Banner Q5X Скачать руководство пользователя страница 3

Octet 0

Subindex

Reserved

Reserved

Reserved

Reserved

Reserved

Reserved

Reserved

1

Bit offset

7

6

5

4

3

2

1

0

Value

0

0

0

0

0

0

0

1

Example Based on the Value Above

Transducer Disable = 1 (Inactive)

Parameters Set Using IO-Link

These parameters can be read from and/or written to an IO-Link model of the Q5X Laser sensor. Also included is information about

whether the variable in question is saved during Data Storage and whether the variable came from the IO-Link Smart Sensor

Profile.
Unlike Process Data In, which is transmitted from the IO-Link device to the IO-Link master cyclically, these parameters are read or

written acyclically as needed.

Index

Sub-

index

Name

Length

Value Range

Default

Access

Rights

Data

Storage?

Smart Sensor

Profile?

AOI

0

1–16 Direct Parameter Page 1

(incl. Vendor ID & Device ID)

ro

1

1–16 Direct Parameters Page 2

rw

2

Standard Command

65 = SP1 Single Value Teach
67 = SP1 Two Value Teach TP1
68 = SP1 Two Value Teach TP2
71 = SP1 Dynamic Teach Start
72 = SP1 Dynamic Teach Stop
79 = SP1 Teach Exit
160 = Laser Disable
161 = Laser Enable
130 = Restore Factory Settings
162 = Start discovery
163 = Stop discovery

wo

y

3

Data Storage Index (device-
specific list of parameters to
be stored)

rw

4–11

reserved by IO-Link
Specification

12

Device Access Locks

12

1

Parameter Write Access
Lock

0 = off
1 = on

0

rw

y

12

2

Data Storage Lock

0 = off
1 = on

0

rw

y

12

3

Local Parameterization Lock

0 = off
1 = on

0

rw

y

12

4

Local User Interface Lock

0 = off
1 = on

0

rw

y

13

Profile Characteristic

ro

14

PDInput Descriptor

ro

15

PDOutput Descriptor

ro

16

Vendor Name string

Banner Engineering Corporation

ro

17

Vendor Text string

More Sensors. More Solutions.

ro

18

Product Name string

Q5X

ro

19

Product ID string

Q5XKLAF2000-Q8

ro

20

Product Text string

Laser Measurement Sensor

ro

y

21

Serial Number

ro

22

unused/reserved

ro

IO-Link Data Reference Guide: Q5X Sensor

 

 

P/N 206834 Rev. B

www.bannerengineering.com - Tel: + 1 888 373 6767

3

Содержание Q5X

Страница 1: ...smitted cyclically to the IO Link master from the IO Link device Process Data If Binary Data Is Included Process Data Input Subindex Name Number of Bits Data Values 1 Channel 1 Output State 1 0 inacti...

Страница 2: ...election Octet 0 Subindex 2 2 2 2 2 2 2 2 Bit offset 31 30 29 28 27 26 25 24 Value 0 0 0 0 0 0 1 1 Octet 1 Subindex 2 2 2 2 2 1 1 1 Bit offset 23 22 21 20 19 18 17 16 Value 0 1 0 0 1 0 1 1 Octet 2 Sub...

Страница 3: ...mmand 65 SP1 Single Value Teach 67 SP1 Two Value Teach TP1 68 SP1 Two Value Teach TP2 71 SP1 Dynamic Teach Start 72 SP1 Dynamic Teach Stop 79 SP1 Teach Exit 160 Laser Disable 161 Laser Enable 130 Rest...

Страница 4: ...cessful 1 successfully taught ro y 60 BDC1 Setpoints 60 1 BDC1 Setpoint SP1 32 bit integer 95 mm 2000 mm 250 mm rw y y 60 2 BDC1 Setpoint SP2 32 bit integer 0 mm for all teach modes except One Point W...

Страница 5: ...eger 0 On 1 On Inverted 2 Off 3 Off Inverted 0 rw y 64 7 Pushbutton Lockout 8 bit integer 0 No Lockout 1 Pushbuttons Locked 2 Operator Lockout 0 rw y 64 8 Output Polarity 8 bit integer 0 Default 1 PNP...

Страница 6: ...16 bit integer 1905 mm 1905 mm 0 mm rw y 66 7 BDC2 FGS User Window Size 16 bit integer 0 mm 1905 mm 0 mm rw y 66 8 BDC2 Auto Thresholding 8 bit integer 0 On 1 Off 2 High Speed 1 rw y 67 Status 67 1 Me...

Страница 7: ...arning All time Run Time Event Event indicating the corresponding configured running time has elapsed 36001 0 8CA1 Warning Resettable Run Time Event Event indicating the corresponding configured runni...