N 109027 rev. C

Banner Engineering Corp. 

• 

Minneapolis, MN U.S.A.

www.bannerengineering.com  •  Tel: 763.544.3164

Sensor Programming 

Sensor configuration is accomplished through TEACH-mode programming and
SETUP mode. After TEACH mode has defined the sensing parameters, SETUP mode
may be used to add an OFF-delay or change the light/dark operate status. Manual
Adjust may be used to fine-tune the thresholds (see page 7). Two push buttons,
Dynamic (+) and Static (-), or the remote wire, may be used to access and set
programming parameters.

Sensor programming may be accomplished using any of three TEACH methods. A
single switching threshold may be programmed using either dynamic (on-the-fly) or
static TEACH. In addition, Single-Point Static TEACH may be used to define a sensing
window, centered on a single taught condition. Single-Point TEACH programming
may be accomplished only statically. 

Remote Programming

The Remote Programming function may be used to program the sensor remotely or to
disable the push buttons for security. Connect the gray wire of the sensor to ground
(0V dc), with a remote programming switch connected between them. Pulse the remote
line according to the diagrams in the programming procedures. The length of the
individual programming pulses is equal to the value T:

0.04 seconds  

0.8 seconds

Returning to RUN Mode

TEACH and SETUP modes each may be exited either after the 60-second time-out, or
by exiting (cancelling out of) the process:

• In Static TEACH mode, press and hold the Static (-) button (or hold the remote line)

for 2 seconds to exit. The sensor returns to RUN mode without saving any new
settings.  

• In SETUP mode, press and hold both the Static (-) and Dynamic (+) buttons (or hold

the remote line) for 2 seconds to exit. The sensor returns to RUN mode and saves
the current setting.

Содержание QS30 Series

Страница 1: ...ntegral 5 pin Euro style QD QS30LDL Class 2 800 mm 32 Approx 1 mm at 800 mm 0 039 at 32 2 m 6 5 5 wire Cable QS30LDLQ Integral 5 pin Euro style QD Beam Pattern Supply Voltage 10 30V dc WARNING Not To Be Used for Personnel Protection Never use this product as a sensing device for personnel protection Doing so could lead to serious injury or death This product does NOT include the self checking redu...

Страница 2: ...reverse polarity over voltage and transient voltages Output Response Time 500 microseconds Indicators 8 segment red bargraph Signal strength relative to switch point Green LED Power ON Yellow LED Output conducting Construction ABS plastic housing acrylic lens cover Connections Environmental Rating IP67 NEMA 6 Delay at Power Up 1 second max outputs do not conduct during this time Output Protection ...

Страница 3: ... beam paths either above or below eye level where practical CAUTION Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure per EN 60825 Do NOT attempt to disassemble this sensor for repair A defective unit must be returned to the manufacturer Class 1 Lasers that are safe under reasonably foreseeable conditions of ope...

Страница 4: ...ntered on a single taught condition Single Point TEACH programming may be accomplished only statically Remote Programming The Remote Programming function may be used to program the sensor remotely or to disable the push buttons for security Connect the gray wire of the sensor to ground 0V dc with a remote programming switch connected between them Pulse the remote line according to the diagrams in ...

Страница 5: ...nt TEACH and Manual Adjust Using Manual Adjust with Two Point TEACH moves the switching threshold The lighted LED on the light bar will move to exhibit the relative amount of received signal Push Button Remote Line Display Shows Press and Hold No action required sensor is ready for 1st TEACH condition Power LED OFF Output LED ON Bargraph 5 6 Flashing Present Output ON condition Click Present Outpu...

Страница 6: ...e tuned whenever the sensor is in RUN mode by clicking the and buttons However when a manual adjustment is made the adaptive threshold system is disabled cancelled Push Button Remote Line Display Shows Press and Hold Hold remote line low to ground Power LED OFF Bargraph 7 8 flashing Present Output ON and OFF conditions Continue to hold Present Output ON and OFF conditions Continue to hold remote l...

Страница 7: ...anging Light Dark Operate status in SETUP mode Single Point TEACH programming may be accomplished only using Static TEACH The sensor learns a single sensing condition and adds switching thresholds above and below the taught condition to create a sensing window Single Point TEACH and Manual Adjust Using Manual Adjust with Single Point TEACH expands or contracts the size of the window The lighted LE...

Страница 8: ...icating return to RUN mode NOTES If SETUP mode programming is interrupted and remains inactive for 60 seconds the sensor returns to RUN mode with the most recent settings i e exits and saves current selection SETUP mode operates in the background while the outputs are active Manual Adjust Use during RUN mode accomplished via push buttons only Two Point TEACH Static or Dynamic Fine tunes sensing th...

Страница 9: ...s with 21 CFR 1040 10 and 1040 11 except for deviations pursuant to Laser Notice No 50 dated 7 26 01 32 5 mm 1 28 35 0 mm 1 38 QS30LD QS30LD 10 30 VDC 10 30 VDC 2 x ø3 3 mm 0 125 max torque 0 7 Nm 6 in lbs M30 x 1 5 Thread max torque 6 Nm 53 in lbs with included 30 mm mounting nut Dimensions QD Models Cabled Models Hookups Cabled Models QD Models bn Remote Teach bu wh bk gy 10 30V dc Load Load 150...

Страница 10: ...isconnect Cables 38 mm max 1 5 M12 x 1 ø 15 mm 0 6 38 mm max 1 5 Style Model Length Dimensions 5 pin Euro style straight MQDC1 506 MQDC1 515 MQDC1 530 2 m 6 5 5 m 15 9 m 30 M12 x 1 ø 15 mm 0 6 44 mm max 1 7 White Wire Blue Wire Black Wire Brown Wire Gray Wire Pin out 5 pin Euro style right angle MQDC1 506RA MQDC1 515RA MQDC1 530RA 2 m 6 5 5 m 15 9 m 30 ...

Страница 11: ... bracket for cable models Clearance for M4 8 hardware 12 tilt adjustment Heavy duty die cast bracket M18 vertical mounting option 8 tilt adjustment with cabled units Nuts and lockwasher included SMBQS30LT 14 gauge stainless steel for QD models with right angle cables Tall right angle mounting bracket 8 Tilt adjustment 64 4mm 2 54 1 9mm 0 07 4 5mm 0 18 24 0mm 0 95 11 0mm 0 43 ø4 3mm ø0 17 44 0mm 1 ...

Страница 12: ...ound to be defective at the time it is returned to the factory during the warranty period This warranty does not cover damage or liability for the improper application of Banner products This warranty is in lieu of any other warranty either expressed or implied P N 109027 rev C Banner Engineering Corp 9714 Tenth Ave No Minneapolis MN USA 55441 Phone 763 544 3164 www bannerengineering com Email sen...

Отзывы: