Banner Q5X Скачать руководство пользователя страница 7

Index

Sub-

index

Name

Length

Value Range

Default

Access

Rights

Data

Storage?

Smart Sensor

Profile?

AOI

71

2

Far Frequency

32-bit integer

The frequency corresponding to a
target at the far limit of the sensing
range

100 Hz – 45000 Hz

600 Hz

rw

y

72

Display String

72

1

Line 1

5-octet String
US_ASCII

ro

73-75

unused/reserved

76

All-Time Run Time Event
Time

76

1

Event Time

32-bit integer

0–2147483647

0

rw

y

77

Resettable Run Time Event
Time

77

1

Event Time

32-bit integer

0-2147483647

0

rw

y

IO-Link Events

Events are acyclic transmissions from the IO-Link device to the IO-Link master. Events can be error messages and/or warning or

maintenance data.

Code

Type

Description

25376 (0×6320)

Error

Parameter error (check datasheet and values)

36000 (0×8CA0)

Warning

All-time Run Time Event (Event indicating the corresponding configured running time has elapsed.)

36001 (0×8CA1)

Warning

Resettable Run Time Event (Event indicating the corresponding configured running time has
elapsed.)

36003 (0×8CA3)

Notification

Teach Completed Event (Event indicating a teach has been completed.)

36004 (0×8CA4)

Notification

Factory Settings Restored Event (Event indicating that the factory settings have been restored.)

36005 (0×8CA5)

Notification

Teach Coerced Event (Event indicating a taught condition resulting in a setpoint being coerced.
Taught was updated.)

36007 (0×8CA7)

Notification

Teach Failed Event (Event indicating an invalid target condition was attempted to be taught. Taught
setpoint was not updated.)

36096 (0×8d00)

Error

Laser fault event (laser shut down for safety)

36097 (0×8D01)

Error

System Fault Event (Contact Banner Engineering to resolve.)

 

 

IO-Link Data Reference Guide: Q5X Sensor

 

©

 Banner Engineering Corp. All rights reserved

 

Содержание Q5X

Страница 1: ...smitted cyclically to the IO Link master from the IO Link device Process Data If Binary Data Is Included Process Data Input Subindex Name Number of Bits Data Values 1 Channel 1 Output State 1 0 inacti...

Страница 2: ...election Octet 0 Subindex 2 2 2 2 2 2 2 2 Bit offset 31 30 29 28 27 26 25 24 Value 0 0 0 0 0 0 1 1 Octet 1 Subindex 2 2 2 2 2 1 1 1 Bit offset 23 22 21 20 19 18 17 16 Value 0 1 0 0 1 0 1 1 Octet 2 Sub...

Страница 3: ...mmand 65 SP1 Single Value Teach 67 SP1 Two Value Teach TP1 68 SP1 Two Value Teach TP2 71 SP1 Dynamic Teach Start 72 SP1 Dynamic Teach Stop 79 SP1 Teach Exit 160 Laser Disable 161 Laser Enable 130 Rest...

Страница 4: ...cessful 1 successfully taught ro y 60 BDC1 Setpoints 60 1 BDC1 Setpoint SP1 32 bit integer 95 mm 2000 mm 250 mm rw y y 60 2 BDC1 Setpoint SP2 32 bit integer 0 mm for all teach modes except One Point W...

Страница 5: ...eger 0 On 1 On Inverted 2 Off 3 Off Inverted 0 rw y 64 7 Pushbutton Lockout 8 bit integer 0 No Lockout 1 Pushbuttons Locked 2 Operator Lockout 0 rw y 64 8 Output Polarity 8 bit integer 0 Default 1 PNP...

Страница 6: ...16 bit integer 1905 mm 1905 mm 0 mm rw y 66 7 BDC2 FGS User Window Size 16 bit integer 0 mm 1905 mm 0 mm rw y 66 8 BDC2 Auto Thresholding 8 bit integer 0 On 1 Off 2 High Speed 1 rw y 67 Status 67 1 Me...

Страница 7: ...arning All time Run Time Event Event indicating the corresponding configured running time has elapsed 36001 0 8CA1 Warning Resettable Run Time Event Event indicating the corresponding configured runni...

Отзывы: