![Banner Q5X Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/banner/q5x/q5x_reference-manual_3722377007.webp)
Index
Sub-
index
Name
Length
Value Range
Default
Access
Rights
Data
Storage?
Smart Sensor
Profile?
AOI
71
2
Far Frequency
32-bit integer
The frequency corresponding to a
target at the far limit of the sensing
range
100 Hz – 45000 Hz
600 Hz
rw
y
72
Display String
72
1
Line 1
5-octet String
US_ASCII
ro
73-75
unused/reserved
76
All-Time Run Time Event
Time
76
1
Event Time
32-bit integer
0–2147483647
0
rw
y
77
Resettable Run Time Event
Time
77
1
Event Time
32-bit integer
0-2147483647
0
rw
y
IO-Link Events
Events are acyclic transmissions from the IO-Link device to the IO-Link master. Events can be error messages and/or warning or
maintenance data.
Code
Type
Description
25376 (0×6320)
Error
Parameter error (check datasheet and values)
36000 (0×8CA0)
Warning
All-time Run Time Event (Event indicating the corresponding configured running time has elapsed.)
36001 (0×8CA1)
Warning
Resettable Run Time Event (Event indicating the corresponding configured running time has
elapsed.)
36003 (0×8CA3)
Notification
Teach Completed Event (Event indicating a teach has been completed.)
36004 (0×8CA4)
Notification
Factory Settings Restored Event (Event indicating that the factory settings have been restored.)
36005 (0×8CA5)
Notification
Teach Coerced Event (Event indicating a taught condition resulting in a setpoint being coerced.
Taught was updated.)
36007 (0×8CA7)
Notification
Teach Failed Event (Event indicating an invalid target condition was attempted to be taught. Taught
setpoint was not updated.)
36096 (0×8d00)
Error
Laser fault event (laser shut down for safety)
36097 (0×8D01)
Error
System Fault Event (Contact Banner Engineering to resolve.)
IO-Link Data Reference Guide: Q5X Sensor
©
Banner Engineering Corp. All rights reserved